These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 32459032)

  • 1. Genetic algorithm search for the worst-case MRI RF exposure for a multiconfiguration implantable fixation system modeled using artificial neural networks.
    Zheng J; Lan Q; Kainz W; Long SA; Chen J
    Magn Reson Med; 2020 Nov; 84(5):2754-2764. PubMed ID: 32459032
    [TBL] [Abstract][Full Text] [Related]  

  • 2. On the estimation of the worst-case implant-induced RF-heating in multi-channel MRI.
    Córcoles J; Zastrow E; Kuster N
    Phys Med Biol; 2017 Jun; 62(12):4711-4727. PubMed ID: 28252443
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Finite volume analysis of temperature effects induced by active MRI implants: 2. Defects on active MRI implants causing hot spots.
    Busch MH; Vollmann W; Grönemeyer DH
    Biomed Eng Online; 2006 May; 5():35. PubMed ID: 16729878
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of Device Configuration and Patient's Body Composition on the RF Heating and Nonsusceptibility Artifact of Deep Brain Stimulation Implants During MRI at 1.5T and 3T.
    Bhusal B; Nguyen BT; Sanpitak PP; Vu J; Elahi B; Rosenow J; Nolt MJ; Lopez-Rosado R; Pilitsis J; DiMarzio M; Golestanirad L
    J Magn Reson Imaging; 2021 Feb; 53(2):599-610. PubMed ID: 32860322
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Wire-based sternal closure: MRI-related heating at 1.5 T/64 MHz and 3 T/128 MHz based on simulation and experimental phantom study.
    Zheng J; Xia M; Kainz W; Chen J
    Magn Reson Med; 2020 Mar; 83(3):1055-1065. PubMed ID: 31468593
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Device Configuration and Patient's Body Composition Significantly Affect RF Heating of Deep Brain Stimulation Implants During MRI: An Experimental Study at 1.5T and 3T.
    Bhusal B; Nguyen BT; Vu J; Elahi B; Rosenow J; Nolt MJ; Pilitsis J; DiMarzio M; Golestanirad L
    Annu Int Conf IEEE Eng Med Biol Soc; 2020 Jul; 2020():5192-5197. PubMed ID: 33019155
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Reducing MRI RF-induced heating for the external fixation using capacitive structures.
    Zheng J; Yang R; Wang Q; Guo R; Xu J; Shou X; Kainz W; Chen J
    Phys Med Biol; 2020 Aug; 65(15):155017. PubMed ID: 32460252
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Adaptive SAR mass-averaging framework to improve predictions of local RF heating near a hip implant for parallel transmit at 7 T.
    Destruel A; O'Brien K; Jin J; Liu F; Barth M; Crozier S
    Magn Reson Med; 2019 Jan; 81(1):615-627. PubMed ID: 30058186
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Application of Multilayer Perceptron Genetic Algorithm Neural Network in Chinese-English Parallel Corpus Noise Processing.
    Li B; Tuo A; Kong H; Liu S; Chen J
    Comput Intell Neurosci; 2021; 2021():7144635. PubMed ID: 34966422
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A numerical and experimental study of RF shimming in the presence of hip prostheses using adaptive SAR at 3 T.
    Destruel A; Fuentes M; Weber E; O'Brien K; Jin J; Liu F; Barth M; Crozier S
    Magn Reson Med; 2019 Jun; 81(6):3826-3839. PubMed ID: 30803001
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Computational and experimental investigation of RF-induced heating for multiple orthopedic implants.
    Guo R; Zheng J; Wang Y; Zeng Q; Wang Q; Yang R; Kainz W; Chen J
    Magn Reson Med; 2019 Nov; 82(5):1848-1858. PubMed ID: 31183897
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Scan-specific robust artificial-neural-networks for k-space interpolation (RAKI) reconstruction: Database-free deep learning for fast imaging.
    Akçakaya M; Moeller S; Weingärtner S; Uğurbil K
    Magn Reson Med; 2019 Jan; 81(1):439-453. PubMed ID: 30277269
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Real-time assessment of potential peak local specific absorption rate value without phase monitoring: Trigonometric maximization method for worst-case local specific absorption rate determination.
    Meliadò EF; Sbrizzi A; van den Berg CAT; Luijten PR; Raaijmakers AJE
    Magn Reson Med; 2021 Jun; 85(6):3420-3433. PubMed ID: 33350525
    [TBL] [Abstract][Full Text] [Related]  

  • 14. RF tissue-heating near metallic implants during magnetic resonance examinations: an approach in the ac limit.
    Ballweg V; Eibofner F; Graf H
    Med Phys; 2011 Oct; 38(10):5522-9. PubMed ID: 21992370
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Magnetic resonance imaging with implanted neurostimulators: numerical calculation of the induced heating.
    Golombeck MA; Thiele J; Dössel O
    Biomed Tech (Berl); 2002; 47 Suppl 1 Pt 2():660-3. PubMed ID: 12465267
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Modeling of electrodes and implantable pulse generator cases for the analysis of implant tip heating under MR imaging.
    Acikel V; Uslubas A; Atalar E
    Med Phys; 2015 Jul; 42(7):3922-31. PubMed ID: 26133593
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evolutionary artificial neural networks by multi-dimensional particle swarm optimization.
    Kiranyaz S; Ince T; Yildirim A; Gabbouj M
    Neural Netw; 2009 Dec; 22(10):1448-62. PubMed ID: 19556105
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accelerated coronary MRI with sRAKI: A database-free self-consistent neural network k-space reconstruction for arbitrary undersampling.
    Hosseini SAH; Zhang C; Weingärtner S; Moeller S; Stuber M; Ugurbil K; Akçakaya M
    PLoS One; 2020; 15(2):e0229418. PubMed ID: 32084235
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effects of patient orientations, landmark positions, and device positions on the MRI RF-induced heating for modular external fixation devices.
    Xia M; Zheng J; Yang R; Song S; Xu J; Liu Q; Kainz W; Long SA; Chen J
    Magn Reson Med; 2021 Mar; 85(3):1669-1680. PubMed ID: 32970911
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pregnant women models analyzed for RF exposure and temperature increase in 3T RF shimmed birdcages.
    Murbach M; Neufeld E; Samaras T; Córcoles J; Robb FJ; Kainz W; Kuster N
    Magn Reson Med; 2017 May; 77(5):2048-2056. PubMed ID: 27174499
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.