242 related articles for article (PubMed ID: 32466868)
1. Finite element analysis of narrow dental implants.
Valera-Jiménez JF; Burgueño-Barris G; Gómez-González S; López-López J; Valmaseda-Castellón E; Fernández-Aguado E
Dent Mater; 2020 Jul; 36(7):927-935. PubMed ID: 32466868
[TBL] [Abstract][Full Text] [Related]
2. Finite element analysis of stress distribution with splinted and nonsplinted maxillary anterior fixed prostheses supported by zirconia or titanium implants.
Bal BT; Cağlar A; Aydin C; Yilmaz H; Bankoğlu M; Eser A
Int J Oral Maxillofac Implants; 2013; 28(1):e27-38. PubMed ID: 23377079
[TBL] [Abstract][Full Text] [Related]
3. Three-dimensional finite element analysis of two angled narrow-diameter implant designs for an all-on-4 prosthesis.
Moreira de Melo EJ; Francischone CE
J Prosthet Dent; 2020 Oct; 124(4):477-484. PubMed ID: 31810614
[TBL] [Abstract][Full Text] [Related]
4. Implant-bone load transfer mechanisms in complete-arch prostheses supported by four implants: a three-dimensional finite element approach.
Baggi L; Pastore S; Di Girolamo M; Vairo G
J Prosthet Dent; 2013 Jan; 109(1):9-21. PubMed ID: 23328192
[TBL] [Abstract][Full Text] [Related]
5. A Three-Dimensional Finite Element Analysis of the Stress Distribution Generated by Splinted and Nonsplinted Prostheses in the Rehabilitation of Various Bony Ridges with Regular or Short Morse Taper Implants.
Toniollo MB; Macedo AP; Rodrigues RC; Ribeiro RF; de Mattos MG
Int J Oral Maxillofac Implants; 2017; 32(2):372-376. PubMed ID: 28291862
[TBL] [Abstract][Full Text] [Related]
6. Finite Element Analysis of Bone Stress in the Posterior Mandible Using Regular and Short Implants, in the Same Context, with Splinted and Nonsplinted Prostheses.
Toniollo MB; Macedo AP; Pupim D; Zaparolli D; da Gloria Chiarello de Mattos M
Int J Oral Maxillofac Implants; 2017; 32(4):e199-e206. PubMed ID: 28708912
[TBL] [Abstract][Full Text] [Related]
7. Comparative evaluation of the effect of diameter, length and number of implants supporting three-unit fixed partial prostheses on stress distribution in the bone.
Iplikçioğlu H; Akça K
J Dent; 2002 Jan; 30(1):41-6. PubMed ID: 11741734
[TBL] [Abstract][Full Text] [Related]
8. Three-dimensional finite element analysis of fixed complete-arch prostheses supported by 4 immediate-loaded implants in the completely edentulous maxilla using clinical computerized tomography data.
Kimura K; Fukase Y; Makino M; Masaki C; Nakamoto T; Hosokawa R
J Oral Implantol; 2011 Mar; 37 Spec No():96-105. PubMed ID: 21495797
[TBL] [Abstract][Full Text] [Related]
9. Narrow- and regular-diameter implants in the posterior region of the jaws to support single crowns: A 3-year split-mouth randomized clinical trial.
de Souza AB; Sukekava F; Tolentino L; César-Neto JB; Garcez-Filho J; Araújo MG
Clin Oral Implants Res; 2018 Jan; 29(1):100-107. PubMed ID: 28994192
[TBL] [Abstract][Full Text] [Related]
10. Comparative evaluation of short or standard implants with different prosthetic designs in the posterior mandibular region: a three-dimensional finite element analysis study.
Qin S; Gao Z
Comput Methods Biomech Biomed Engin; 2023 Sep; 26(12):1499-1509. PubMed ID: 36125258
[TBL] [Abstract][Full Text] [Related]
11. Splinted and Nonsplinted Crowns with Different Implant Lengths in the Posterior Maxilla by Three-Dimensional Finite Element Analysis.
Lemos CAA; Verri FR; Santiago Junior JF; de Souza Batista VE; Kemmoku DT; Noritomi PY; Pellizzer EP
J Healthc Eng; 2018; 2018():3163096. PubMed ID: 30254726
[TBL] [Abstract][Full Text] [Related]
12. Effect of Splinting of Tilted External Hexagon Implants on 3-Unit Implant-Supported Prostheses in the Posterior Maxilla: A 3D Finite Element Analysis.
de Faria Almeida DA; Verri FR; Lemos CAA; de Souza Batista VE; Santiago Júnior JF; Rosa CDDRD; Noritomi PY; Pellizzer EP
J Prosthodont; 2022 Oct; 31(8):697-704. PubMed ID: 34859540
[TBL] [Abstract][Full Text] [Related]
13. Platform switching: biomechanical evaluation using three-dimensional finite element analysis.
Tabata LF; Rocha EP; Barão VA; Assunção WG
Int J Oral Maxillofac Implants; 2011; 26(3):482-91. PubMed ID: 21691594
[TBL] [Abstract][Full Text] [Related]
14. Finite element analysis of implant-supported prosthesis with pontic and cantilever in the posterior maxilla.
de Souza Batista VE; Verri FR; Almeida DA; Santiago Junior JF; Lemos CA; Pellizzer EP
Comput Methods Biomech Biomed Engin; 2017 May; 20(6):663-670. PubMed ID: 28349769
[TBL] [Abstract][Full Text] [Related]
15. A 3D Finite Element Analysis of Bone Tissue in 3-Unit Implant-Supported Prostheses: Effect of Splinting Factor and Implant Length and Diameter.
de Souza Batista VE; Verri FR; Lemos CA; Cruz RS; Noritomi PY; Pellizzer EP
Eur J Prosthodont Restor Dent; 2021 Feb; 29(2):76-83. PubMed ID: 33146474
[TBL] [Abstract][Full Text] [Related]
16. Stress and Strain Distribution Patterns in Bone around Splinted Standard and Short Implants Placed at the Crestal Level and Subcrestally using Three- Dimensional Finite Element Analysis.
Amid R; Rasoolzadeh RA; Motlagh AM; Dehnavi F; Kadkhodazadeh M
J Long Term Eff Med Implants; 2017; 27(1):1-11. PubMed ID: 29604944
[TBL] [Abstract][Full Text] [Related]
17. Effects of splinted prosthesis supported a wide implant or two implants: a three-dimensional finite element analysis.
Huang HL; Huang JS; Ko CC; Hsu JT; Chang CH; Chen MY
Clin Oral Implants Res; 2005 Aug; 16(4):466-72. PubMed ID: 16117772
[TBL] [Abstract][Full Text] [Related]
18. The Clinical Performance of Narrow Diameter Implants Versus Regular Diameter Implants: A Meta-Analysis.
Ma M; Qi M; Zhang D; Liu H
J Oral Implantol; 2019 Dec; 45(6):503-508. PubMed ID: 31536434
[TBL] [Abstract][Full Text] [Related]
19. Comparison of stress distribution in partially and completely edentulous mandibles around splinted and non-splinted implant prostheses: A finite element study.
Ozeki K; Nishio H
Biomed Mater Eng; 2020; 31(1):19-33. PubMed ID: 32083566
[TBL] [Abstract][Full Text] [Related]
20. Tilting of splinted implants for improved prosthodontic support: a two-dimensional finite element analysis.
Zampelis A; Rangert B; Heijl L
J Prosthet Dent; 2007 Jun; 97(6 Suppl):S35-43. PubMed ID: 17618932
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]