158 related articles for article (PubMed ID: 32467178)
1. Data Mining to Determine the Influence of Fluid Properties on the Integrity Test Values.
Thome B; Joseph B; Dassu D; Gaerke J; McBurnie L; Dixit M; Stering M; Tomlinson S; Mills S; Ferrante S; Weitzmann C
PDA J Pharm Sci Technol; 2020; 74(5):524-562. PubMed ID: 32467178
[TBL] [Abstract][Full Text] [Related]
2. Test Process and Results of Potential Masking of Sterilizing-Grade Filters.
Ferrante S; McBurnie L; Dixit M; Joseph B; Jornitz M
PDA J Pharm Sci Technol; 2020; 74(5):509-523. PubMed ID: 32467175
[TBL] [Abstract][Full Text] [Related]
3. Preuse/Poststerilization Integrity Testing (PUPSIT): To Do or Not to Do?
Gupta VS; Jindal J; Gupta A; Gupta NK
PDA J Pharm Sci Technol; 2020; 74(3):301-308. PubMed ID: 31732690
[TBL] [Abstract][Full Text] [Related]
4. Evaluation of the Effect of the Volume Throughput and Maximum Flux of Low-Surface-Tension Fluids on Bacterial Penetration of 0.2 Micron-Rated Filters during Process-Specific Filter Validation Testing.
Folmsbee M
PDA J Pharm Sci Technol; 2015; 69(2):307-16. PubMed ID: 25868996
[TBL] [Abstract][Full Text] [Related]
5. Basics of sterile compounding: bubble point testing.
Thoma L
Int J Pharm Compd; 2014; 18(1):54-7. PubMed ID: 24881342
[TBL] [Abstract][Full Text] [Related]
6. Scale-up of Sterilizing-grade Membrane Filters from Discs to Pleated Cartridges: Effects of Operating Parameters and Solution Properties.
Kumar A; Martin J; Kuriyel R
PDA J Pharm Sci Technol; 2015; 69(1):74-87. PubMed ID: 25691716
[TBL] [Abstract][Full Text] [Related]
7. Application of membrane filtration for removal of diminutive bioburden organisms in pharmaceutical products and processes.
Sundaram S; Auriemma M; Howard G; Brandwein H; Leo F
PDA J Pharm Sci Technol; 1999; 53(4):186-201. PubMed ID: 10754712
[TBL] [Abstract][Full Text] [Related]
8. Impact of tubing material on the failure of product-specific bubble points of sterilizing-grade filters.
Meyer BK; Vargas D
PDA J Pharm Sci Technol; 2006; 60(4):248-53. PubMed ID: 17089693
[TBL] [Abstract][Full Text] [Related]
9. The Development of a Microbial Challenge Test with Acholeplasma laidlawii To Rate Mycoplasma-Retentive Filters by Filter Manufacturers.
Folmsbee M; Lentine KR; Wright C; Haake G; Mcburnie L; Ashtekar D; Beck B; Hutchison N; Okhio-Seaman L; Potts B; Pawar V; Windsor H
PDA J Pharm Sci Technol; 2014; 68(3):281-96. PubMed ID: 25188349
[TBL] [Abstract][Full Text] [Related]
10. The Water Pressure Integrity Test--a new integrity test for hydrophobic membrane filters.
Dosmar M; Wolber P; Bracht K; Tröger H; Waibel P
J Parenter Sci Technol; 1992; 46(4):102-6. PubMed ID: 1453277
[TBL] [Abstract][Full Text] [Related]
11. Evaluation of the bubble point test of a 0.22-μm membrane filter used for the sterilizing filtration of PET radiopharmaceuticals.
Hayashi K; Douhara K; Kashino G
Ann Nucl Med; 2014 Jul; 28(6):586-92. PubMed ID: 24610680
[TBL] [Abstract][Full Text] [Related]
12. Sorption of bacterial endotoxin and retention of bacteria by positively charged membrane filters.
van Doorne H
J Parenter Sci Technol; 1993; 47(5):192-8. PubMed ID: 8263658
[TBL] [Abstract][Full Text] [Related]
13. Membrane filtration of pharmaceutical solutions.
McKinnon BT; Avis KE
Am J Hosp Pharm; 1993 Sep; 50(9):1921-36. PubMed ID: 8135243
[TBL] [Abstract][Full Text] [Related]
14. Use of pressure-hold test for sterilizing filter membrane integrity in radiopharmaceutical manufacturing.
Belanger AP; Byrne JF; Paolino JM; DeGrado TR
Nucl Med Biol; 2009 Nov; 36(8):955-9. PubMed ID: 19875052
[TBL] [Abstract][Full Text] [Related]
15. Air-Water Binary Gas Integrity Test for Sterilizing and Virus Filters.
Giglia S; Caulmare J; Nhiem D; Porreca D
PDA J Pharm Sci Technol; 2016 11/12; 70(6):577-590. PubMed ID: 27789800
[TBL] [Abstract][Full Text] [Related]
16. Consequences of microbial contamination during extended intravenous therapy using inline filters.
Rusmin S; Althauser MB; DeLuca PP
Am J Hosp Pharm; 1975 Apr; 32(4):373-7. PubMed ID: 805533
[TBL] [Abstract][Full Text] [Related]
17. Sterilizing filtration of liposome and related lipid-containing solutions: enhancing successful filter qualification.
Folmsbee M; Moussourakis M
PDA J Pharm Sci Technol; 2012; 66(2):161-7. PubMed ID: 22492601
[TBL] [Abstract][Full Text] [Related]
18. Benchmarking of Sterilizing-Grade Filter Membranes with Liposome Filtration.
Singh B; Mundlamuri R; Friese T; Mundrigi A; Handt S; Loewe T
PDA J Pharm Sci Technol; 2018; 72(3):223-235. PubMed ID: 29242392
[TBL] [Abstract][Full Text] [Related]
19. Absolute or sterilizing grade filtration--what is required?
Kawamura K; Jornitz MW; Meltzer TH
PDA J Pharm Sci Technol; 2000; 54(6):485-92. PubMed ID: 11107841
[No Abstract] [Full Text] [Related]
20. Influence of size, shape, and flexibility on bacterial passage through micropore membrane filters.
Wang Y; Hammes F; Düggelin M; Egli T
Environ Sci Technol; 2008 Sep; 42(17):6749-54. PubMed ID: 18800559
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]