298 related articles for article (PubMed ID: 32467463)
1. Use of bilobed partial resuscitative endovascular balloon occlusion of the aorta is logistically superior in prolonged management of a highly lethal aortic injury.
Zilberman-Rudenko J; Behrens B; McCully B; Dewey EN; Smith SG; Murphy JM; Goodman A; Underwood SJ; Rick EA; Madtson BM; Thompson ME; Glaser JJ; Holcomb JB; Schreiber MA
J Trauma Acute Care Surg; 2020 Sep; 89(3):464-473. PubMed ID: 32467463
[TBL] [Abstract][Full Text] [Related]
2. Validation of a novel partial resuscitative endovascular balloon occlusion of the aorta device in a swine hemorrhagic shock model: Fine tuning flow to optimize bleeding control and reperfusion injury.
Forte DM; Do WS; Weiss JB; Sheldon RR; Kuckelman JP; Cook BA; Levine TC; Eckert MJ; Martin MJ
J Trauma Acute Care Surg; 2020 Jul; 89(1):58-67. PubMed ID: 32569103
[TBL] [Abstract][Full Text] [Related]
3. Partial Resuscitative Endovascular Balloon Occlusion of the Aorta via the Tri-Lobe Balloon Catheter.
Daniel L; Christopher M; Dominic F; Kaitlin M; Jason B; Matthew M; Matthew E; Jason P
J Surg Res; 2021 Apr; 260():20-27. PubMed ID: 33316756
[TBL] [Abstract][Full Text] [Related]
4. A New Pressure-Regulated, Partial Resuscitative Endovascular Balloon Occlusion of the Aorta Device Achieves Targeted Distal Perfusion.
White JM; Ronaldi AE; Polcz JE; Spreadborough P; Madurska M; Mares JA; Leung LY; Rasmussen TE
J Surg Res; 2020 Dec; 256():171-179. PubMed ID: 32707400
[TBL] [Abstract][Full Text] [Related]
5. A novel partial resuscitative endovascular balloon aortic occlusion device that can be deployed in zone 1 for more than 2 hours with minimal provider titration.
Kemp MT; Wakam GK; Williams AM; Biesterveld BE; O'Connell RL; Vercruysse CA; Chtraklin K; Russo RM; Alam HB
J Trauma Acute Care Surg; 2021 Mar; 90(3):426-433. PubMed ID: 33492106
[TBL] [Abstract][Full Text] [Related]
6. Extending the golden hour for Zone 1 resuscitative endovascular balloon occlusion of the aorta: Improved survival and reperfusion injury with intermittent versus continuous resuscitative endovascular balloon occlusion of the aorta of the aorta in a porcine severe truncal hemorrhage model.
Kuckelman JP; Barron M; Moe D; Derickson M; Phillips C; Kononchik J; Lallemand M; Marko S; Eckert M; Martin MJ
J Trauma Acute Care Surg; 2018 Aug; 85(2):318-326. PubMed ID: 30080780
[TBL] [Abstract][Full Text] [Related]
7. Mitigating Ischemia-Reperfusion Injury Using a Bilobed Partial REBOA Catheter: Controlled Lower-Body Hypotension.
Necsoiu C; Jordan BS; Choi JH; Moon JJ; Espinoza MD; Gremmer BJ; Batchinsky AI; Cancio LC
Shock; 2021 Mar; 55(3):396-406. PubMed ID: 32826820
[TBL] [Abstract][Full Text] [Related]
8. Not ready for prime time: Intermittent versus partial resuscitative endovascular balloon occlusion of the aorta for prolonged hemorrhage control in a highly lethal porcine injury model.
Johnson MA; Hoareau GL; Beyer CA; Caples CA; Spruce M; Grayson JK; Neff LP; Williams TK
J Trauma Acute Care Surg; 2020 Feb; 88(2):298-304. PubMed ID: 31996655
[TBL] [Abstract][Full Text] [Related]
9. Partial Resuscitative Endovascular Balloon Occlusion of the Aorta Limits Ischemia-Reperfusion Injury After Simulated Aeromedical Evacuation.
Singer KE; Wallen TE; Youngs J; Blakeman TC; Schuster RM; Stuever MF; Goodman MD
J Surg Res; 2023 Mar; 283():118-126. PubMed ID: 36403405
[TBL] [Abstract][Full Text] [Related]
10. Titrate to equilibrate and not exsanguinate! Characterization and validation of a novel partial resuscitative endovascular balloon occlusion of the aorta catheter in normal and hemorrhagic shock conditions.
Forte DM; Do WS; Weiss JB; Sheldon RR; Kuckelman JP; Eckert MJ; Martin MJ
J Trauma Acute Care Surg; 2019 Nov; 87(5):1015-1025. PubMed ID: 31135770
[TBL] [Abstract][Full Text] [Related]
11. Next-Generation REBOA (Resuscitative Endovascular Balloon Occlusion of the Aorta) Device Precisely Achieves Targeted Regional Optimization in a Porcine Model of Hemorrhagic Shock.
Polcz JE; Ronaldi AE; Madurska M; Bedocs P; Leung LY; Burmeister DM; White PW; Rasmussen TE; White JM
J Surg Res; 2022 Dec; 280():1-9. PubMed ID: 35939866
[TBL] [Abstract][Full Text] [Related]
12. Endovascular variable aortic control (EVAC) versus resuscitative endovascular balloon occlusion of the aorta (REBOA) in a swine model of hemorrhage and ischemia reperfusion injury.
Williams TK; Tibbits EM; Hoareau GL; Simon MA; Davidson AJ; DeSoucy ES; Faulconer ER; Grayson JK; Neff LP; Johnson MA
J Trauma Acute Care Surg; 2018 Sep; 85(3):519-526. PubMed ID: 30142105
[TBL] [Abstract][Full Text] [Related]
13. A novel fluoroscopy-free, resuscitative endovascular aortic balloon occlusion system in a model of hemorrhagic shock.
Scott DJ; Eliason JL; Villamaria C; Morrison JJ; Houston R; Spencer JR; Rasmussen TE
J Trauma Acute Care Surg; 2013 Jul; 75(1):122-8. PubMed ID: 23940855
[TBL] [Abstract][Full Text] [Related]
14. The physiology of aortic flow and pressures during partial resuscitative endovascular balloon occlusion of the aorta in a swine model of hemorrhagic shock.
Marble J; Patel NTP; Lane MR; Williams TK; Neff LP; Johnson MA
J Trauma Acute Care Surg; 2022 Aug; 93(2S Suppl 1):S94-S101. PubMed ID: 35545802
[TBL] [Abstract][Full Text] [Related]
15. Prolonging the zone 1 aortic occlusion time to 4 hours using a partial resuscitative endovascular balloon in a swine model.
Ho JW; Jin G; Nguyen J; Keeney-Bonthrone TP; Diaz-Perez DA; Dawood ZS; Kemp MT; Alam JS; Gauger MA; Shaikh A; Chtraklin K; Liu B; Alam HB
J Trauma Acute Care Surg; 2023 Aug; 95(2S Suppl 1):S129-S136. PubMed ID: 37184494
[TBL] [Abstract][Full Text] [Related]
16. Partial Resuscitative Endovascular Balloon Occlusion of the Aorta in Swine Model of Hemorrhagic Shock.
Russo RM; Neff LP; Lamb CM; Cannon JW; Galante JM; Clement NF; Grayson JK; Williams TK
J Am Coll Surg; 2016 Aug; 223(2):359-68. PubMed ID: 27138649
[TBL] [Abstract][Full Text] [Related]
17. Extending resuscitative endovascular balloon occlusion of the aorta: Endovascular variable aortic control in a lethal model of hemorrhagic shock.
Williams TK; Neff LP; Johnson MA; Ferencz SA; Davidson AJ; Russo RM; Rasmussen TE
J Trauma Acute Care Surg; 2016 Aug; 81(2):294-301. PubMed ID: 27070441
[TBL] [Abstract][Full Text] [Related]
18. Transition of Resuscitative Endovascular Balloon Occlusion of the Aorta from Zone 3 to Zone 1 to Treat Hemodynamic Collapse during Continued Hemorrhage.
Rall JM; Baker KJ; Sandoval ML; Flinn AN; Causey MW
Mil Med; 2024 Jan; 189(1-2):e285-e290. PubMed ID: 37552642
[TBL] [Abstract][Full Text] [Related]
19. Partial vs Full Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) in a Swine Model of Raised Intracranial Pressure and Hemorrhagic Shock.
Edwards J; Abdou H; Stonko DP; Treffalls RN; Elansary N; Lang E; Morrison JJ
J Am Coll Surg; 2023 Jan; 236(1):241-252. PubMed ID: 36519920
[TBL] [Abstract][Full Text] [Related]
20. Resuscitative endovascular balloon occlusion of the aorta for thoracic trauma: A translational swine study.
Glaser JJ; Neidert LE; Morgan CG; Brenner M; Stigall KS; Cardin S
J Trauma Acute Care Surg; 2020 Sep; 89(3):474-481. PubMed ID: 32345903
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]