These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

247 related articles for article (PubMed ID: 32482834)

  • 1. Periprocedural to 1-year safety and efficacy outcomes with the Pipeline Embolization Device with Shield technology for intracranial aneurysms: a prospective, post-market, multi-center study.
    Rice H; Martínez Galdámez M; Holtmannspötter M; Spelle L; Lagios K; Ruggiero M; Vega P; Sonwalkar H; Chapot R; Lamin S
    J Neurointerv Surg; 2020 Nov; 12(11):1107-1112. PubMed ID: 32482834
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Treatment of intracranial aneurysms using the pipeline flex embolization device with shield technology: angiographic and safety outcomes at 1-year follow-up.
    Martínez-Galdámez M; Lamin SM; Lagios KG; Liebig T; Ciceri EF; Chapot R; Stockx L; Chavda S; Kabbasch C; Faragò G; Nordmeyer H; Boulanger T; Piano M; Boccardi EP
    J Neurointerv Surg; 2019 Apr; 11(4):396-399. PubMed ID: 30262655
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Periprocedural outcomes and early safety with the use of the Pipeline Flex Embolization Device with Shield Technology for unruptured intracranial aneurysms: preliminary results from a prospective clinical study.
    Martínez-Galdámez M; Lamin SM; Lagios KG; Liebig T; Ciceri EF; Chapot R; Stockx L; Chavda S; Kabbasch C; Farago G; Nordmeyer H; Boulanger T; Piano M; Boccardi EP
    J Neurointerv Surg; 2017 Aug; 9(8):772-776. PubMed ID: 28223428
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Prospective study on embolization of intracranial aneurysms with the pipeline device: the PREMIER study 1 year results.
    Hanel RA; Kallmes DF; Lopes DK; Nelson PK; Siddiqui A; Jabbour P; Pereira VM; Szikora István I; Zaidat OO; Bettegowda C; Colby GP; Mokin M; Schirmer C; Hellinger FR; Given Ii C; Krings T; Taussky P; Toth G; Fraser JF; Chen M; Priest R; Kan P; Fiorella D; Frei D; Aagaard-Kienitz B; Diaz O; Malek AM; Cawley CM; Puri AS
    J Neurointerv Surg; 2020 Jan; 12(1):62-66. PubMed ID: 31308197
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Safety and Effectiveness of the Pipeline Flex Embolization Device With Shield Technology for the Treatment of Intracranial Aneurysms: Midterm Results From a Multicenter Study.
    Trivelato FP; Wajnberg E; Rezende MTS; Ulhôa AC; Piske RL; Abud TG; de Castro-Afonso LH; Abath CGC; Nakiri GS; Araújo JFS; Silva JLJ; Tosello RT; Vanzin JR; Manzato LB; Baccin CE; da Mota BAA; Abud DG
    Neurosurgery; 2020 Jul; 87(1):104-111. PubMed ID: 31504821
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Diffusion weighted image documented cerebral ischemia in the postprocedural period following pipeline embolization device with shield technology treatment of unruptured intracranial aneurysms: a prospective, single center study.
    Pikis S; Mantziaris G; Mamalis V; Barkas K; Tsanis A; Lyra S; Karkoulias K; Petrosyan T; Archontakis E
    J Neurointerv Surg; 2020 Apr; 12(4):407-411. PubMed ID: 31558655
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of PED/PED Flex and PED Shield in the treatment of unruptured intracerebral aneurysms.
    El Naamani K; Mastorakos P; Yudkoff CJ; Abbas R; Tjoumakaris SI; Gooch MR; Herial NA; Rosenwasser RH; Zarzour H; Schmidt RF; Jabbour PM
    J Neurosurg; 2024 Feb; 140(2):436-440. PubMed ID: 37877979
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Neuroform Atlas Stent System for the treatment of intracranial aneurysm: primary results of the Atlas Humanitarian Device Exemption cohort.
    Jankowitz BT; Hanel R; Jadhav AP; Loy DN; Frei D; Siddiqui AH; Puri AS; Khaldi A; Turk AS; Malek AM; Sauvageau E; Hetts SW; Zaidat OO
    J Neurointerv Surg; 2019 Aug; 11(8):801-806. PubMed ID: 30670625
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Multiple pipeline embolization devices improves aneurysm occlusion without increasing morbidity: A single center experience of 140 cases.
    Link TW; Carnevale JA; Goldberg JL; Jones C; Kocharian G; Boddu SR; Lin N; Patsalides A; Gobin YP; Knopman J
    J Clin Neurosci; 2021 Apr; 86():129-135. PubMed ID: 33775316
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pipeline shield with single antiplatelet therapy in aneurysmal subarachnoid haemorrhage: multicentre experience.
    Manning NW; Cheung A; Phillips TJ; Wenderoth JD
    J Neurointerv Surg; 2019 Jul; 11(7):694-698. PubMed ID: 30552166
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Pipeline Embolization Device for Intracranial Aneurysms in a Large Chinese Cohort: Complication Risk Factor Analysis.
    Kang H; Zhou Y; Luo B; Lv N; Zhang H; Li T; Song D; Zhao Y; Guan S; Maimaitili A; Wang Y; Feng W; Wang Y; Wan J; Mao G; Shi H; Yang X; Liu J
    Neurotherapeutics; 2021 Apr; 18(2):1198-1206. PubMed ID: 33447904
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Morbidity and Mortality in Patients With Posterior Circulation Aneurysms Treated With the Pipeline Embolization Device: A Subgroup Analysis of the International Retrospective Study of the Pipeline Embolization Device.
    Lopes DK; Jang DK; Cekirge S; Fiorella D; Hanel RA; Kallmes DF; Levy EI; Lylyk P
    Neurosurgery; 2018 Sep; 83(3):488-500. PubMed ID: 28945879
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Early postmarket results after treatment of intracranial aneurysms with the pipeline embolization device: a U.S. multicenter experience.
    Kan P; Siddiqui AH; Veznedaroglu E; Liebman KM; Binning MJ; Dumont TM; Ogilvy CS; Gaughen JR; Mocco J; Velat GJ; Ringer AJ; Welch BG; Horowitz MB; Snyder KV; Hopkins LN; Levy EI
    Neurosurgery; 2012 Dec; 71(6):1080-7; discussion 1087-8. PubMed ID: 22948199
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pipeline-assisted coiling versus pipeline in flow diversion treatment of intracranial aneurysms.
    Sweid A; Atallah E; Herial N; Saad H; Mouchtouris N; Barros G; Gooch MR; Tjoumakaris S; Zarzour H; Hasan D; Chalouhi N; Rosenwasser RH; Jabbour P
    J Clin Neurosci; 2018 Dec; 58():20-24. PubMed ID: 30454690
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Safety and efficacy of the Pipeline embolization device for treatment of intracranial aneurysms: a pooled analysis of 3 large studies.
    Kallmes DF; Brinjikji W; Cekirge S; Fiorella D; Hanel RA; Jabbour P; Lopes D; Lylyk P; McDougall CG; Siddiqui A
    J Neurosurg; 2017 Oct; 127(4):775-780. PubMed ID: 27791519
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Age-related outcomes following intracranial aneurysm treatment with the Pipeline Embolization Device: a subgroup analysis of the IntrePED registry.
    Brinjikji W; Kallmes DF; Cloft HJ; Lanzino G
    J Neurosurg; 2016 Jun; 124(6):1726-30. PubMed ID: 26544776
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Prospective study on embolization of intracranial aneurysms with the pipeline device (PREMIER study): 3-year results with the application of a flow diverter specific occlusion classification.
    Hanel RA; Cortez GM; Lopes DK; Nelson PK; Siddiqui AH; Jabbour P; Mendes Pereira V; István IS; Zaidat OO; Bettegowda C; Colby GP; Mokin M; Schirmer CM; Hellinger FR; Given C; Krings T; Taussky P; Toth G; Fraser JF; Chen M; Priest R; Kan P; Fiorella D; Frei D; Aagaard-Kienitz B; Diaz O; Malek AM; Cawley CM; Puri AS; Kallmes DF
    J Neurointerv Surg; 2023 Mar; 15(3):248-254. PubMed ID: 35292570
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pivotal Trial of the Neuroform Atlas Stent for Treatment of Anterior Circulation Aneurysms: One-Year Outcomes.
    Zaidat OO; Hanel RA; Sauvageau EA; Aghaebrahim A; Lin E; Jadhav AP; Jovin TG; Khaldi A; Gupta RG; Johnson A; Frei D; Loy D; Malek A; Toth G; Siddiqui A; Reavey-Cantwell J; Thomas A; Hetts SW; Jankowitz BT;
    Stroke; 2020 Jul; 51(7):2087-2094. PubMed ID: 32568654
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pipeline Flex embolisation device with Shield Technology for the treatment of patients with intracranial aneurysms: periprocedural and 6 month outcomes.
    Yeomans J; Sandu L; Sastry A
    Neuroradiol J; 2020 Dec; 33(6):471-478. PubMed ID: 33092461
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pipeline Embolization Devices for the Treatment of Intracranial Aneurysms, Single-Center Registry: Long-Term Angiographic and Clinical Outcomes from 1000 Aneurysms.
    Lylyk I; Scrivano E; Lundquist J; Ferrario A; Bleise C; Perez N; Lylyk PN; Viso R; Nella-Castro R; Lylyk P
    Neurosurgery; 2021 Aug; 89(3):443-449. PubMed ID: 34098575
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.