BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

407 related articles for article (PubMed ID: 32497567)

  • 1. Coronary angiography and percutaneous coronary intervention after transcatheter aortic valve replacement with medtronic self-expanding prosthesis: Insights from correlations with computer tomography.
    Khan M; Senguttuvan NB; Krishnamoorthy P; Vengrenyuk Y; Tang GHL; Sharma SK; Kini A
    Int J Cardiol; 2020 Oct; 317():18-24. PubMed ID: 32497567
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Incidence, Technical Safety, and Feasibility of Coronary Angiography and Intervention Following Self-expanding Transcatheter Aortic Valve Replacement.
    Tanaka A; Jabbour RJ; Testa L; Agnifili M; Ettori F; Fiorina C; Adamo M; Bruschi G; Giannini C; Petronio AS; Barbanti M; Tamburino C; De Felice F; Reimers B; Poli A; Colombo A; Latib A
    Cardiovasc Revasc Med; 2019 May; 20(5):371-375. PubMed ID: 30857975
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Feasibility of coronary angiography and percutaneous coronary intervention after transcatheter aortic valve replacement using a Medtronic™ self-expandable bioprosthetic valve.
    Htun WW; Grines C; Schreiber T
    Catheter Cardiovasc Interv; 2018 Jun; 91(7):1339-1344. PubMed ID: 28988450
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Coronary Access After TAVR.
    Ochiai T; Chakravarty T; Yoon SH; Kaewkes D; Flint N; Patel V; Mahani S; Tiwana R; Sekhon N; Nakamura M; Cheng W; Makkar R
    JACC Cardiovasc Interv; 2020 Mar; 13(6):693-705. PubMed ID: 32192689
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Coronary angiography and percutaneous coronary intervention after transcatheter aortic valve replacement: Feasibility in clinical practice.
    Silva G; Silva M; Guerreiro C; Sampaio F; Pires-Morais G; Santos L; Melica B; Rodrigues A; Braga P; Fontes-Carvalho R
    Rev Port Cardiol; 2023 Sep; 42(9):749-756. PubMed ID: 36958581
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A systematic review and meta-analysis of delayed coronary artery access for coronary angiography with or without percutaneous coronary intervention (PCI) in patients who underwent transcatheter aortic valve replacement (TAVR).
    Diaz MA; Patton M; Valdes P; Vieira JL; Rmeileh A; Macedo FY
    Cardiovasc Interv Ther; 2022 Jan; 37(1):167-181. PubMed ID: 33453034
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Complexity assessment and technical aspect of coronary angiogram and percutaneous coronary intervention following transcatheter aortic valve implantation.
    Perrin N; Fassa A; Baroz A; Frangos C; Mock S; Frei A; Cimci M; Degrauwe S; Roffi M; Iglesias JF; Noble S
    Cardiol J; 2022; 29(2):197-204. PubMed ID: 32436588
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Feasibility of Coronary Access and Aortic Valve Reintervention in Low-Risk TAVR Patients.
    Rogers T; Greenspun BC; Weissman G; Torguson R; Craig P; Shults C; Gordon P; Ehsan A; Wilson SR; Goncalves J; Levitt R; Hahn C; Parikh P; Bilfinger T; Butzel D; Buchanan S; Hanna N; Garrett R; Buchbinder M; Asch F; Garcia-Garcia HM; Okubagzi P; Ben-Dor I; Satler LF; Waksman R
    JACC Cardiovasc Interv; 2020 Mar; 13(6):726-735. PubMed ID: 32192693
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Coronary Access After TAVR With a Self-Expanding Bioprosthesis: Insights From Computed Tomography.
    Abdelghani M; Landt M; Traboulsi H; Becker B; Richardt G
    JACC Cardiovasc Interv; 2020 Mar; 13(6):709-722. PubMed ID: 32192691
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Incidence and feasibility of coronary access after transcatheter aortic valve replacement.
    Nai Fovino L; Scotti A; Massussi M; Fabris T; Cardaioli F; Rodinò G; Matsuda Y; Frigo F; Fraccaro C; Tarantini G
    Catheter Cardiovasc Interv; 2020 Nov; 96(5):E535-E541. PubMed ID: 31912968
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Coronary Cannulation Following TAVR Using Self-Expanding Devices With Commissural Alignment: The RE-ACCESS 2 Study.
    Costa G; Sammartino S; Strazzieri O; Motta S; Frittitta V; Dipietro E; Comis A; Calì M; Garretto V; Inserra C; Cannizzaro MT; Sgroi C; Tamburino C; Barbanti M
    JACC Cardiovasc Interv; 2024 Mar; 17(6):727-737. PubMed ID: 38456879
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Incidence, feasibility and outcome of percutaneous coronary intervention after transcatheter aortic valve implantation with a self-expanding prosthesis. Results from a single center experience.
    Allali A; El-Mawardy M; Schwarz B; Sato T; Geist V; Toelg R; Richardt G; Abdel-Wahab M
    Cardiovasc Revasc Med; 2016 Sep; 17(6):391-8. PubMed ID: 27396607
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Alignment of Transcatheter Aortic-Valve Neo-Commissures (ALIGN TAVR): Impact on Final Valve Orientation and Coronary Artery Overlap.
    Tang GHL; Zaid S; Fuchs A; Yamabe T; Yazdchi F; Gupta E; Ahmad H; Kofoed KF; Goldberg JB; Undemir C; Kaple RK; Shah PB; Kaneko T; Lansman SL; Khera S; Kovacic JC; Dangas GD; Lerakis S; Sharma SK; Kini A; Adams DH; Khalique OK; Hahn RT; Søndergaard L; George I; Kodali SK; De Backer O; Leon MB; Bapat VN
    JACC Cardiovasc Interv; 2020 May; 13(9):1030-1042. PubMed ID: 32192985
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Safety and Efficacy of Self-Expanding TAVR in Patients With Aortoventricular Angulation.
    Popma JJ; Reardon MJ; Yakubov SJ; Hermiller JB; Harrison JK; Gleason TG; Conte JV; Deeb GM; Chetcuti S; Oh JK; Boulware MJ; Huang J; Adams DH;
    JACC Cardiovasc Imaging; 2016 Aug; 9(8):973-81. PubMed ID: 27491485
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Coronary Angiography After Transcatheter Aortic Valve Replacement (TAVR) to Evaluate the Risk of Coronary Access Impairment After TAVR-in-TAVR.
    Nai Fovino L; Scotti A; Massussi M; Cardaioli F; Rodinò G; Matsuda Y; Pavei A; Masiero G; Napodano M; Fraccaro C; Fabris T; Tarantini G
    J Am Heart Assoc; 2020 Jul; 9(13):e016446. PubMed ID: 32578484
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Coronary Access After Transcatheter Aortic Valve Replacement With Commissural Alignment: The ALIGN-ACCESS Study.
    Tarantini G; Nai Fovino L; Scotti A; Massussi M; Cardaioli F; Rodinò G; Benedetti A; Boiago M; Matsuda Y; Continisio S; Montonati C; Cacciavillani L; Pavei A; Masiero G; Napodano M; Fraccaro C; Fabris T; Iliceto S
    Circ Cardiovasc Interv; 2022 Feb; 15(2):e011045. PubMed ID: 35167332
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Technical Characteristics and Feasibility of Coronary Angiography and Percutaneous Coronary Interventions Performed after Transcatheter Aortic Valve Replacement with Self-Expanding Valves.
    Tsai CT; Chang HH; Leu HB; Ling K; Chen IM; Chen PL; Lin SM; Chen YH
    Acta Cardiol Sin; 2022 Jan; 38(1):56-63. PubMed ID: 35068884
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Feasibility of Coronary Access in Patients With Acute Coronary Syndrome and Previous TAVR.
    Kim WK; Pellegrini C; Ludwig S; Möllmann H; Leuschner F; Makkar R; Leick J; Amat-Santos IJ; Dörr O; Breitbart P; Jimenez Diaz VA; Dabrowski M; Rudolph T; Avanzas P; Kaur J; Toggweiler S; Kerber S; Ranosch P; Regazzoli D; Frank D; Landes U; Webb J; Barbanti M; Purita P; Pilgrim T; Liska B; Tabata N; Rheude T; Seiffert M; Eckel C; Allali A; Valvo R; Yoon SH; Werner N; Nef H; Choi YH; Hamm CW; Sinning JM
    JACC Cardiovasc Interv; 2021 Jul; 14(14):1578-1590. PubMed ID: 34294400
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Outcomes in Patients With Transcatheter Aortic Valve Replacement and Left Main Stenting: The TAVR-LM Registry.
    Chakravarty T; Sharma R; Abramowitz Y; Kapadia S; Latib A; Jilaihawi H; Poddar KL; Giustino G; Ribeiro HB; Tchetche D; Monteil B; Testa L; Tarantini G; Facchin M; Lefèvre T; Lindman BR; Hariri B; Patel J; Takahashi N; Matar G; Mirocha J; Cheng W; Tuzcu ME; Sievert H; Rodés-Cabau J; Colombo A; Finkelstein A; Fajadet J; Makkar RR
    J Am Coll Cardiol; 2016 Mar; 67(8):951-960. PubMed ID: 26916485
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Risk of Coronary Obstruction and Feasibility of Coronary Access After Repeat Transcatheter Aortic Valve Replacement With the Self-Expanding Evolut Valve: A Computed Tomography Simulation Study.
    Forrestal BJ; Case BC; Yerasi C; Shea C; Torguson R; Zhang C; Ben-Dor I; Deksissa T; Ali S; Satler LF; Shults C; Weissman G; Wang JC; Khan JM; Waksman R; Rogers T
    Circ Cardiovasc Interv; 2020 Dec; 13(12):e009496. PubMed ID: 33272031
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 21.