These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

177 related articles for article (PubMed ID: 32498062)

  • 1. Preclinical evaluation of a mini-arthroplasty implant based on polyetheretherketone and Ti6AI4V for treatment of a focal osteochondral defect in the femoral head of the hip.
    Zhang W; Yuan Z; Meng X; Zhang J; Long T; Yaochao Z; Yang C; Lin R; Yue B; Guo Q; Wang Y
    Biomed Mater; 2020 Aug; 15(5):055027. PubMed ID: 32498062
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A partial hemi-resurfacing preliminary study of a novel magnetic resonance imaging compatible polyetheretherketone mini-prosthesis for focal osteochondral defects.
    Meng X; Zhang W; Yuan Z; Chen J; Lyu Z; Wang Y
    J Orthop Translat; 2021 Jan; 26():67-73. PubMed ID: 33437625
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Biological and functional evaluation of a novel pyrolytic carbon implant for the treatment of focal osteochondral defects in the medial femoral condyle: assessment in a canine model.
    Salkeld SL; Patron LP; Lien JC; Cook SD; Jones DG
    J Orthop Surg Res; 2016 Dec; 11(1):155. PubMed ID: 27906096
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Articular cartilage degeneration following the treatment of focal cartilage defects with ceramic metal implants and compared with microfracture.
    Custers RJ; Saris DB; Dhert WJ; Verbout AJ; van Rijen MH; Mastbergen SC; Lafeber FP; Creemers LB
    J Bone Joint Surg Am; 2009 Apr; 91(4):900-10. PubMed ID: 19339575
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An investigational time course study of titanium plasma spray on osseointegration of PEEK and titanium implants: an in vivo ovine model.
    Cunningham BW; Brooks DM; Rolle NP; Weiner DA; Wang W
    Spine J; 2024 Apr; 24(4):721-729. PubMed ID: 37875243
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The degree of peri-implant osteolysis induced by PEEK, CoCrMo, and HXLPE wear particles: a study based on a porous Ti6Al4V implant in a rabbit model.
    Du Z; Zhu Z; Wang Y
    J Orthop Surg Res; 2018 Jan; 13(1):23. PubMed ID: 29386035
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The in vivo response to a novel Ti coating compared with polyether ether ketone: evaluation of the periphery and inner surfaces of an implant.
    Walsh WR; Pelletier MH; Christou C; He J; Vizesi F; Boden SD
    Spine J; 2018 Jul; 18(7):1231-1240. PubMed ID: 29496625
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cartilage degeneration in the goat knee caused by treating localized cartilage defects with metal implants.
    Custers RJ; Dhert WJ; Saris DB; Verbout AJ; van Rijen MH; Mastbergen SC; Lafeber FP; Creemers LB
    Osteoarthritis Cartilage; 2010 Mar; 18(3):377-88. PubMed ID: 19880000
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [
    Wang LX; Xu X; Ni YF; Sun HT; Yu RY; Wei SC
    Beijing Da Xue Xue Bao Yi Xue Ban; 2021 Aug; 53(4):758-763. PubMed ID: 34393241
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Stress and strain distribution in femoral heads for hip resurfacing arthroplasty with different materials: A finite element analysis.
    Vogel D; Wehmeyer M; Kebbach M; Heyer H; Bader R
    J Mech Behav Biomed Mater; 2021 Jan; 113():104115. PubMed ID: 33189013
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of osteointegration property between PEKK and PEEK: Effects of surface structure and chemistry.
    Yuan B; Cheng Q; Zhao R; Zhu X; Yang X; Yang X; Zhang K; Song Y; Zhang X
    Biomaterials; 2018 Jul; 170():116-126. PubMed ID: 29660634
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of 3D-printed titanium-alloy, standard titanium-alloy, and PEEK interbody spacers in an ovine model.
    Van Horn MR; Beard R; Wang W; Cunningham BW; Mullinix KP; Allall M; Bucklen BS
    Spine J; 2021 Dec; 21(12):2097-2103. PubMed ID: 34029756
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Porous PEEK improves the bone-implant interface compared to plasma-sprayed titanium coating on PEEK.
    Torstrick FB; Lin ASP; Potter D; Safranski DL; Sulchek TA; Gall K; Guldberg RE
    Biomaterials; 2018 Dec; 185():106-116. PubMed ID: 30236838
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In Vivo Osseointegration Performance of Titanium Dioxide Coating Modified Polyetheretherketone Using Arc Ion Plating for Spinal Implant Application.
    Tsou HK; Chi MH; Hung YW; Chung CJ; He JL
    Biomed Res Int; 2015; 2015():328943. PubMed ID: 26504800
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Five million wear simulation and particle analysis of carbon-based nano-multilayer coatings titanium alloy femoral head].
    Wang HR; Li J; Li ZL; Tu JP; Jin G; Su J; Wang JJ
    Zhonghua Yi Xue Za Zhi; 2020 Feb; 100(7):546-551. PubMed ID: 32164109
    [No Abstract]   [Full Text] [Related]  

  • 16. Orthopedic implant cobalt-alloy particles produce greater toxicity and inflammatory cytokines than titanium alloy and zirconium alloy-based particles in vitro, in human osteoblasts, fibroblasts, and macrophages.
    Dalal A; Pawar V; McAllister K; Weaver C; Hallab NJ
    J Biomed Mater Res A; 2012 Aug; 100(8):2147-58. PubMed ID: 22615169
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of Surface Topography and Chemistry on Polyether-Ether-Ketone (PEEK) and Titanium Osseointegration.
    Torstrick FB; Lin ASP; Safranski DL; Potter D; Sulchek T; Lee CSD; Gall K; Guldberg RE
    Spine (Phila Pa 1976); 2020 Apr; 45(8):E417-E424. PubMed ID: 31703050
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Biomechanical implant fixation of CoCrMo coating inferior to titanium coating in a canine implant model.
    Jakobsen SS; Baas J; Jakobsen T; Soballe K
    J Biomed Mater Res A; 2010 Jul; 94(1):180-6. PubMed ID: 20128008
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Do Surface Porosity and Pore Size Influence Mechanical Properties and Cellular Response to PEEK?
    Torstrick FB; Evans NT; Stevens HY; Gall K; Guldberg RE
    Clin Orthop Relat Res; 2016 Nov; 474(11):2373-2383. PubMed ID: 27154533
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Nutrient Element Decorated Polyetheretherketone Implants Steer Mitochondrial Dynamics for Boosted Diabetic Osseointegration.
    Wang H; Fu X; Shi J; Li L; Sun J; Zhang X; Han Q; Deng Y; Gan X
    Adv Sci (Weinh); 2021 Oct; 8(20):e2101778. PubMed ID: 34396715
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.