These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

402 related articles for article (PubMed ID: 32499069)

  • 41. Minimally invasive screw fixation is as stable as anterior plating in acetabular T-Type fractures - a biomechanical study.
    Becker CA; Kammerlander C; Cavalcanti Kußmaul A; Dotzauer F; Woiczinski M; Rubenbauer B; Sommer F; Linhart C; Weidert S; Zeckey C; Greiner A
    Orthop Traumatol Surg Res; 2018 Nov; 104(7):1055-1061. PubMed ID: 30179721
    [TBL] [Abstract][Full Text] [Related]  

  • 42. A biomechanical comparison of double-plate and Y-plate fixation for comminuted equine second phalangeal fractures.
    Galuppo LD; Stover SM; Willits NH
    Vet Surg; 2000; 29(2):152-62. PubMed ID: 10730708
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Calcar screw position in proximal humerus fracture fixation: Don't miss high!
    Mehta S; Chin M; Sanville J; Namdari S; Hast MW
    Injury; 2018 Mar; 49(3):624-629. PubMed ID: 29452734
    [TBL] [Abstract][Full Text] [Related]  

  • 44. [MODIFIED INTRAMEDULLARY FIXATION WITH TWO Kirschner WIRES FOR EXTRA-ARTICULAR FRACTURE OF PROXIMAL PHALANGEAL BASE].
    Li S; Wu K; Xie L; Chen L
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2016 Aug; 30(8):935-938. PubMed ID: 29786219
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Treatment of distal intraarticular tibial fractures: A biomechanical evaluation of intramedullary nailing vs. angle-stable plate osteosynthesis.
    Kuhn S; Greenfield J; Arand C; Jarmolaew A; Appelmann P; Mehler D; Rommens PM
    Injury; 2015 Oct; 46 Suppl 4():S99-S103. PubMed ID: 26542874
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Biomechanical Comparison Study of Three Fixation Methods for Proximal Chevron Osteotomy of the First Metatarsal in Hallux Valgus.
    Kim JS; Cho HK; Young KW; Kim JS; Lee KT
    Clin Orthop Surg; 2017 Dec; 9(4):514-520. PubMed ID: 29201305
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Biomechanical stability of intramedullary technique for fixation of joint depressed calcaneus fracture.
    Nelson JD; McIff TE; Moodie PG; Iverson JL; Horton GA
    Foot Ankle Int; 2010 Mar; 31(3):229-35. PubMed ID: 20230701
    [TBL] [Abstract][Full Text] [Related]  

  • 48. A biomechanical comparison of fixed angle locking compression plate osteosynthesis and cement augmented screw osteosynthesis in the management of intra articular calcaneal fractures.
    Rausch S; Klos K; Wolf U; Gras M; Simons P; Brodt S; Windolf M; Gueorguiev B
    Int Orthop; 2014 Aug; 38(8):1705-10. PubMed ID: 24764050
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Comparison of Lag Versus Nonlag Screw Fixation for Long Oblique Proximal Phalanx Fractures: A Biomechanical Study.
    Miles MR; Green T; Parks BG; Thakkar MY; Segalman KA; Means KR
    J Hand Surg Am; 2022 May; 47(5):476.e1-476.e6. PubMed ID: 34247847
    [TBL] [Abstract][Full Text] [Related]  

  • 50. A biomechanical study of headless compression screws versus a locking plate in radial head fracture fixation.
    Rebgetz PR; Daniele L; Underhill ID; Öchsner A; Taylor FJ
    J Shoulder Elbow Surg; 2019 Apr; 28(4):e111-e116. PubMed ID: 30685273
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Cyclic loading of olecranon fracture fixation constructs.
    Hutchinson DT; Horwitz DS; Ha G; Thomas CW; Bachus KN
    J Bone Joint Surg Am; 2003 May; 85(5):831-7. PubMed ID: 12728033
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Biomechanical study of Proximal humeral fracture fixation: Locking plate with medial support screw vs. locking plate with intramedullary fibular graft.
    Jang Y; Kim D
    Clin Biomech (Bristol, Avon); 2021 Dec; 90():105510. PubMed ID: 34673363
    [TBL] [Abstract][Full Text] [Related]  

  • 53. [Results after osteosynthesis of extraarticular proximal phalangeal fractures].
    Egloff C; Sproedt J; Jandali AR
    Handchir Mikrochir Plast Chir; 2012 Jan; 44(1):5-10. PubMed ID: 22382904
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Transverse patella fracture fixation: A cadaveric biomechanical comparison of cannulated screws and anterior tension band versus low-profile, multiplanar mesh plating.
    Garner MR; Homcha B; Cowman T; Goss M; Reid JS; Lewis GS
    Injury; 2024 Jun; 55(6):111574. PubMed ID: 38669892
    [TBL] [Abstract][Full Text] [Related]  

  • 55. [Translated article] Comparison of three different minimally invasive intramedullary screw for proximal phalanx fractures. A biomechanical study.
    Gallardo-Calero I; Sevil-Mayayo R; Lluch-Bergada A; Vidal-Tarrasón N; Rodríguez-Baeza A; Esteban-Feliu I
    Rev Esp Cir Ortop Traumatol; 2023; 67(1):T50-T55. PubMed ID: 36243394
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Comparison of three different minimally invasive intramedullary screw for proximal phalanx fractures. A biomechanical study.
    Gallardo-Calero I; Sevil-Mayayo R; Lluch-Bergada A; Vidal-Tarrasón N; Rodríguez-Baeza A; Esteban-Feliu I
    Rev Esp Cir Ortop Traumatol; 2023; 67(1):50-55. PubMed ID: 35709951
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Biomechanical Analysis of the Proximal Femoral Locking Compression Plate: Do Quality of Reduction and Screw Orientation Influence Construct Stability?
    Zderic I; Oh JK; Stoffel K; Sommer C; Helfen T; Camino G; Richards G; Nork SE; Gueorguiev B
    J Orthop Trauma; 2018 Feb; 32(2):67-74. PubMed ID: 28834823
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Biomechanical cadaver testing of a fixed-angle plate in comparison to tension wiring and screw fixation in transverse patella fractures.
    Thelen S; Schneppendahl J; Jopen E; Eichler C; Koebke J; Schönau E; Hakimi M; Windolf J; Wild M
    Injury; 2012 Aug; 43(8):1290-5. PubMed ID: 22608600
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Unicortical and bicortical plating in the fixation of comminuted fractures of the clavicle: a biomechanical study.
    Looft JM; Corrêa L; Patel M; Rawlings M; Ackland DC
    ANZ J Surg; 2017 Nov; 87(11):915-920. PubMed ID: 28922701
    [TBL] [Abstract][Full Text] [Related]  

  • 60. The stability of internal fixation in the proximal phalanx.
    Black DM; Mann RJ; Constine RM; Daniels AU
    J Hand Surg Am; 1986 Sep; 11(5):672-7. PubMed ID: 3760493
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 21.