BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

340 related articles for article (PubMed ID: 32505593)

  • 1. High-pitch dual-source CT for coronary artery calcium scoring: A head-to-head comparison of non-triggered chest versus triggered cardiac acquisition.
    Xia C; Vonder M; Pelgrim GJ; Rook M; Xie X; Alsurayhi A; van Ooijen PMA; van Bolhuis JN; Oudkerk M; Dorrius M; van der Harst P; Vliegenthart R
    J Cardiovasc Comput Tomogr; 2021; 15(1):65-72. PubMed ID: 32505593
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Estimation of cardiovascular risk on routine chest CT: Ordinal coronary artery calcium scoring as an accurate predictor of Agatston score ranges.
    Azour L; Kadoch MA; Ward TJ; Eber CD; Jacobi AH
    J Cardiovasc Comput Tomogr; 2017; 11(1):8-15. PubMed ID: 27743881
    [TBL] [Abstract][Full Text] [Related]  

  • 3. High-pitch versus sequential mode for coronary calcium in individuals with a high heart rate: Potential for dose reduction.
    Vonder M; Vliegenthart R; Kaatee MA; van der Aalst CM; van Ooijen PMA; de Bock GH; Gratama JW; Kuijpers D; de Koning HJ; Oudkerk M
    J Cardiovasc Comput Tomogr; 2018; 12(4):298-304. PubMed ID: 29551663
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Coronary calcium screening with dual-source CT: reliability of ungated, high-pitch chest CT in comparison with dedicated calcium-scoring CT.
    Hutt A; Duhamel A; Deken V; Faivre JB; Molinari F; Remy J; Remy-Jardin M
    Eur Radiol; 2016 Jun; 26(6):1521-8. PubMed ID: 26340814
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Reliability analysis of visual ranking of coronary artery calcification on low-dose CT of the thorax for lung cancer screening: comparison with ECG-gated calcium scoring CT.
    Kim YK; Sung YM; Cho SH; Park YN; Choi HY
    Int J Cardiovasc Imaging; 2014 Dec; 30 Suppl 2():81-7. PubMed ID: 25084979
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Iterative beam-hardening correction with advanced modeled iterative reconstruction in low voltage CT coronary calcium scoring with tin filtration: Impact on coronary artery calcium quantification and image quality.
    Tesche C; De Cecco CN; Schoepf UJ; Duguay TM; Albrecht MH; Caruso D; Varga-Szemes A; Lesslie VW; Ebersberger U; Canstein C; Thilo C; Hoffmann E; Allmendinger T; Nance JW
    J Cardiovasc Comput Tomogr; 2017; 11(5):354-359. PubMed ID: 28756086
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Coronary artery calcium quantification on first, second and third generation dual source CT: A comparison study.
    Vonder M; Pelgrim GJ; Huijsse SEM; Haubenreisser H; Meyer M; van Ooijen PMA; Oudkerk M; Henzler T; Vliegenthart R
    J Cardiovasc Comput Tomogr; 2017 Nov; 11(6):444-448. PubMed ID: 28943454
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Relationship of Coronary Calcium on Standard Chest CT Scans With Mortality.
    Hughes-Austin JM; Dominguez A; Allison MA; Wassel CL; Rifkin DE; Morgan CG; Daniels MR; Ikram U; Knox JB; Wright CM; Criqui MH; Ix JH
    JACC Cardiovasc Imaging; 2016 Feb; 9(2):152-9. PubMed ID: 26777213
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of Clinical Applicability of Coronary Artery Calcium Assessment on Non-Gated Chest Computed Tomography, Compared With the Classic Agatston Score on Cardiac Computed Tomography.
    Groen RA; Jukema JW; van Dijkman PRM; Timmermans PT; Bax JJ; Lamb HJ; de Graaf MA
    Am J Cardiol; 2023 Dec; 208():92-100. PubMed ID: 37820552
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Prospective evaluation of the influence of iterative reconstruction on the reproducibility of coronary calcium quantification in reduced radiation dose 320 detector row CT.
    Choi AD; Leifer ES; Yu J; Shanbhag SM; Bronson K; Arai AE; Chen MY
    J Cardiovasc Comput Tomogr; 2016; 10(5):359-63. PubMed ID: 27591767
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Coronary artery calcium scoring with photon-counting CT: first in vivo human experience.
    Symons R; Sandfort V; Mallek M; Ulzheimer S; Pourmorteza A
    Int J Cardiovasc Imaging; 2019 Apr; 35(4):733-739. PubMed ID: 30635819
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Coronary artery calcium scoring assessment in ultra-low-dose chest computed tomography.
    Xiao H; Wang X; Yang P; Wang L; Xu J
    Clin Imaging; 2024 Feb; 106():110045. PubMed ID: 38056107
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of Nongated Chest CT and Dedicated Calcium Scoring CT for Coronary Calcium Quantification Using a 256-Dector Row CT Scanner.
    Chen Y; Hu Z; Li M; Jia Y; He T; Liu Z; Wei D; Yu Y
    Acad Radiol; 2019 Oct; 26(10):e267-e274. PubMed ID: 30685312
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Automated total and vessel-specific coronary artery calcium (CAC) quantification on chest CT: direct comparison with CAC scoring on non-contrast cardiac CT.
    Yu J; Qian L; Sun W; Nie Z; Zheng D; Han P; Shi H; Zheng C; Yang F
    BMC Med Imaging; 2022 Oct; 22(1):177. PubMed ID: 36241978
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The effect of iterative model reconstruction on coronary artery calcium quantification.
    Szilveszter B; Elzomor H; Károlyi M; Kolossváry M; Raaijmakers R; Benke K; Celeng C; Bartykowszki A; Bagyura Z; Lux Á; Merkely B; Maurovich-Horvat P
    Int J Cardiovasc Imaging; 2016 Jan; 32(1):153-60. PubMed ID: 26285899
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Prognostic value of visually detected coronary artery calcification on unenhanced non-gated thoracic computed tomography for prediction of non-fatal myocardial infarction and all-cause mortality.
    Shao L; Yan AT; Lebovic G; Wong HH; Kirpalani A; Deva DP
    J Cardiovasc Comput Tomogr; 2017; 11(3):196-202. PubMed ID: 28411031
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Prospectively ECG-triggered high-pitch coronary angiography with third-generation dual-source CT at 70 kVp tube voltage: feasibility, image quality, radiation dose, and effect of iterative reconstruction.
    Hell MM; Bittner D; Schuhbaeck A; Muschiol G; Brand M; Lell M; Uder M; Achenbach S; Marwan M
    J Cardiovasc Comput Tomogr; 2014; 8(6):418-25. PubMed ID: 25439789
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Differences in the association of total versus local coronary artery calcium with acute coronary syndrome and culprit lesions in patients with acute chest pain: The coronary calcium paradox.
    Puchner SB; Mayrhofer T; Park J; Lu MT; Liu T; Maurovich-Horvat P; Ghemigian K; Bittner DO; Fleg JL; Udelson JE; Truong QA; Hoffmann U; Ferencik M
    Atherosclerosis; 2018 Jul; 274():251-257. PubMed ID: 29703635
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Coronary artery calcium quantification from contrast enhanced CT using gemstone spectral imaging and material decomposition.
    Fuchs TA; Stehli J; Dougoud S; Sah BR; Bull S; Clerc OF; Possner M; Buechel RR; Gaemperli O; Kaufmann PA
    Int J Cardiovasc Imaging; 2014 Oct; 30(7):1399-405. PubMed ID: 24993390
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The impact of dose reduction on the quantification of coronary artery calcifications and risk categorization: A systematic review.
    Vonder M; van der Werf NR; Leiner T; Greuter MJW; Fleischmann D; Vliegenthart R; Oudkerk M; Willemink MJ
    J Cardiovasc Comput Tomogr; 2018; 12(5):352-363. PubMed ID: 29960743
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.