These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

219 related articles for article (PubMed ID: 32514843)

  • 1. The all-inside all-suture technique demonstrated better biomechanical behaviors in meniscus radial tear repair.
    Doig T; Fagan P; Frush T; Lovse L; Chen C; Lemos S
    Knee Surg Sports Traumatol Arthrosc; 2020 Nov; 28(11):3606-3612. PubMed ID: 32514843
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical comparison of arthroscopic repair constructs for radial tears of the meniscus.
    Branch EA; Milchteim C; Aspey BS; Liu W; Saliman JD; Anz AW
    Am J Sports Med; 2015 Sep; 43(9):2270-6. PubMed ID: 26245325
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A Novel Repair Method for Radial Tears of the Medial Meniscus: Biomechanical Comparison of Transtibial 2-Tunnel and Double Horizontal Mattress Suture Techniques Under Cyclic Loading.
    Bhatia S; Civitarese DM; Turnbull TL; LaPrade CM; Nitri M; Wijdicks CA; LaPrade RF
    Am J Sports Med; 2016 Mar; 44(3):639-45. PubMed ID: 26646516
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Analysis of a new all-inside versus inside-out technique for repairing radial meniscal tears.
    Beamer BS; Masoudi A; Walley KC; Harlow ER; Manoukian OS; Hertz B; Haeussler C; Olson JJ; Deangelis JP; Nazarian A; Ramappa AJ
    Arthroscopy; 2015 Feb; 31(2):293-8. PubMed ID: 25312766
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The Biomechanical Performance of the Latest All-Inside Meniscal Repair Devices.
    Barber FA; Howard MS; Ashraf W; Spenciner DB
    Arthroscopy; 2020 Dec; 36(12):3001-3007. PubMed ID: 32315765
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Several Techniques Exist With Favorable Biomechanical Outcomes in Radial Meniscus Tear Repair-A Systematic Review.
    Oosten J; Yoder R; DiBartola A; Bowler J; Sparks A; Duerr R; Magnussen R; Kaeding C; Flanigan D
    Arthroscopy; 2022 Aug; 38(8):2557-2578.e4. PubMed ID: 35189305
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Biomechanical evaluation of different suture techniques for arthroscopic transtibial pull-out repair of posterior medial meniscus root tears.
    Feucht MJ; Grande E; Brunhuber J; Burgkart R; Imhoff AB; Braun S
    Am J Sports Med; 2013 Dec; 41(12):2784-90. PubMed ID: 24013348
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of all-inside meniscal repair devices with matched inside-out suture repair.
    Rosso C; Kovtun K; Dow W; McKenzie B; Nazarian A; DeAngelis JP; Ramappa AJ
    Am J Sports Med; 2011 Dec; 39(12):2634-9. PubMed ID: 21997730
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biomechanical Comparison of 3 Novel Repair Techniques for Radial Tears of the Medial Meniscus: The 2-Tunnel Transtibial Technique, a "Hybrid" Horizontal and Vertical Mattress Suture Configuration, and a Combined "Hybrid Tunnel" Technique.
    Buckley PS; Kemler BR; Robbins CM; Aman ZS; Storaci HW; Dornan GJ; LaPrade RF
    Am J Sports Med; 2019 Mar; 47(3):651-658. PubMed ID: 30624953
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A simple cinch is superior to a locking loop for meniscus root repair: a human biomechanical comparison of suture constructs in a transtibial pull-out model.
    Krych AJ; Johnson NR; Wu IT; Smith PA; Stuart MJ
    Knee Surg Sports Traumatol Arthrosc; 2018 Aug; 26(8):2239-2244. PubMed ID: 28748490
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Primary Fixation and Cyclic Performance of Single-Stitch All-Inside and Inside-Out Meniscal Devices for Repairing Vertical Longitudinal Meniscal Tears.
    Bachmaier S; Krych AJ; Smith PA; Herbort M; Ritter D; LaPrade RF; Wijdicks CA
    Am J Sports Med; 2022 Aug; 50(10):2705-2713. PubMed ID: 35787211
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Tibiofemoral Contact Mechanics After Horizontal or Ripstop Suture in Inside-Out and Transtibial Repair for Meniscus Radial Tears in a Porcine Model.
    Zhang HZ; Zhou YF; Li WP; Luo H; Wu JT; Jiang C; Chen Z; Hou JY; Yang R; Song B; Zhang ZZ
    Arthroscopy; 2021 Mar; 37(3):932-940.e2. PubMed ID: 33227321
    [TBL] [Abstract][Full Text] [Related]  

  • 13. New suture method for radial tears of the meniscus: biomechanical analysis of cross-suture and double horizontal suture techniques using cyclic load testing.
    Matsubara H; Okazaki K; Izawa T; Tashiro Y; Matsuda S; Nishimura T; Nakanishi Y; Kawamura H; Iwamoto Y
    Am J Sports Med; 2012 Feb; 40(2):414-8. PubMed ID: 22016457
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cyclic test comparison of all-inside device and inside-out sutures for radial meniscus lesion repair: an in vitro porcine model study.
    Lee YH; Nyland J; Burden R; Caborn DN
    Arthroscopy; 2012 Dec; 28(12):1873-81. PubMed ID: 23085200
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Strategies for repair of radial tears close to the meniscal rim--biomechanical analysis with a cyclic loading protocol.
    Herbort M; Siam S; Lenschow S; Petersen W; Zantop T
    Am J Sports Med; 2010 Nov; 38(11):2281-7. PubMed ID: 20889985
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biomechanical evaluation of an all-inside suture-based device for repairing longitudinal meniscal tears.
    Masoudi A; Beamer BS; Harlow ER; Manoukian OS; Walley KC; Hertz B; Haeussler C; Olson JJ; Zurakowski D; Nazarian A; Ramappa AJ; DeAngelis JP
    Arthroscopy; 2015 Mar; 31(3):428-34. PubMed ID: 25442653
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Repair of peripheral vertical meniscus lesions in porcine menisci: in vitro biomechanical testing of 3 different meniscus repair devices.
    Lee YH; Nyland J; Burden R; Caborn DN
    Am J Sports Med; 2013 May; 41(5):1074-81. PubMed ID: 23475943
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A biomechanical evaluation of all-inside 2-stitch meniscal repair devices with matched inside-out suture repair.
    Ramappa AJ; Chen A; Hertz B; Wexler M; Grimaldi Bournissaint L; DeAngelis JP; Nazarian A
    Am J Sports Med; 2014 Jan; 42(1):194-9. PubMed ID: 24114752
    [TBL] [Abstract][Full Text] [Related]  

  • 19. All-inside meniscal repair devices compared with their matched inside-out vertical mattress suture repair: introducing 10,000 and 100,000 loading cycles.
    Rosso C; Müller S; Buckland DM; Schwenk T; Zimmermann S; de Wild M; Valderrabano V
    Am J Sports Med; 2014 Sep; 42(9):2226-33. PubMed ID: 24966304
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Radial Tears of the Lateral Meniscus-Two Novel Repair Techniques: A Biomechanical Study.
    Stender ZC; Cracchiolo AM; Walsh MP; Patterson DP; Wilusz MJ; Lemos SE
    Orthop J Sports Med; 2018 Apr; 6(4):2325967118768086. PubMed ID: 29780840
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.