187 related articles for article (PubMed ID: 32515166)
41. Time-resolved optically stimulated luminescence of Al2O3:C for ion beam therapy dosimetry.
Yukihara EG; Doull BA; Ahmed M; Brons S; Tessonnier T; Jäkel O; Greilich S
Phys Med Biol; 2015 Sep; 60(17):6613-38. PubMed ID: 26270884
[TBL] [Abstract][Full Text] [Related]
42. Comparison of the IAEA TRS-398 and AAPM TG-51 absorbed dose to water protocols in the dosimetry of high-energy photon and electron beams.
Huq MS; Andreo P; Song H
Phys Med Biol; 2001 Nov; 46(11):2985-3006. PubMed ID: 11720359
[TBL] [Abstract][Full Text] [Related]
43. Dose-response dependencies of OSL dosimeters in conventional linacs and 1.5T MR-linacs: an experimental and Monte Carlo study.
Episkopakis A; Margaroni V; Kanellopoulou S; Marinos N; Koutsouveli E; Karaiskos P; Pappas EP
Phys Med Biol; 2023 Nov; 68(22):. PubMed ID: 37857285
[No Abstract] [Full Text] [Related]
44. DEVELOPMENTS IN THE USE OF THERMOLUMINESCENCE AND OPTICALLY STIMULATED LUMINESCENCE FROM MOBILE PHONES IN EMERGENCY DOSIMETRY.
McKeever SWS; Sholom S; Chandler JR
Radiat Prot Dosimetry; 2020 Dec; 192(2):205-235. PubMed ID: 33406531
[TBL] [Abstract][Full Text] [Related]
45. The effect of different bleaching wavelengths on the sensitivity of Al(2)O(3):C optically stimulated luminescence detectors (OSLDs) exposed to 6 MV photon beams.
Omotayo AA; Cygler JE; Sawakuchi GO
Med Phys; 2012 Sep; 39(9):5457-68. PubMed ID: 22957613
[TBL] [Abstract][Full Text] [Related]
46. Optically stimulated luminescence in vivo dosimetry for radiotherapy: physical characterization and clinical measurements in (60)Co beams.
Mrčela I; Bokulić T; Izewska J; Budanec M; Fröbe A; Kusić Z
Phys Med Biol; 2011 Sep; 56(18):6065-82. PubMed ID: 21873767
[TBL] [Abstract][Full Text] [Related]
47. A reusable OSL-film for 2D radiotherapy dosimetry.
Wouter C; Dirk V; Paul L; Tom D
Phys Med Biol; 2017 Oct; 62(21):8441-8454. PubMed ID: 29047456
[TBL] [Abstract][Full Text] [Related]
48. Optically stimulated luminescence system as an alternative for radiochromic film for 2D reference dosimetry in UHDR electron beams.
Vanreusel V; Gasparini A; Galante F; Mariani G; Pacitti M; Colijn A; Reniers B; Yalvac B; Vandenbroucke D; Peeters M; Leblans P; Felici G; Verellen D; de Freitas Nascimento L
Phys Med; 2023 Oct; 114():103147. PubMed ID: 37804712
[TBL] [Abstract][Full Text] [Related]
49. A comparative validation of biodosimetry and physical dosimetry techniques for possible triage applications in emergency dosimetry.
Sholom S; McKeever SWS; Escalona MB; Ryan TL; Balajee AS
J Radiol Prot; 2022 Mar; 42(2):. PubMed ID: 35196651
[TBL] [Abstract][Full Text] [Related]
50. Investigation of a synthetic diamond detector response in kilovoltage photon beams.
Kaveckyte V; Persson L; Malusek A; Benmakhlouf H; Alm Carlsson G; Carlsson Tedgren Å
Med Phys; 2020 Mar; 47(3):1268-1279. PubMed ID: 31880809
[TBL] [Abstract][Full Text] [Related]
51. Characteristics of an OSLD in the diagnostic energy range.
Al-Senan RM; Hatab MR
Med Phys; 2011 Jul; 38(7):4396-405. PubMed ID: 21859040
[TBL] [Abstract][Full Text] [Related]
52. DEVELOPMENT OF OPTICALLY STIMULATED LUMINESCENCE BADGE READER SYSTEM FOR INDIVIDUAL MONITORING OF RADIATION WORKERS.
Mishra DR; Paliwal L; Sutar SS; Singh AK
Radiat Prot Dosimetry; 2020 Nov; 191(1):25-38. PubMed ID: 33098303
[TBL] [Abstract][Full Text] [Related]
53. IAEA/WHO postal dosimetry audit methodology for electron beams using radio photoluminescent dosimeters.
Dimitriadis A; Kazantsev P; Chelminski K; Titovich E; Naida E; Magnus T; Meghzifene A; Azangwe G; Carrara M; Swamidas J
Med Phys; 2023 Nov; 50(11):7214-7221. PubMed ID: 37793099
[TBL] [Abstract][Full Text] [Related]
54. Application of the optically stimulated luminescence (OSL) technique for mouse dosimetry in micro-CT imaging.
Vrigneaud JM; Courteau A; Ranouil J; Morgand L; Raguin O; Walker P; Oudot A; Collin B; Brunotte F
Med Phys; 2013 Dec; 40(12):122102. PubMed ID: 24320529
[TBL] [Abstract][Full Text] [Related]
55. The energy dependence of lithium formate EPR dosimeters for clinical electron beams.
Malinen E; Waldeland E; Hole EO; Sagstuen E
Phys Med Biol; 2007 Jul; 52(14):4361-9. PubMed ID: 17664613
[TBL] [Abstract][Full Text] [Related]
56. Characterisation of energy response of Al(2)O(3):C optically stimulated luminescent dosemeters (OSLDs) using cavity theory.
Scarboro SB; Kry SF
Radiat Prot Dosimetry; 2013 Jan; 153(1):23-31. PubMed ID: 22653437
[TBL] [Abstract][Full Text] [Related]
57. Recommendations for clinical electron beam dosimetry: supplement to the recommendations of Task Group 25.
Gerbi BJ; Antolak JA; Deibel FC; Followill DS; Herman MG; Higgins PD; Huq MS; Mihailidis DN; Yorke ED; Hogstrom KR; Khan FM
Med Phys; 2009 Jul; 36(7):3239-79. PubMed ID: 19673223
[TBL] [Abstract][Full Text] [Related]
58. AAPM TG 191: Clinical use of luminescent dosimeters: TLDs and OSLDs.
Kry SF; Alvarez P; Cygler JE; DeWerd LA; Howell RM; Meeks S; O'Daniel J; Reft C; Sawakuchi G; Yukihara EG; Mihailidis D
Med Phys; 2020 Feb; 47(2):e19-e51. PubMed ID: 31574174
[TBL] [Abstract][Full Text] [Related]
59. Clinical radiation therapy measurements with a new commercial synthetic single crystal diamond detector.
Laub WU; Crilly R
J Appl Clin Med Phys; 2014 Nov; 15(6):4890. PubMed ID: 25493512
[TBL] [Abstract][Full Text] [Related]
60. Evaluation of SrAl
Tang X; Ehler ED; Brost E; Mathew DC
J Appl Clin Med Phys; 2021 May; 22(5):191-197. PubMed ID: 33951293
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]