These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 32517859)

  • 1. Modeling of braided stents: Comparison of geometry reconstruction and contact strategies.
    Zaccaria A; Migliavacca F; Pennati G; Petrini L
    J Biomech; 2020 Jun; 107():109841. PubMed ID: 32517859
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Numerical investigations of the mechanical properties of braided vascular stents.
    Fu W; Xia Q; Yan R; Qiao A
    Biomed Mater Eng; 2018; 29(1):81-94. PubMed ID: 29254075
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Numerical modeling of bare and polymer-covered braided stents using torsional and tensile springs connectors.
    Giuliodori A; Hernández JA; Fernandez-Sanchez D; Galve I; Soudah E
    J Biomech; 2021 Jun; 123():110459. PubMed ID: 34022531
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of computational modelling techniques for braided stent analysis.
    Kelly N; McGrath DJ; Sweeney CA; Kurtenbach K; Grogan JA; Jockenhoevel S; O'Brien BJ; Bruzzi M; McHugh PE
    Comput Methods Biomech Biomed Engin; 2019 Dec; 22(16):1334-1344. PubMed ID: 31502888
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Virtual optimization of self-expandable braided wire stents.
    De Beule M; Van Cauter S; Mortier P; Van Loo D; Van Impe R; Verdonck P; Verhegghe B
    Med Eng Phys; 2009 May; 31(4):448-53. PubMed ID: 19117791
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Looped ends versus open ends braided stent: A comparison of the mechanical behaviour using analytical and numerical methods.
    Shanahan C; Tiernan P; Tofail SAM
    J Mech Behav Biomed Mater; 2017 Nov; 75():581-591. PubMed ID: 28863400
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A finite element investigation on design parameters of bare and polymer-covered self-expanding wire braided stents.
    McKenna CG; Vaughan TJ
    J Mech Behav Biomed Mater; 2021 Mar; 115():104305. PubMed ID: 33454463
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Analytical methods for braided stents design and comparison with FEA.
    Zaccaria A; Pennati G; Petrini L
    J Mech Behav Biomed Mater; 2021 Jul; 119():104560. PubMed ID: 33930655
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Mechanical modeling of self-expandable stent fabricated using braiding technology.
    Kim JH; Kang TJ; Yu WR
    J Biomech; 2008 Nov; 41(15):3202-12. PubMed ID: 18804764
    [TBL] [Abstract][Full Text] [Related]  

  • 10. On the importance of modeling balloon folding, pleating, and stent crimping: An FE study comparing experimental inflation tests.
    Geith MA; Swidergal K; Hochholdinger B; Schratzenstaller TG; Wagner M; Holzapfel GA
    Int J Numer Method Biomed Eng; 2019 Nov; 35(11):e3249. PubMed ID: 31400057
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Self-expandable stent for thrombus removal modeling: Solid or beam finite elements?
    Luraghi G; Bridio S; Migliavacca F; Rodriguez Matas JF
    Med Eng Phys; 2022 Aug; 106():103836. PubMed ID: 35926960
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Numerical research on the biomechanical behaviour of braided stents with different end shapes and stent-oesophagus interaction.
    Ni XY; Zhang YH; Zhao HX; Pan CW
    Int J Numer Method Biomed Eng; 2018 Jun; 34(6):e2971. PubMed ID: 29461690
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An experimental investigation of the mechanical performance of PLLA wire-braided stents.
    Lucchetti A; Emonts C; Idrissi A; Gries T; Vaughan TJ
    J Mech Behav Biomed Mater; 2023 Feb; 138():105568. PubMed ID: 36459705
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A finite element simulation method to evaluate the crimpability of curved stents.
    Praveen Kumar G; Louis Commillus A; Cui F
    Med Eng Phys; 2019 Dec; 74():162-165. PubMed ID: 31635945
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Computational modeling of braided-stent deployment for interpreting the mechanism of stent flattening.
    Shiozaki S; Otani T; Fujimura S; Takao H; Wada S
    Int J Numer Method Biomed Eng; 2021 Dec; 37(12):e3335. PubMed ID: 32212324
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An in silico biomechanical analysis of the stent-esophagus interaction.
    Peirlinck M; Debusschere N; Iannaccone F; Siersema PD; Verhegghe B; Segers P; De Beule M
    Biomech Model Mechanobiol; 2018 Feb; 17(1):111-131. PubMed ID: 28819758
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Computer modeling of deployment and mechanical expansion of neurovascular flow diverter in patient-specific intracranial aneurysms.
    Ma D; Dargush GF; Natarajan SK; Levy EI; Siddiqui AH; Meng H
    J Biomech; 2012 Aug; 45(13):2256-63. PubMed ID: 22818662
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Design and evaluation of the crimping of a hooked self-expandable caval valve stent for the treatment of tricuspid regurgitation.
    Praveen Kumar G; Liang Leo H; Cui F
    Comput Methods Biomech Biomed Engin; 2019 Apr; 22(5):533-546. PubMed ID: 30773049
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Finite element methods to analyze helical stent expansion.
    Paryab N; Cronin DS; Lee-Sullivan P
    Int J Numer Method Biomed Eng; 2014 Mar; 30(3):339-52. PubMed ID: 24123985
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Design optimization of stent and its dilatation balloon using kriging surrogate model.
    Li H; Liu T; Wang M; Zhao D; Qiao A; Wang X; Gu J; Li Z; Zhu B
    Biomed Eng Online; 2017 Jan; 16(1):13. PubMed ID: 28086895
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.