259 related articles for article (PubMed ID: 32520014)
1. Cost-effective paper-based electrochemical immunosensor using a label-free assay for sensitive detection of ferritin.
Boonkaew S; Teengam P; Jampasa S; Rengpipat S; Siangproh W; Chailapakul O
Analyst; 2020 Jul; 145(14):5019-5026. PubMed ID: 32520014
[TBL] [Abstract][Full Text] [Related]
2. Electrochemical immunosensor based on gold-labeled monoclonal anti-LipL32 for leptospirosis diagnosis.
Jampasa S; Lae-Ngee P; Patarakul K; Ngamrojanavanich N; Chailapakul O; Rodthongkum N
Biosens Bioelectron; 2019 Oct; 142():111539. PubMed ID: 31376713
[TBL] [Abstract][Full Text] [Related]
3. Toward the early diagnosis of tuberculosis: A gold particle-decorated graphene-modified paper-based electrochemical biosensor for Hsp16.3 detection.
Pornprom T; Phusi N; Thongdee P; Pakamwong B; Sangswan J; Kamsri P; Punkvang A; Suttisintong K; Leanpolchareanchai J; Hongmanee P; Lumjiaktase P; Jampasa S; Chailapakul O; Pungpo P
Talanta; 2024 Jan; 267():125210. PubMed ID: 37717539
[TBL] [Abstract][Full Text] [Related]
4. A Sensitive and Disposable Graphene Oxide Electrochemical Immunosensor for Label-free Detection of Human Immunoglobulin G.
Jumpathong W; Jakmunee J; Ounnunkad K
Anal Sci; 2016; 32(3):323-8. PubMed ID: 26960613
[TBL] [Abstract][Full Text] [Related]
5. Microfluidic-Based Electrochemical Immunosensing of Ferritin.
Garg M; Christensen MG; Iles A; Sharma AL; Singh S; Pamme N
Biosensors (Basel); 2020 Aug; 10(8):. PubMed ID: 32764518
[TBL] [Abstract][Full Text] [Related]
6. A novel ultrasensitive immunosensor based on disposable graphite paper electrodes for troponin T detection in cardiovascular disease.
Demirbakan B; Kemal Sezgintürk M
Talanta; 2020 Jun; 213():120779. PubMed ID: 32200916
[TBL] [Abstract][Full Text] [Related]
7. Cost-Effective and Handmade Paper-Based Immunosensing Device for Electrochemical Detection of Influenza Virus.
Devarakonda S; Singh R; Bhardwaj J; Jang J
Sensors (Basel); 2017 Nov; 17(11):. PubMed ID: 29137115
[TBL] [Abstract][Full Text] [Related]
8. An ultrasensitive label-free electrochemical immunosensor based on 3D porous chitosan-graphene-ionic liquid-ferrocene nanocomposite cryogel decorated with gold nanoparticles for prostate-specific antigen.
Choosang J; Khumngern S; Thavarungkul P; Kanatharana P; Numnuam A
Talanta; 2021 Mar; 224():121787. PubMed ID: 33379016
[TBL] [Abstract][Full Text] [Related]
9. Label-free Paper-based Immunosensor with Graphene Nanocomposites for Electrochemical Detection of Follicle-stimulating Hormone.
Luo J; Kong Z; Wang Y; Xie J; Liu J; Jin H; Cai X
Annu Int Conf IEEE Eng Med Biol Soc; 2018 Jul; 2018():2901-2904. PubMed ID: 30441007
[TBL] [Abstract][Full Text] [Related]
10. Investigate electrochemical immunosensor of cortisol based on gold nanoparticles/magnetic functionalized reduced graphene oxide.
Sun B; Gou Y; Ma Y; Zheng X; Bai R; Ahmed Abdelmoaty AA; Hu F
Biosens Bioelectron; 2017 Feb; 88():55-62. PubMed ID: 27499382
[TBL] [Abstract][Full Text] [Related]
11. A novel label-free microfluidic paper-based immunosensor for highly sensitive electrochemical detection of carcinoembryonic antigen.
Wang Y; Xu H; Luo J; Liu J; Wang L; Fan Y; Yan S; Yang Y; Cai X
Biosens Bioelectron; 2016 Sep; 83():319-26. PubMed ID: 27132007
[TBL] [Abstract][Full Text] [Related]
12. Graphene nanosheets as an electric mediator for ultrafast sensing of urokinase plasminogen activator receptor-A biomarker of cancer.
Roberts A; Tripathi PP; Gandhi S
Biosens Bioelectron; 2019 Sep; 141():111398. PubMed ID: 31176112
[TBL] [Abstract][Full Text] [Related]
13. Redox probe-free electrochemical immunosensor utilizing electropolymerized melamine on reduced graphene oxide for the point-of-care diagnosis of gastric cancer.
Kanagavalli P; Eissa S
Talanta; 2024 Apr; 270():125549. PubMed ID: 38157735
[TBL] [Abstract][Full Text] [Related]
14. A sensitive and disposable electrochemical immunosensor for detection of SOX2, a biomarker of cancer.
Aydın EB; Sezgintürk MK
Talanta; 2017 Sep; 172():162-170. PubMed ID: 28602290
[TBL] [Abstract][Full Text] [Related]
15. Au nanoparticles/PAMAM dendrimer functionalized wired ethyleneamine-viologen as highly efficient interface for ultra-sensitive α-fetoprotein electrochemical immunosensor.
Kavosi B; Hallaj R; Teymourian H; Salimi A
Biosens Bioelectron; 2014 Sep; 59():389-96. PubMed ID: 24755256
[TBL] [Abstract][Full Text] [Related]
16. A paper-based electrochemical immunosensor with reduced graphene oxide/thionine/gold nanoparticles nanocomposites modification for the detection of cancer antigen 125.
Fan Y; Shi S; Ma J; Guo Y
Biosens Bioelectron; 2019 Jun; 135():1-7. PubMed ID: 30981027
[TBL] [Abstract][Full Text] [Related]
17. Boron nitride nanosheet modified label-free electrochemical immunosensor for cancer antigen 125 detection.
Öndeş B; Evli S; Uygun M; Aktaş Uygun D
Biosens Bioelectron; 2021 Nov; 191():113454. PubMed ID: 34171737
[TBL] [Abstract][Full Text] [Related]
18. Multiplexed label-free electrochemical immunosensor for breast cancer precision medicine.
Cotchim S; Thavarungkul P; Kanatharana P; Limbut W
Anal Chim Acta; 2020 Sep; 1130():60-71. PubMed ID: 32892939
[TBL] [Abstract][Full Text] [Related]
19. Biocompatible epoxysilane substituted polymer-based nano biosensing platform for label-free detection of cancer biomarker SP17 in patient serum samples.
Yadav AK; Verma D; Kumar A; Bhatt AN; Solanki PR
Int J Biol Macromol; 2023 Jun; 239():124325. PubMed ID: 37054852
[TBL] [Abstract][Full Text] [Related]
20. Ultrasensitive Nanoimmunosensor by coupling non-covalent functionalized graphene oxide platform and numerous ferritin labels on carbon nanotubes.
Akter R; Jeong B; Choi JS; Rahman MA
Biosens Bioelectron; 2016 Jun; 80():123-130. PubMed ID: 26820360
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]