BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 32545683)

  • 1. Simultaneous Measurement of Glomerular Filtration Rate, Effective Renal Plasma Flow and Tubular Secretion in Different Poultry Species by Single Intravenous Bolus of Iohexol and Para-Aminohippuric Acid.
    Stroobant L; Croubels S; Dhondt L; Millecam J; De Baere S; Gasthuys E; Morrens J; Antonissen G
    Animals (Basel); 2020 Jun; 10(6):. PubMed ID: 32545683
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurement of glomerular filtration rate and effective renal plasma flow in the conscious beagle dog by single intravenous bolus of iohexol and p-aminohippuric acid.
    Laroute V; Lefebvre HP; Costes G; Toutain PL
    J Pharmacol Toxicol Methods; 1999 Feb; 41(1):17-25. PubMed ID: 10507754
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Simple HPLC-UV method for determination of iohexol, iothalamate, p-aminohippuric acid and n-acetyl-p-aminohippuric acid in human plasma and urine with ERPF, GFR and ERPF/GFR ratio determination using colorimetric analysis.
    Farthing D; Sica DA; Fakhry I; Larus T; Ghosh S; Farthing C; Vranian M; Gehr T
    J Chromatogr B Analyt Technol Biomed Life Sci; 2005 Nov; 826(1-2):267-72. PubMed ID: 16169291
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Conventional Pig as Animal Model for Human Renal Drug Excretion Processes: Unravelling the Porcine Renal Function by Use of a Cocktail of Exogenous Markers.
    Dhondt L; Croubels S; De Paepe P; Wallis SC; Pandey S; Roberts JA; Lipman J; De Cock P; Devreese M
    Front Pharmacol; 2020; 11():883. PubMed ID: 32595506
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparative physiology of glomerular filtration rate by plasma clearance of exogenous creatinine and exo-iohexol in six different avian species.
    Gasthuys E; Montesinos A; Caekebeke N; Devreese M; De Baere S; Ardiaca M; Paepe D; Croubels S; Antonissen G
    Sci Rep; 2019 Dec; 9(1):19699. PubMed ID: 31873143
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A new HPLC method to determine glomerular filtration rate and effective renal plasma flow in conscious dogs by single intravenous administration of iohexol and p-aminohippuric acid.
    Meucci V; Gasperini A; Soldani G; Guidi G; Giorgi M
    J Chromatogr Sci; 2004 Feb; 42(2):107-11. PubMed ID: 15023265
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A novel, simple and inexpensive procedure for the simultaneous determination of iopamidol and p-aminohippuric acid for renal function assessment from plasma samples in awake rats.
    Rodríguez-Romero V; González-Villalva KI; Reyes JL; Franco-Bourland RE; Guízar-Sahagún G; Castañeda-Hernández G; Cruz-Antonio L
    J Pharm Biomed Anal; 2015 Mar; 107():196-203. PubMed ID: 25594899
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development and validation of an ultra-high performance liquid chromatography-tandem mass spectrometry method for the simultaneous determination of iohexol, p-aminohippuric acid and creatinine in porcine and broiler chicken plasma.
    Dhondt L; Croubels S; De Cock P; De Paepe P; De Baere S; Devreese M
    J Chromatogr B Analyt Technol Biomed Life Sci; 2019 Jun; 1117():77-85. PubMed ID: 31004849
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of two intravenous single-bolus methods for measuring effective renal plasma flow.
    Hirata-Dulas CA; Awni WM; Matzke GR; Halstenson CE; Guay DR
    Am J Kidney Dis; 1994 Mar; 23(3):374-81. PubMed ID: 8128938
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Use of a single injection solute-clearance method for determination of glomerular filtration rate and effective renal plasma flow in chickens.
    Radin MJ; Hoepf TM; Swayne DE
    Lab Anim Sci; 1993 Dec; 43(6):594-6. PubMed ID: 8158986
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A comparison of inulin, para-aminohippuric acid, and endogenous creatinine clearances as measures of renal function in neonatal foals.
    Brewer BD; Clement SF; Lotz WS; Gronwall R
    J Vet Intern Med; 1990; 4(6):301-5. PubMed ID: 2074554
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Renal function and magnesium clearance in young and old cows given potassium chloride and sodium citrate.
    Deetz LE; Tucker RE; Mitchell GE; DeGregorio RM
    J Anim Sci; 1982 Sep; 55(3):680-9. PubMed ID: 7130070
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Chromatographic estimation of iothalamate and p-aminohippuric acid to measure glomerular filtration rate and effective renal plasma flow in humans.
    Agarwal R
    J Chromatogr B Biomed Sci Appl; 1998 Jan; 705(1):3-9. PubMed ID: 9498664
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Whole-body insulin clearance in people with type 2 diabetes and normal kidney function: Relationship with glomerular filtration rate, renal plasma flow, and insulin sensitivity.
    van Baar MJB; van Bommel EJM; Smits MM; Touw DJ; Nieuwdorp M; Ten Kate RW; Joles JA; van Raalte DH
    J Diabetes Complications; 2022 Apr; 36(4):108166. PubMed ID: 35221224
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Influence of glomerular filtration rate on renal PAH secretion rate in the rat kidney. Dependency of PAH extraction on renal filtration fraction.
    Häberle DA; Ruhland G; Lausser A; Moore L; Neiss A
    Pflugers Arch; 1978 Jul; 375(2):131-9. PubMed ID: 567783
    [TBL] [Abstract][Full Text] [Related]  

  • 16. How to assess glomerular function and damage in humans.
    Rahn KH; Heidenreich S; Brückner D
    J Hypertens; 1999 Mar; 17(3):309-17. PubMed ID: 10100067
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A phase 1 study to evaluate the effect of dolutegravir on renal function via measurement of iohexol and para-aminohippurate clearance in healthy subjects.
    Koteff J; Borland J; Chen S; Song I; Peppercorn A; Koshiba T; Cannon C; Muster H; Piscitelli SC
    Br J Clin Pharmacol; 2013 Apr; 75(4):990-6. PubMed ID: 22905856
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dynamic renal blood flow measurement by positron emission tomography in patients with CRF.
    Juillard L; Janier MF; Fouque D; Cinotti L; Maakel N; Le Bars D; Barthez PY; Pozet N; Laville M
    Am J Kidney Dis; 2002 Nov; 40(5):947-54. PubMed ID: 12407639
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Clearance of iohexol, 51Cr-EDTA and endogenous creatinine for determination of glomerular filtration rate in pigs with reduced renal function: a comparison between different clearance techniques.
    Frennby B; Sterner G; Almén T; Chai CM; Jönsson BA; Månsson S
    Scand J Clin Lab Invest; 1997 May; 57(3):241-52. PubMed ID: 9238760
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Simultaneous administration of a cocktail of markers to measure renal drug elimination pathways: absence of a pharmacokinetic interaction between fluconazole and sinistrin, p-aminohippuric acid and pindolol.
    Gross AS; McLachlan AJ; Minns I; Beal JB; Tett SE
    Br J Clin Pharmacol; 2001 Jun; 51(6):547-55. PubMed ID: 11422014
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.