These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

191 related articles for article (PubMed ID: 32549958)

  • 1. Adjustable Loop Femoral Cortical Suspension Devices for Anterior Cruciate Ligament Reconstruction: A Systematic Review.
    Singh S; Shaunak S; Shaw SCK; Anderson JL; Mandalia V
    Indian J Orthop; 2020 Jul; 54(4):426-443. PubMed ID: 32549958
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Clinical and Radiological Outcomes After Hamstring Anterior Cruciate Ligament Reconstructions: Comparison Between Fixed-Loop and Adjustable-Loop Cortical Suspension Devices.
    Choi NH; Yang BS; Victoroff BN
    Am J Sports Med; 2017 Mar; 45(4):826-831. PubMed ID: 27881383
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A biomechanical comparison of femoral cortical suspension devices for soft tissue anterior cruciate ligament reconstruction under high loads.
    Johnson JS; Smith SD; LaPrade CM; Turnbull TL; LaPrade RF; Wijdicks CA
    Am J Sports Med; 2015 Jan; 43(1):154-60. PubMed ID: 25326014
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical Testing of Three Alternative Quadrupled Tendon Graft Constructs With Adjustable Loop Suspensory Fixation for Anterior Cruciate Ligament Reconstruction Compared With Four-Strand Grafts Fixed With Screws and Femoral Fixed Loop Devices.
    Vertullo CJ; Piepenbrink M; Smith PA; Wilson AJ; Wijdicks CA
    Am J Sports Med; 2019 Mar; 47(4):828-836. PubMed ID: 30789779
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Magnetic Resonance Imaging and Clinical Results of Outside-in Anterior Cruciate Ligament Reconstruction: A Comparison of Fixed- and Adjustable-Length Loop Cortical Fixation.
    Ahn JH; Ko TS; Lee YS; Jeong HJ; Park JK
    Clin Orthop Surg; 2018 Jun; 10(2):157-166. PubMed ID: 29854338
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Femoral suspension devices for anterior cruciate ligament reconstruction: do adjustable loops lengthen?
    Barrow AE; Pilia M; Guda T; Kadrmas WR; Burns TC
    Am J Sports Med; 2014 Feb; 42(2):343-9. PubMed ID: 24158183
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Clinical Outcome of Fixed Versus Adjustable Loop Cortical Suspension Devices in Arthroscopic Anterior Cruciate Ligament Reconstruction.
    Mohamed RSAA; El-Din El-Shafie MH; El-Sheikh MA
    Ortop Traumatol Rehabil; 2020 Jun; 22(3):181-185. PubMed ID: 32732442
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fixed- Versus Adjustable-Loop Femoral Cortical Suspension Devices for Anterior Cruciate Ligament Reconstruction: A Systematic Review and Meta-analysis of Biomechanical Studies.
    Houck DA; Kraeutler MJ; McCarty EC; Bravman JT
    Orthop J Sports Med; 2018 Oct; 6(10):2325967118801762. PubMed ID: 30364394
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Loop Length Change of an Adjustable-Length Femoral Cortical Suspension Device in Anatomic Rectangular Tunnel Anterior Cruciate Ligament Reconstruction With a Bone-Patellar Tendon-Bone Graft and Associated Clinical Outcomes.
    Kusano M; Kazui A; Uchida R; Mae T; Tsuda T; Toritsuka Y
    Arthroscopy; 2018 Nov; 34(11):3063-3070. PubMed ID: 30301633
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Does adjustable-loop femoral cortical suspension loosen after anterior cruciate ligament reconstruction? A retrospective comparative study.
    Boyle MJ; Vovos TJ; Walker CG; Stabile KJ; Roth JM; Garrett WE
    Knee; 2015 Sep; 22(4):304-8. PubMed ID: 25999126
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Assessment of fixation for anterior cruciate ligament reconstruction using oversized suspensory devices on full-length femoral tunnels.
    Prado-Nóvoa M; Pérez-Blanca A; Espejo-Reina A; Lombardo-Torre M; Ezquerro-Juanco F; Espejo-Baena A
    Clin Biomech (Bristol, Avon); 2020 Jun; 76():105008. PubMed ID: 32413774
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A Comparative Biomechanical Study of Femoral Cortical Suspension Devices for Soft-Tissue Anterior Cruciate Ligament Reconstruction: Adjustable-Length Loop Versus Fixed-Length Loop.
    Chang MJ; Bae TS; Moon YW; Ahn JH; Wang JH
    Arthroscopy; 2018 Feb; 34(2):566-572. PubMed ID: 29146163
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Adjustable-Loop Femoral Cortical Suspensory Fixation for Patellar Tendon Anterior Cruciate Ligament Reconstruction: A Time Zero Biomechanical Comparison With Interference Screw Fixation.
    Mickelson DT; Lefebvre T; Gall K; Riboh JC
    Am J Sports Med; 2018 Jul; 46(8):1857-1862. PubMed ID: 29763336
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Can an adjustable-loop length suspensory fixation device reduce femoral tunnel enlargement in anterior cruciate ligament reconstruction? A prospective computer tomography study.
    Lanzetti RM; Monaco E; De Carli A; Grasso A; Ciompi A; Sigillo R; Argento G; Ferretti A
    Knee; 2016 Oct; 23(5):837-41. PubMed ID: 27338510
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Mechanical Properties of an Adjustable-Loop Cortical Suspension Device for Anterior Cruciate Ligament Reconstruction.
    Iuchi R; Mae T; Tachibana Y; Shino K; Nakagawa S; Yoshikawa H; Nakata K
    Orthop J Sports Med; 2018 Aug; 6(8):2325967118791183. PubMed ID: 30151403
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Adjustable- Versus Fixed-Loop Devices for Femoral Fixation in ACL Reconstruction: An In Vitro Full-Construct Biomechanical Study of Surgical Technique-Based Tibial Fixation and Graft Preparation.
    Smith PA; Piepenbrink M; Smith SK; Bachmaier S; Bedi A; Wijdicks CA
    Orthop J Sports Med; 2018 Apr; 6(4):2325967118768743. PubMed ID: 29780843
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Femoral cortical suspension devices for soft tissue anterior cruciate ligament reconstruction: a comparative biomechanical study.
    Petre BM; Smith SD; Jansson KS; de Meijer PP; Hackett TR; LaPrade RF; Wijdicks CA
    Am J Sports Med; 2013 Feb; 41(2):416-22. PubMed ID: 23263298
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Biomechanical and Computed Tomography Analysis of Adjustable Femoral Cortical Fixation Devices for Anterior Cruciate Ligament Reconstruction in a Cadaveric Human Knee Model.
    Born TR; Biercevicz AM; Koruprolu SC; Paller D; Spenciner D; Fadale PD
    Arthroscopy; 2016 Feb; 32(2):253-61. PubMed ID: 26814387
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Does loop length change after anterior cruciate ligament reconstruction with adjustable loop cortical suspension device?: Observation of the hamstring graft completely filling the femoral tunnel.
    Hyodo K; Kanamori A; Watanabe R; Ainoya T; Kikuchi N; Arai N; Yamazaki M
    J Exp Orthop; 2023 Jul; 10(1):67. PubMed ID: 37393331
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biomechanical comparison of 2 anterior cruciate ligament graft preparation techniques for tibial fixation: adjustable-length loop cortical button or interference screw.
    Mayr R; Heinrichs CH; Eichinger M; Coppola C; Schmoelz W; Attal R
    Am J Sports Med; 2015 Jun; 43(6):1380-5. PubMed ID: 25767269
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.