These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

176 related articles for article (PubMed ID: 32553353)

  • 1. Au/CeO
    Ouyang X; Tang L; Feng C; Peng B; Liu Y; Ren X; Zhu X; Tan J; Hu X
    Biosens Bioelectron; 2020 Sep; 164():112328. PubMed ID: 32553353
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A novel near-infrared light-responsive photoelectrochemical platform for detecting microcystin-LR in fish based on Ag
    Zheng C; Yin M; Su B; Peng A; Guo Z; Chen X; Chen X
    Talanta; 2021 Jan; 221():121447. PubMed ID: 33076071
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Enhanced photoelectric conversion efficiency: A novel h-BN based self-powered photoelectrochemical aptasensor for ultrasensitive detection of diazinon.
    Tan J; Peng B; Tang L; Feng C; Wang J; Yu J; Ouyang X; Zhu X
    Biosens Bioelectron; 2019 Oct; 142():111546. PubMed ID: 31387026
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Visible light-activated self-powered photoelectrochemical aptasensor for ultrasensitive chloramphenicol detection based on DFT-proved Z-scheme Ag
    Peng B; Lu Y; Luo J; Zhang Z; Zhu X; Tang L; Wang L; Deng Y; Ouyang X; Tan J; Wang J
    J Hazard Mater; 2021 Jan; 401():123395. PubMed ID: 32653796
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Fabricating photoelectrochemical aptasensor for selectively monitoring microcystin-LR residues in fish based on visible light-responsive BiOBr nanoflakes/N-doped graphene photoelectrode.
    Du X; Jiang D; Dai L; Zhou L; Hao N; Qian J; Qiu B; Wang K
    Biosens Bioelectron; 2016 Jul; 81():242-248. PubMed ID: 26963789
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Highly sensitive detection of microcystin-LR under visible light using a self-powered photoelectrochemical aptasensor based on a CoO/Au/g-C
    Tang L; Ouyang X; Peng B; Zeng G; Zhu Y; Yu J; Feng C; Fang S; Zhu X; Tan J
    Nanoscale; 2019 Jul; 11(25):12198-12209. PubMed ID: 31199416
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ultrasensitive photoelectrochemical microcystin-LR immunosensor using carboxyl-functionalized graphene oxide enhanced gold nanoclusters for signal amplification.
    Fan L; Xiao G; Wang M; Zhao S; Yang Q; Cheng L; Huang JJ; Yue Z
    Anal Chim Acta; 2021 Nov; 1185():339078. PubMed ID: 34711309
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A photoelectrochemical aptasensor constructed with core-shell CuS-TiO
    Tang Y; Chai Y; Liu X; Li L; Yang L; Liu P; Zhou Y; Ju H; Cheng Y
    Biosens Bioelectron; 2018 Oct; 117():224-231. PubMed ID: 29906770
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Visible-light triggered self-breathing-like dual-photoelectrode internal-driven self-powered sensor: Metal-ligand charge transfer (MLCT) induced signal-off strategy for the microcystin-LR assay.
    Du X; Zhang B; Jiang D; Sun J
    Biosens Bioelectron; 2020 Oct; 165():112414. PubMed ID: 32729533
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Visible light-driven self-powered aptasensors for ultrasensitive Microcystin-LR detection based on the carrier density effect of N-doped graphene hydrogel/hematite Schottky junctions.
    Zhang L; Jiang D; Shan X; Du X; Wei M; Zhang Y; Chen Z
    Analyst; 2021 Oct; 146(20):6220-6227. PubMed ID: 34523620
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Self-Powered Photoelectrochemical Aptasensor for Oxytetracycline Cathodic Detection Based on a Dual Z-Scheme WO
    Peng B; Zhang Z; Tang L; Ouyang X; Zhu X; Chen L; Fan X; Zhou Z; Wang J
    Anal Chem; 2021 Jul; 93(26):9129-9138. PubMed ID: 34152736
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Co
    Chen Y; Wang Y; Yan P; Ouyang Q; Dong J; Qian J; Chen J; Xu L; Li H
    Anal Chim Acta; 2020 Aug; 1125():299-307. PubMed ID: 32674777
    [TBL] [Abstract][Full Text] [Related]  

  • 13. CdTe QD-CeO
    Li M; Liang W; Yuan R; Chai Y
    ACS Appl Mater Interfaces; 2019 Mar; 11(12):11834-11840. PubMed ID: 30855130
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Self-powered Aptasensors Made with the In
    Yan T; Ding H; Feng R; Yuan R; Zhao Y; Sun M; Yan L; Wei Q
    ACS Appl Mater Interfaces; 2022 Jun; 14(22):25308-25316. PubMed ID: 35611402
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A flexible photoelectrochemical aptasensor using heterojunction architecture of α-Fe
    Ouyang X; Feng C; Tang L; Zhu X; Peng B; Fan X; Liao Y; Zhou Z; Zhang Z
    Biosens Bioelectron; 2022 Feb; 197():113734. PubMed ID: 34736113
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Enhanced cathodic electrochemiluminescent microcystin-LR aptasensor based on surface plasmon resonance of Bi nanoparticles.
    Yuan R; Liu Q; Hong H; Ma H; Xiao L; Li Y; Jiang D; Hao N; Wang K
    J Hazard Mater; 2022 Jul; 434():128877. PubMed ID: 35427978
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Engineering of Heterojunction-Mediated Biointerface for Photoelectrochemical Aptasensing: Case of Direct Z-Scheme CdTe-Bi
    Liu Q; Huan J; Hao N; Qian J; Mao H; Wang K
    ACS Appl Mater Interfaces; 2017 May; 9(21):18369-18376. PubMed ID: 28497956
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Gap-Tethered Au@AgAu Raman Tags for the Ratiometric Detection of MC-LR.
    Zhao Y; Zheng F; Ke W; Zhang W; Shi L; Liu H
    Anal Chem; 2019 Jun; 91(11):7162-7172. PubMed ID: 31066265
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A novel SERS-based aptasensor for ultrasensitive sensing of microcystin-LR.
    He D; Wu Z; Cui B; Jin Z
    Food Chem; 2019 Apr; 278():197-202. PubMed ID: 30583362
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Self-powered photoelectrochemical aptasensor based on phosphorus doped porous ultrathin g-C
    Peng B; Tang L; Zeng G; Fang S; Ouyang X; Long B; Zhou Y; Deng Y; Liu Y; Wang J
    Biosens Bioelectron; 2018 Dec; 121():19-26. PubMed ID: 30195118
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.