These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

166 related articles for article (PubMed ID: 32560309)

  • 21. Experimental evaluation of ultrasound higher-order harmonic imaging with Filtered-Delay Multiply And Sum (F-DMAS) non-linear beamforming.
    Matrone G; Ramalli A; Tortoli P; Magenes G
    Ultrasonics; 2018 May; 86():59-68. PubMed ID: 29398065
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Lag-Based Filtered-Delay Multiply and Sum Beamformer Combined with Two Phase-Related Factors for Medical Ultrasound Imaging.
    Song K; Liu P; Liu DC
    Comput Math Methods Med; 2020; 2020():1503791. PubMed ID: 32908575
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Evaluation of Image Reconstruction Algorithms for Confocal Microwave Imaging: Application to Patient Data.
    Elahi MA; O'Loughlin D; Lavoie BR; Glavin M; Jones E; Fear EC; O'Halloran M
    Sensors (Basel); 2018 May; 18(6):. PubMed ID: 29882893
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Efficient nonlinear beamformer based on P'th root of detected signals for linear-array photoacoustic tomography: application to sentinel lymph node imaging.
    Mozaffarzadeh M; Periyasamy V; Pramanik M; Makkiabadi B
    J Biomed Opt; 2018 Jul; 23(12):1-12. PubMed ID: 30054995
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Evaluating the Performance of Algorithms in Axillary Microwave Imaging towards Improved Breast Cancer Staging.
    Pato M; Eleutério R; Conceição RC; Godinho DM
    Sensors (Basel); 2023 Jan; 23(3):. PubMed ID: 36772536
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Iterative Model-Based Beamforming for High Dynamic Range Applications.
    Schlunk S; Dei K; Byram B
    IEEE Trans Ultrason Ferroelectr Freq Control; 2021 Mar; 68(3):482-493. PubMed ID: 32746227
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Weighted non-linear beamformers for low cost 2-element receive ultrasound imaging system.
    Vayyeti A; Thittai AK
    Ultrasonics; 2021 Feb; 110():106293. PubMed ID: 33130360
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Sparsity-based beamforming to enhance two-dimensional linear-array photoacoustic tomography.
    Paridar R; Mozaffarzadeh M; Periyasamy V; Pramanik M; Mehrmohammadi M; Orooji M
    Ultrasonics; 2019 Jul; 96():55-63. PubMed ID: 31005780
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Higher-order correlation based real-time beamforming in photoacoustic imaging.
    Mulani S; Paul S; Singh MS
    J Opt Soc Am A Opt Image Sci Vis; 2022 Oct; 39(10):1805-1814. PubMed ID: 36215552
    [TBL] [Abstract][Full Text] [Related]  

  • 30. GPU-accelerated Double-stage Delay-multiply-and-sum Algorithm for Fast Photoacoustic Tomography Using LED Excitation and Linear Arrays.
    Miri Rostami SR; Mozaffarzadeh M; Ghaffari-Miab M; Hariri A; Jokerst J
    Ultrason Imaging; 2019 Sep; 41(5):301-316. PubMed ID: 31322057
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Signal restoration algorithm for photoacoustic imaging systems.
    Hakakzadeh S; Amjadian M; Zhang Y; Mostafavi SM; Kavehvash Z; Wang L
    Biomed Opt Express; 2023 Feb; 14(2):651-666. PubMed ID: 36874483
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Photoacoustic tomography reconstruction using lag-based delay multiply and sum with a coherence factor improves in vivo ovarian cancer diagnosis.
    Yang G; Amidi E; Zhu Q
    Biomed Opt Express; 2021 Apr; 12(4):2250-2263. PubMed ID: 33996227
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Eigenspace-based minimum variance beamformer combined with sign coherence factor: Application to linear-array photoacoustic imaging.
    Shamekhi S; Periyasamy V; Pramanik M; Mehrmohammadi M; Mohammadzadeh Asl B
    Ultrasonics; 2020 Dec; 108():106174. PubMed ID: 32502893
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Optimally-weighted non-linear beamformer for conventional focused beam ultrasound imaging systems.
    Vayyeti A; Thittai AK
    Sci Rep; 2021 Nov; 11(1):21622. PubMed ID: 34732736
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Use of multi-angle ultra-wide band microwave sounding for high resolution breast imaging.
    Shipilov S; Eremeev A; Yakubov V; Fedyanin I; Satarov R; Zavyalova K; Shipilova S; Balzovsky E
    Med Phys; 2020 Oct; 47(10):5147-5157. PubMed ID: 32885421
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Real time breast microwave radar image reconstruction using circular holography: a study of experimental feasibility.
    Flores-Tapia D; Pistorius S
    Med Phys; 2011 Oct; 38(10):5420-31. PubMed ID: 21992361
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Microwave Imaging: Locating Bone Fractures using Patch Antenna of ISM Band.
    J JJS; Jahangeer GSB; Duraichi N; Logeshwaran M; Jeyapoornima B
    Curr Med Imaging; 2024 Feb; ():. PubMed ID: 38415465
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Ultrasound Baseband Delay-Multiply-and-Sum (BB-DMAS) nonlinear beamforming.
    Shen CC; Hsieh PY
    Ultrasonics; 2019 Jul; 96():165-174. PubMed ID: 30765204
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Ultrasound plane-wave imaging with delay multiply and sum beamforming and coherent compounding.
    Matrone G; Savoia AS; Caliano G; Magenes G
    Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():3223-3226. PubMed ID: 28268994
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Breast cancer detection using interferometric MUSIC: experimental and numerical assessment.
    Ruvio G; Solimene R; Cuccaro A; Gaetano D; Browne JE; Ammann MJ
    Med Phys; 2014 Oct; 41(10):103101. PubMed ID: 25281985
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.