These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 32566295)

  • 61. Clinical course of peritonitis due to Pseudomonas species complicating peritoneal dialysis: a review of 104 cases.
    Szeto CC; Chow KM; Leung CB; Wong TY; Wu AK; Wang AY; Lui SF; Li PK
    Kidney Int; 2001 Jun; 59(6):2309-15. PubMed ID: 11380835
    [TBL] [Abstract][Full Text] [Related]  

  • 62. Catheter type, placement and insertion techniques for preventing catheter-related infections in chronic peritoneal dialysis patients.
    Htay H; Johnson DW; Craig JC; Schena FP; Strippoli GF; Tong A; Cho Y
    Cochrane Database Syst Rev; 2019 May; 5(5):CD004680. PubMed ID: 31149735
    [TBL] [Abstract][Full Text] [Related]  

  • 63. Catheter-related complications during continuous ambulatory peritoneal dialysis (CAPD): a retrospective study on sixty-two double-cuff Tenckhoff catheters.
    Vogt K; Binswanger U; Buchmann P; Baumgartner D; Keusch G; Largiadèr F
    Am J Kidney Dis; 1987 Jul; 10(1):47-51. PubMed ID: 3605083
    [TBL] [Abstract][Full Text] [Related]  

  • 64. The impact of interventional nephrologists on the growth of a peritoneal dialysis program: Long-term, single-center experience.
    Ros-Ruiz S; Alonso-Esteve Á; Gutiérrez-Vílchez E; Rudas-Bermúdez E; Hernández D
    Nefrologia; 2016; 36(1):19-23. PubMed ID: 26520209
    [TBL] [Abstract][Full Text] [Related]  

  • 65. Delayed complications following Tenckhoff catheter removal.
    Elkabir JJ; Riaz AA; Agarwal SK; Williams G
    Nephrol Dial Transplant; 1999 Jun; 14(6):1550-2. PubMed ID: 10383023
    [TBL] [Abstract][Full Text] [Related]  

  • 66. Clinical outcomes of immediate full-volume exchange one year after peritoneal catheter implantation for CAPD.
    Song JH; Kim GA; Lee SW; Kim MJ
    Perit Dial Int; 2000; 20(2):194-9. PubMed ID: 10809243
    [TBL] [Abstract][Full Text] [Related]  

  • 67. Seldinger technique for Tenckhoff catheter placement.
    Zappacosta AR; Perras ST; Closkey GM
    ASAIO Trans; 1991; 37(1):13-5. PubMed ID: 2012711
    [TBL] [Abstract][Full Text] [Related]  

  • 68. Outcome of immediate use of the permanent peritoneal dialysis catheter in children with acute and chronic renal failure.
    Nikibakhsh AA; Mahmoodzadeh H; Vali M; Enashaei A; Asem A; Yekta Z
    Iran J Pediatr; 2013 Apr; 23(2):171-6. PubMed ID: 23724178
    [TBL] [Abstract][Full Text] [Related]  

  • 69. Our long-term results of Tenckhoff peritoneal dialysis catheters placement via laparoscopic preperitoneal tunneling technique.
    Gultekin FA; Cakmak GK; Karakaya K; Emre AU; Tascilar O; Oner MO; Comert M; Kulah E
    Semin Dial; 2013; 26(3):349-54. PubMed ID: 23013518
    [TBL] [Abstract][Full Text] [Related]  

  • 70. A half-percutaneous technique for peritoneal dialysis catheter implantation using a modified trocar: a report of 84 cases.
    Peng Y; Zhang D; Zheng T; Liu H; Su J; Xu Y; Hu X; Wu J; Chen G; Hou H; Ma S; Li Z; Zhu B; Lu F
    Int Urol Nephrol; 2019 Aug; 51(8):1451-1457. PubMed ID: 31119517
    [TBL] [Abstract][Full Text] [Related]  

  • 71. [Experiences with Tenckhoff peritoneal dialysis catheter].
    Regoczi T; Jósvay J; Bálint A; Csaba J; Rákossy W; Fodor E; Kiss I
    Orv Hetil; 2009 Nov; 150(46):2110-4. PubMed ID: 19889598
    [TBL] [Abstract][Full Text] [Related]  

  • 72. Use of fluoroscopy-guided wire manipulation and/or laparoscopic surgery in the repair of malfunctioning peritoneal dialysis catheters.
    Kim HJ; Lee TW; Ihm CG; Kim MJ
    Am J Nephrol; 2002; 22(5-6):532-8. PubMed ID: 12381955
    [TBL] [Abstract][Full Text] [Related]  

  • 73. Nephrologist-Initiated Peritoneal Dialysis Catheter Insertion Programme: A New Paradigm Shift.
    Goh BL
    Contrib Nephrol; 2017; 189():79-84. PubMed ID: 27951553
    [TBL] [Abstract][Full Text] [Related]  

  • 74. The use of TWH catheters in CAPD patients: fourteen-year experience in technique, survival, and complication rates.
    Apostolidis NS; Panoussopoulos DG; Manouras AJ; Pararas BN; Voudiklari SG; Zirogiannis PN
    Perit Dial Int; 1998; 18(4):424-8. PubMed ID: 10505566
    [TBL] [Abstract][Full Text] [Related]  

  • 75. Continuous ambulatory peritoneal dialysis catheter insertion by open technique: 20-year experience from a single center.
    Pahwa M; Singh M; Tyagi V; Gupta M; Jain S; Chaddha S; Jauhari H
    Indian J Urol; 2023; 39(1):46-52. PubMed ID: 36824120
    [TBL] [Abstract][Full Text] [Related]  

  • 76. The effects of peritoneal dialysis catheter insertion using paramedian versus midline approach on CAPD patients.
    Kanokkantapong C; Leeaphorn N; Kanjanabuch T
    J Med Assoc Thai; 2011 Sep; 94 Suppl 4():S52-7. PubMed ID: 22043567
    [TBL] [Abstract][Full Text] [Related]  

  • 77. Laparoscopic Tenckhoff catheter insertion: a prospective study of a new technique.
    Poole GH; Tervit P
    Aust N Z J Surg; 2000 May; 70(5):371-3. PubMed ID: 10830603
    [TBL] [Abstract][Full Text] [Related]  

  • 78. Peritoneal dialysis access: prospective randomized comparison of the Swan neck and Tenckhoff catheters.
    Eklund BH; Honkanen EO; Kala AR; Kyllönen LE
    Perit Dial Int; 1995; 15(8):353-6. PubMed ID: 8785234
    [TBL] [Abstract][Full Text] [Related]  

  • 79. Mini-laparoscopic placement of a peritoneal dialysis catheter.
    Varela JE; Elli EF; Vanuno D; Horgan S
    Surg Endosc; 2003 Dec; 17(12):2025-7. PubMed ID: 14973749
    [TBL] [Abstract][Full Text] [Related]  

  • 80. T-fluted peritoneal dialysis catheter.
    Ash SR; Janle EM
    Adv Perit Dial; 1993; 9():223-6. PubMed ID: 8105929
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.