BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

152 related articles for article (PubMed ID: 32567288)

  • 1. Direct left ventricular wire pacing during transcatheter aortic valve implantation.
    Stąpór M; Trębacz J; Wiewiórka Ł; Ostrowska-Kaim E; Nawara-Skipirzepa J; Sobczyński R; Konstanty-Kalandyk J; Musiał R; Trębacz O; Kleczyński P; Żmudka K; Kapelak B; Legutko J
    Kardiol Pol; 2020 Sep; 78(9):882-888. PubMed ID: 32567288
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Left Ventricular Rapid Pacing Via the Valve Delivery Guidewire in Transcatheter Aortic Valve Replacement.
    Faurie B; Souteyrand G; Staat P; Godin M; Caussin C; Van Belle E; Mangin L; Meyer P; Dumonteil N; Abdellaoui M; Monségu J; Durand-Zaleski I; Lefèvre T;
    JACC Cardiovasc Interv; 2019 Dec; 12(24):2449-2459. PubMed ID: 31857014
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Rapid pacing using the 0.035-in. Retrograde left ventricular support wire in 208 cases of transcatheter aortic valve implantation and balloon aortic valvuloplasty.
    Hilling-Smith R; Cockburn J; Dooley M; Parker J; Newton A; Hill A; Trivedi U; de Belder A; Hildick-Smith D
    Catheter Cardiovasc Interv; 2017 Mar; 89(4):783-786. PubMed ID: 27726292
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of left ventricular with right ventricular rapid pacing on tamponade during TAVI.
    Savvoulidis P; Mechery A; Lawton E; Ludman PF; Sharma H; Thompson S; Khalil A; Kalogeropoulos A; Q Khan S; Nadir A; Doshi SN
    Int J Cardiol; 2022 Aug; 360():46-52. PubMed ID: 35597495
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of left ventricular pacing performance among pre-shaped guidewires designed for transfemoral-approach transcatheter aortic valve implantation.
    Tamura Y; Tamura Y; Konami Y; Suzuyama H; Horio E; Yamada M; Sassa T; Taguchi E; Horibata Y; Ideta I; Kawamura A; Sakamoto T
    Heart Vessels; 2022 Mar; 37(3):460-466. PubMed ID: 34524498
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Direct transfemoral transcatheter aortic valve implantation without balloon pre-dilatation using the Edwards Sapien XT valve.
    Bandali A; Parry-Williams G; Kassam A; Palmer S; Williams PD; de Belder MA; Owens A; Goodwin A; Muir DF
    Catheter Cardiovasc Interv; 2016 Nov; 88(6):978-985. PubMed ID: 27189391
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Insights in a restricted temporary pacemaker strategy in a lean transcatheter aortic valve implantation program.
    Hokken TW; de Ronde M; Wolff Q; Schermers T; Ooms JF; van Wiechen MP; Kardys I; Daemen J; de Jaegere PP; Van Mieghem NM
    Catheter Cardiovasc Interv; 2022 Mar; 99(4):1197-1205. PubMed ID: 34837467
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Rapid pacing using the left ventricular guidewire: Reviving an old technique to simplify BAV and TAVI procedures.
    Faurie B; Abdellaoui M; Wautot F; Staat P; Champagnac D; Wintzer-Wehekind J; Vanzetto G; Bertrand B; Monségu J
    Catheter Cardiovasc Interv; 2016 Nov; 88(6):988-993. PubMed ID: 27510946
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Safety and Efficacy of TAVR With a Pressure Sensor and Pacing Guidewire: SAFE-TAVI Trial.
    Regueiro A; Alperi A; Vilalta V; Asmarats L; Baz JA; Nombela-Franco L; Calabuig A; Muñoz-García A; Sabaté M; Moris C; Picard-Deland M; Pelletier-Beaumont E; Rodés-Cabau J
    JACC Cardiovasc Interv; 2023 Dec; 16(24):3016-3023. PubMed ID: 37902144
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Transcatheter aortic valve implantation without prior balloon valvuloplasty is associated with less pronounced markers of myocardial injury.
    Mirna M; Wernly B; Eder S; Lichtenauer M; Prinz E; Wintersteller W; Jung C; Hoppe U; Hammerer M
    J Cardiovasc Surg (Torino); 2020 Apr; 61(2):243-249. PubMed ID: 30303343
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Risk factors for permanent pacemaker implantation in patients receiving a balloon-expandable transcatheter aortic valve prosthesis.
    Droppa M; Rudolph TK; Baan J; Nielsen NE; Baumgartner H; Vendrik J; Froehlich M; Borst O; Wöhrle J; Gawaz M; Potratz P; Hack LP; Mauri V; Baranowski J; Bramlage P; Kurucova J; Thoenes M; Rottbauer W; Geisler T
    Heart Vessels; 2020 Dec; 35(12):1735-1745. PubMed ID: 32591894
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Single-center prospective study examining use of the Wattson temporary pacing guidewire for transcatheter aortic valve replacement.
    Hensey M; Sathananthan J; Alkhodair A; Landes U; Wood DA; Daniels D; Webb JG
    Catheter Cardiovasc Interv; 2020 Oct; 96(4):968-971. PubMed ID: 32150334
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Balloon-expandable transaortic transcatheter aortic valve implantation with or without predilation.
    Bonaros N; Kofler M; Frank D; Cocchieri R; Jagielak D; Aiello M; Lapeze J; Laine M; Chocron S; Muir D; Eichinger W; Thielmann M; Labrousse L; Bapat V; Rein KA; Verhoye JP; Gerosa G; Baumbach H; Deutsch C; Bramlage P; Thoenes M; Romano M
    J Thorac Cardiovasc Surg; 2018 Mar; 155(3):915-923. PubMed ID: 29221741
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Prior Balloon Valvuloplasty Versus Direct Transcatheter Aortic Valve Replacement: Results From the DIRECTAVI Trial.
    Leclercq F; Robert P; Akodad M; Macia JC; Gandet T; Delseny D; Chettouh M; Schmutz L; Robert G; Levy G; Targosz F; Maupas E; Roubille F; Marin G; Nagot N; Albat B; Lattuca B; Cayla G
    JACC Cardiovasc Interv; 2020 Mar; 13(5):594-602. PubMed ID: 32139216
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Balloon-Expandable Transcatheter Aortic Valves Can Be Successfully and Safely Implanted Transfemorally Without Balloon Valvuloplasty.
    Aggarwal SK; Delahunty N; Wong B; Tamimi AN; Reinthaler M; Cheang MH; Roberts N; Yap J; Ozkor M; Mullen MJ
    J Interv Cardiol; 2016 Jun; 29(3):319-24. PubMed ID: 27245126
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Long-Term Outcomes in Patients With New Permanent Pacemaker Implantation Following Transcatheter Aortic Valve Replacement.
    Chamandi C; Barbanti M; Munoz-Garcia A; Latib A; Nombela-Franco L; Gutiérrez-Ibanez E; Veiga-Fernandez G; Cheema AN; Cruz-Gonzalez I; Serra V; Tamburino C; Mangieri A; Colombo A; Jiménez-Quevedo P; Elizaga J; Laughlin G; Lee DH; Garcia Del Blanco B; Rodriguez-Gabella T; Marsal JR; Côté M; Philippon F; Rodés-Cabau J
    JACC Cardiovasc Interv; 2018 Feb; 11(3):301-310. PubMed ID: 29413244
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Predictors of right ventricular pacing and pacemaker dependence in transcatheter aortic valve replacement patients.
    Sharma E; Chu AF
    J Interv Card Electrophysiol; 2018 Jan; 51(1):77-86. PubMed ID: 29260369
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Reducing cardiac tamponade caused by temporary pacemaker perforation in transcatheter aortic valve replacement.
    Feldt K; Dalén M; Meduri CU; Kastengren M; Bager J; Hörnsten J; Omar A; Rück A; Saleh N; Linder R; Settergren M
    Int J Cardiol; 2023 Apr; 377():26-32. PubMed ID: 36640966
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The Wattson temporary pacing guidewire for transcatheter heart valve implantation.
    Carey J; Buckley A; O'Connor S; Hensey M
    Future Cardiol; 2022 Apr; 18(4):275-283. PubMed ID: 34875868
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Timing of Onset and Outcome of New Conduction Abnormalities Following Transcatheter Aortic Valve Implantation: Role of Balloon Aortic Valvuloplasty.
    Campelo-Parada F; Nombela-Franco L; Urena M; Regueiro A; Jiménez-Quevedo P; Del Trigo M; Chamandi C; Rodríguez-Gabella T; Auffret V; Abdul-Jawad Altisent O; DeLarochellière R; Paradis JM; Dumont E; Philippon F; Pérez-Castellano N; Puri R; Macaya C; Rodés-Cabau J
    Rev Esp Cardiol (Engl Ed); 2018 Mar; 71(3):162-169. PubMed ID: 28566243
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.