These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 3256740)

  • 1. Self-calibrating interference refractometer using a linear photodiode array for anaesthetic gas analysis.
    Jackson RK; Palayiwa E; Sugg BR; Hahn CE; Weller S; Davies WL
    Med Biol Eng Comput; 1988 Sep; 26(5):516-22. PubMed ID: 3256740
    [No Abstract]   [Full Text] [Related]  

  • 2. Refractive indices for volatile anesthetic gases: equipment and method for calibrating vaporizers and monitors.
    Wallroth CF; Gippert KL; Ryschka M; Falb W; Hattendorff HD; Schramm B; Torge R; Mahrt KH; Kroebel W; Westenskow D
    J Clin Monit; 1995 May; 11(3):168-74. PubMed ID: 7623056
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Accuracy of the Datex Normac anaesthetic vapour analyser.
    Synnott A; Wren WS
    Anaesthesia; 1986 Mar; 41(3):322. PubMed ID: 3963338
    [No Abstract]   [Full Text] [Related]  

  • 4. An automated interferometer for the analysis of anesthetic gas mixtures.
    Palayiwa E
    Biomed Instrum Technol; 1989; 23(6):489-93. PubMed ID: 2590764
    [No Abstract]   [Full Text] [Related]  

  • 5. The use of a portable refractometer to measure desflurane.
    Cheam EW; Lockwood GG
    Anaesthesia; 1995 Jul; 50(7):607-10. PubMed ID: 7653759
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An automatic interference refractometer.
    Diprose KV; Redman LR
    Br J Anaesth; 1978 Nov; 50(11):1155-8. PubMed ID: 718786
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A new concept for the continuous monitoring of anesthetic gases. I. Detector theory and clinical uses.
    Gelb EJ; Steen SN
    Anesthesiology; 1970 Oct; 33(4):446-8. PubMed ID: 5512333
    [No Abstract]   [Full Text] [Related]  

  • 8. An automated interferometer for the analysis of anaesthetic gas mixtures.
    Sugg BR; Palayiwa E; Davies WL; Jackson R; McGraghan T; Shadbolt P; Weller SJ; Hahn CE
    Br J Anaesth; 1988 Oct; 61(4):484-91. PubMed ID: 3190975
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Monitoring for trace anesthetic gases in a veterinary teaching hospital.
    Dreesen DW; Jones GL; Brown J; Rawlings CA
    J Am Vet Med Assoc; 1981 Oct; 179(8):797-9. PubMed ID: 6896201
    [No Abstract]   [Full Text] [Related]  

  • 10. Anaesthetic gas monitoring comparison between two side-stream monitors.
    Heijbel H; Ostblom J; Brattwall M; Jakobsson J
    J Clin Monit Comput; 2010 Apr; 24(2):169-72. PubMed ID: 20238153
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An evaluation of the BrĂ¼el and Kjaer monitor 1304.
    McPeak HB; Palayiwa E; Robinson GC; Sykes MK
    Anaesthesia; 1992 Jan; 47(1):41-7. PubMed ID: 1536404
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of the Datex 'Normac' anaesthetic agent monitor.
    Luff NP; White DC
    Anaesthesia; 1985 Jun; 40(6):555-9. PubMed ID: 4025750
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Anaesthetic gas analysers for vaporiser calibration, patient circuit monitoring and determination of environmental waste anaesthetic gas levels.
    Ilsley AH; Plummer JL; Runciman WB; Cousins MJ
    Anaesth Intensive Care; 1988 Feb; 16(1):35-7. PubMed ID: 3364689
    [No Abstract]   [Full Text] [Related]  

  • 14. A static calibration method for the gas chromatographic determination of per cent concentrations of volatile anaesthetic agents.
    Gray WM
    Br J Anaesth; 1986 Mar; 58(3):345-52. PubMed ID: 3947498
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A laboratory investigation of a multigas monitor for anaesthesia (EMMA).
    Kay B; Cohen AT; Wheeler MF
    Anaesthesia; 1982 Apr; 37(4):446-50. PubMed ID: 7081689
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The "narkotest" anaesthetic gas meter.
    White DC; Wardley-Smith B
    Br J Anaesth; 1972 Oct; 44(10):1100-4. PubMed ID: 4674285
    [No Abstract]   [Full Text] [Related]  

  • 17. Automated interference refractometer: an algorithm for locating an irregular fringe pattern.
    Jeavons PG
    J Biomed Eng; 1987 Apr; 9(2):157-60. PubMed ID: 3573756
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The ejector flowmeter: an evaluation of its accuracy.
    Waaben J; Thomsen A
    Acta Anaesthesiol Scand; 1978; 22(5):527-9. PubMed ID: 151475
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Calibration atmosphere generator for operating theatre pollution studies. A system for the controlled production of trace concentrations of inhalation anaesthetics.
    Gray WM; Burnside GW
    Br J Anaesth; 1984 May; 56(5):543-50. PubMed ID: 6721963
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Studies on the calibration of enflurane vaporizers.
    Dobkin AB; Kim D; Levy AA; Byles PH
    Anesth Analg; 1973; 52(3):317-21. PubMed ID: 4735982
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.