110 related articles for article (PubMed ID: 3256742)

  • 1. Mathematical simulation of an amperometric enzyme-substrate electrode with a pO2 basic sensor. Part 2. Mathematical simulation of the glucose oxidase glucose electrode.
    Lemke K
    Med Biol Eng Comput; 1988 Sep; 26(5):533-40. PubMed ID: 3256742
    [No Abstract]   [Full Text] [Related]  

  • 2. Mathematical stimulation of an amperometric enzyme-substrate electrode with a pO2 basic sensor. Part 1. Mathematical model and simulation of the pO2 basic sensor.
    Lemke K
    Med Biol Eng Comput; 1988 Sep; 26(5):523-32. PubMed ID: 3256741
    [No Abstract]   [Full Text] [Related]  

  • 3. Mathematical simulation of an enzyme-based glucose sensor with pO2-basic sensor.
    Lemke K
    Biomed Biochim Acta; 1989; 48(11-12):867-77. PubMed ID: 2636831
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Two-dimensional enzyme electrode sensor for glucose.
    Gough DA; Lucisano JY; Tse PH
    Anal Chem; 1985 Oct; 57(12):2351-7. PubMed ID: 4061843
    [No Abstract]   [Full Text] [Related]  

  • 5. Transient response of bienzyme electrodes.
    Kulys JJ; Sorochinskii VV; Vidziunaite RA
    Biosensors; 1986; 2(3):135-46. PubMed ID: 3814190
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A comparison between different immobilised glucoseoxidase-based electrodes.
    Memoli A; Annesini MC; Mascini M; Papale S; Petralito S
    J Pharm Biomed Anal; 2002 Aug; 29(6):1045-52. PubMed ID: 12110389
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Magnetic enzyme membranes as active elements of electrochemical sensors. Lactose, saccharose, maltose bienzyme electrodes.
    Cordonnier M; Lawny F; Chapot D; Thomas D
    FEBS Lett; 1975 Nov; 59(2):263-7. PubMed ID: 1227943
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Amperometric glucose biosensor based on adsorption of glucose oxidase at platinum nanoparticle-modified carbon nanotube electrode.
    Tang H; Chen J; Yao S; Nie L; Deng G; Kuang Y
    Anal Biochem; 2004 Aug; 331(1):89-97. PubMed ID: 15246000
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Highly selective amperometric glucose microdevice derived from diffusion layer gap electrode.
    Jia WZ; Hu YL; Song YY; Wang K; Xia XH
    Biosens Bioelectron; 2008 Jan; 23(6):892-8. PubMed ID: 18029169
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Initial studies of a new approach to the design and use of enzyme-based reactor/sensor systems: amperometric system for glucose.
    Uhegbu CE; Lim KB; Pardue HL
    Anal Chem; 1993 Sep; 65(18):2443-51. PubMed ID: 8238938
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Model-based optimization of a conductive matrix enzyme electrode.
    Wu X; Detzel CJ; Van Wie BJ; Haarsma SJ; Kidwell DA
    Biotechnol Bioeng; 2004 Oct; 88(2):204-13. PubMed ID: 15449294
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Preparation and validation of implantable electrodes for the measurement of oxygen and glucose.
    Brunstein E; Abel P; Gens A; Eich K; Woedtke TV
    Biomed Biochim Acta; 1989; 48(11-12):911-7. PubMed ID: 2636836
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [A flow-through method for the O2-sensitive, enzymatic analysis of glucose (author's transl)].
    Schindler JG; Riemann W; Sailer D; Berg G
    J Clin Chem Clin Biochem; 1977 Dec; 15(12):709-13. PubMed ID: 604423
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A glucose sensor utilising tetracyanoquinodimethane as a mediator.
    Hendry SP; Turner AP
    Horm Metab Res Suppl; 1988; 20():37-40. PubMed ID: 3248789
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Glucose-oxidase electrode. Measurements of glucose in samples exhibiting high variability in oxygen content.
    Romette JL; Froment B; Thomas D
    Clin Chim Acta; 1979 Jul; 95(2):249-53. PubMed ID: 527223
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A multilayer membrane amperometric glucose sensor fabricated using planar techniques for large-scale production.
    Matsumoto T; Saito S; Ikeda S
    J Biotechnol; 2006 Mar; 122(2):267-73. PubMed ID: 16219381
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An amperometric glucose sensor with combined enzyme layers.
    Weiss T; Cammann K
    Horm Metab Res Suppl; 1988; 20():23-5. PubMed ID: 3248786
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A potentially implantable enzyme electrode for amperometric measurement of glucose.
    Kerner W; Zier H; Steinbach G; Brückel J; Pfeiffer EF; Weiss T; Cammann K; Planck H
    Horm Metab Res Suppl; 1988; 20():8-13. PubMed ID: 3248792
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Immobilized enzymes: a prototype apparatus for oxidase enzymes in chemical analysis utilizing covalently bound glucose oxidase.
    Weibel MK; Dritschilo W; Bright HJ; Humphrey AE
    Anal Biochem; 1973 Apr; 52(2):402-14. PubMed ID: 4349183
    [No Abstract]   [Full Text] [Related]  

  • 20. Amperometric glucose biosensor based on gold-deposited polyvinylferrocene film on Pt electrode.
    Topçu Sulak M; Gökdoğan O; Gülce A; Gülce H
    Biosens Bioelectron; 2006 Mar; 21(9):1719-26. PubMed ID: 16198102
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]