117 related articles for article (PubMed ID: 32569954)
1. Large-scale dosimetric assessment of Monte Carlo recalculated doses for lung robotic stereotactic body radiation therapy.
Heng VJ; Renaud MA; Zerouali K; Doucet R; Diamant A; Bahig H; DeBlois F; Seuntjens J
Phys Med; 2020 Aug; 76():7-15. PubMed ID: 32569954
[TBL] [Abstract][Full Text] [Related]
2. Assessment of Monte Carlo algorithm for compliance with RTOG 0915 dosimetric criteria in peripheral lung cancer patients treated with stereotactic body radiotherapy.
Pokhrel D; Sood S; Badkul R; Jiang H; McClinton C; Lominska C; Kumar P; Wang F
J Appl Clin Med Phys; 2016 May; 17(3):277-293. PubMed ID: 27167284
[TBL] [Abstract][Full Text] [Related]
3. Dosimetric verification using monte carlo calculations for tissue heterogeneity-corrected conformal treatment plans following RTOG 0813 dosimetric criteria for lung cancer stereotactic body radiotherapy.
Li J; Galvin J; Harrison A; Timmerman R; Yu Y; Xiao Y
Int J Radiat Oncol Biol Phys; 2012 Oct; 84(2):508-13. PubMed ID: 22365630
[TBL] [Abstract][Full Text] [Related]
4. Influence of CyberKnife Prescription Isodose Line on the Discrepancy of Dose Results Calculated by the Ray Tracing and Monte Carlo Algorithms for Head and Lung Plans: A Phantom Study.
Yang J; Liu G; Liu HY; Nie X; Yang ZY; Han J; Zhang S; Liang ZW
Curr Med Sci; 2020 Apr; 40(2):301-306. PubMed ID: 32337689
[TBL] [Abstract][Full Text] [Related]
5. Technical Note: Dosimetric evaluation of Monte Carlo algorithm in iPlan for stereotactic ablative body radiotherapy (SABR) for lung cancer patients using RTOG 0813 parameters.
Pokhrel D; Badkul R; Jiang H; Kumar P; Wang F
J Appl Clin Med Phys; 2015 Jan; 16(1):5058. PubMed ID: 25679161
[TBL] [Abstract][Full Text] [Related]
6. Dose calculation differences between Monte Carlo and pencil beam depend on the tumor locations and volumes for lung stereotactic body radiation therapy.
Zhuang T; Djemil T; Qi P; Magnelli A; Stephans K; Videtic G; Xia P
J Appl Clin Med Phys; 2013 Mar; 14(2):4011. PubMed ID: 23470930
[TBL] [Abstract][Full Text] [Related]
7. Effect of the normalized prescription isodose line on the magnitude of Monte Carlo vs. pencil beam target dose differences for lung stereotactic body radiotherapy.
Zheng D; Zhang Q; Liang X; Zhu X; Verma V; Wang S; Zhou S
J Appl Clin Med Phys; 2016 Jul; 17(4):48-58. PubMed ID: 27455476
[TBL] [Abstract][Full Text] [Related]
8. Dose differences in intensity-modulated radiotherapy plans calculated with pencil beam and Monte Carlo for lung SBRT.
Liu H; Zhuang T; Stephans K; Videtic G; Raithel S; Djemil T; Xia P
J Appl Clin Med Phys; 2015 Nov; 16(6):91–99. PubMed ID: 26699560
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of the influence of tumor location and size on the difference of dose calculation between Ray Tracing algorithm and Fast Monte Carlo algorithm in stereotactic body radiotherapy of non-small cell lung cancer using CyberKnife.
Wu VW; Tam KW; Tong SM
J Appl Clin Med Phys; 2013 Sep; 14(5):68-78. PubMed ID: 24036860
[TBL] [Abstract][Full Text] [Related]
10. On the use of a convolution-superposition algorithm for plan checking in lung stereotactic body radiation therapy.
Hardcastle N; Oborn BM; Haworth A
J Appl Clin Med Phys; 2016 Sep; 17(5):99-110. PubMed ID: 27685114
[TBL] [Abstract][Full Text] [Related]
11. Comparison of Ray Tracing and Monte Carlo Calculation Algorithms for Thoracic Spine Lesions Treated With CyberKnife-Based Stereotactic Body Radiation Therapy.
Okoye CC; Patel RB; Hasan S; Podder T; Khouri A; Fabien J; Zhang Y; Dobbins D; Sohn JW; Yuan J; Yao M; Machtay M; Sloan AE; Miller J; Lo SS
Technol Cancer Res Treat; 2016 Feb; 15(1):196-202. PubMed ID: 25633137
[TBL] [Abstract][Full Text] [Related]
12. Investigation of four-dimensional (4D) Monte Carlo dose calculation in real-time tumor tracking stereotatic body radiotherapy for lung cancers.
Chan MK; Kwong DL; Ng SC; Tam EK; Tong AS
Med Phys; 2012 Sep; 39(9):5479-87. PubMed ID: 22957615
[TBL] [Abstract][Full Text] [Related]
13. Dosimetric errors during treatment of centrally located lung tumors with stereotactic body radiation therapy: Monte Carlo evaluation of tissue inhomogeneity corrections.
Altunbas C; Kavanagh B; Dzingle W; Stuhr K; Gaspar L; Miften M
Med Dosim; 2013; 38(4):436-41. PubMed ID: 24119416
[TBL] [Abstract][Full Text] [Related]
14. A modified formula for dose calculations of stereotactic ablative body radiotherapy for non-small cell lung cancer.
Cao Y; Zhu X; Zhang Y; Yu C; Liu Y; Sun Y; Dai Z; Guo X; Ju X; Zhang H
Med Dosim; 2018 Autumn; 43(3):207-213. PubMed ID: 28993019
[TBL] [Abstract][Full Text] [Related]
15. Dosimetric differences between local failure and local controlled non-small cell lung cancer patients treated with stereotactic body radiotherapy: A matched-pair study.
Zhuang T; Woody NM; Liu H; Cherian S; Reddy CA; Qi P; Magnelli A; Djemil T; Stephans KL; Xia P; Videtic GM
J Med Imaging Radiat Oncol; 2018 Jun; 62(3):420-424. PubMed ID: 29399972
[TBL] [Abstract][Full Text] [Related]
16. Retrospective monte carlo dose calculations with limited beam weight information.
Lindsay PE; El Naqa I; Hope AJ; Vicic M; Cui J; Bradley JD; Deasy JO
Med Phys; 2007 Jan; 34(1):334-46. PubMed ID: 17278519
[TBL] [Abstract][Full Text] [Related]
17. Adapted Prescription Dose for Monte Carlo Algorithm in Lung SBRT: Clinical Outcome on 205 Patients.
Bibault JE; Mirabel X; Lacornerie T; Tresch E; Reynaert N; Lartigau E
PLoS One; 2015; 10(7):e0133617. PubMed ID: 26207808
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of newly implemented dose calculation algorithms for multileaf collimator-based CyberKnife tumor-tracking radiotherapy.
Kawata K; Kamomae T; Oguchi H; Kawabata F; Okudaira K; Kawamura M; Ohtakara K; Itoh Y; Naganawa S
Med Phys; 2020 Mar; 47(3):1391-1403. PubMed ID: 31913508
[TBL] [Abstract][Full Text] [Related]
19. Combination effects of tissue heterogeneity and geometric targeting error in stereotactic body radiotherapy for lung cancer using CyberKnife.
Kang KM; Jeong BK; Choi HS; Yoo SH; Hwang UJ; Lim YK; Jeong H
J Appl Clin Med Phys; 2015 Sep; 16(5):193-204. PubMed ID: 26699300
[TBL] [Abstract][Full Text] [Related]
20. Clinical verification of treatment planning dose calculation in lung SBRT with GATE Monte Carlo simulation code.
Ruiz Boiset G; V S Batista D; Coutinho Cardoso S
Phys Med; 2021 Jul; 87():1-10. PubMed ID: 34091196
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]