These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

223 related articles for article (PubMed ID: 32570942)

  • 1. Layered Double Hydroxide-Modified Organic Electrochemical Transistor for Glucose and Lactate Biosensing.
    Gualandi I; Tessarolo M; Mariani F; Arcangeli D; Possanzini L; Tonelli D; Fraboni B; Scavetta E
    Sensors (Basel); 2020 Jun; 20(12):. PubMed ID: 32570942
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Highly Sensitive Glucose Sensor Based on Organic Electrochemical Transistor with Modified Gate Electrode.
    Ji X; Chan PK
    Methods Mol Biol; 2017; 1572():205-216. PubMed ID: 28299690
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A novel glucose sensor based on monodispersed Ni/Al layered double hydroxide and chitosan.
    Ai H; Huang X; Zhu Z; Liu J; Chi Q; Li Y; Li Z; Ji X
    Biosens Bioelectron; 2008 Dec; 24(4):1054-8. PubMed ID: 18782662
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Diamond nanoparticles based biosensors for efficient glucose and lactate determination.
    Briones M; Casero E; Petit-Domínguez MD; Ruiz MA; Parra-Alfambra AM; Pariente F; Lorenzo E; Vázquez L
    Biosens Bioelectron; 2015 Jun; 68():521-528. PubMed ID: 25636025
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Highly sensitive dopamine biosensors based on organic electrochemical transistors.
    Tang H; Lin P; Chan HL; Yan F
    Biosens Bioelectron; 2011 Jul; 26(11):4559-63. PubMed ID: 21652201
    [TBL] [Abstract][Full Text] [Related]  

  • 6. AC Electrodeposition of PEDOT Films in Protic Ionic Liquids for Long-Term Stable Organic Electrochemical Transistors.
    Ji J; Zhu X; Han D; Li M; Zhang Q; Shu Y; Cheng Z; Zhang W; Hua E; Sang S
    Molecules; 2019 Nov; 24(22):. PubMed ID: 31739407
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Processable enzyme-hybrid conductive polymer composites for electrochemical biosensing.
    Liu Y; Turner APF; Zhao M; Mak WC
    Biosens Bioelectron; 2018 Feb; 100():374-381. PubMed ID: 28946109
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A highly sensitive molecular structural probe applied to in situ biosensing of metabolites using PEDOT:PSS.
    Tan E; Pappa AM; Pitsalidis C; Nightingale J; Wood S; Castro FA; Owens RM; Kim JS
    Biotechnol Bioeng; 2020 Jan; 117(1):291-299. PubMed ID: 31589342
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Thin-film amperometric multibiosensor for simultaneous determination of lactate and glucose in wine.
    Shkotova LV; Piechniakova NY; Kukla OL; Dzyadevych SV
    Food Chem; 2016 Apr; 197(Pt A):972-8. PubMed ID: 26617042
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Enhancing biosensor properties of conducting polymers via copolymerization: Synthesis of EDOT-substituted bis(2-pyridylimino)isoindolato-palladium complex and electrochemical sensing of glucose by its copolymerized film.
    Tekbaşoğlu TY; Soganci T; Ak M; Koca A; Şener MK
    Biosens Bioelectron; 2017 Jan; 87():81-88. PubMed ID: 27522481
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Novel amperometric glucose biosensor based on MXene nanocomposite.
    Rakhi RB; Nayak P; Xia C; Alshareef HN
    Sci Rep; 2016 Nov; 6():36422. PubMed ID: 27830757
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A highly selective amperometric biosensor array for the simultaneous determination of glutamate, glucose, choline, acetylcholine, lactate and pyruvate.
    Kucherenko DY; Kucherenko IS; Soldatkin OO; Topolnikova YV; Dzyadevych SV; Soldatkin AP
    Bioelectrochemistry; 2019 Aug; 128():100-108. PubMed ID: 30959397
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fabrication of organic electrochemical transistor arrays for biosensing.
    Zhang M; Lin P; Yang M; Yan F
    Biochim Biophys Acta; 2013 Sep; 1830(9):4402-6. PubMed ID: 22981912
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Amperometric enzyme electrodes of glucose and lactate based on poly(diallyldimethylammonium)-alginate-metal ion-enzyme biocomposites.
    Qin C; Chen C; Xie Q; Wang L; He X; Huang Y; Zhou Y; Xie F; Yang D; Yao S
    Anal Chim Acta; 2012 Mar; 720():49-56. PubMed ID: 22365120
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Electrochemical study of ferrocenemethanol-modified layered double hydroxides composite matrix: application to glucose amperometric biosensor.
    Shan D; Yao W; Xue H
    Biosens Bioelectron; 2007 Oct; 23(3):432-7. PubMed ID: 17720475
    [TBL] [Abstract][Full Text] [Related]  

  • 16. All-plastic electrochemical transistor for glucose sensing using a ferrocene mediator.
    Shim NY; Bernards DA; Macaya DJ; Defranco JA; Nikolou M; Owens RM; Malliaras GG
    Sensors (Basel); 2009; 9(12):9896-902. PubMed ID: 22303153
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Concentric-Electrode Organic Electrochemical Transistors: Case Study for Selective Hydrazine Sensing.
    Pecqueur S; Lenfant S; Guérin D; Alibart F; Vuillaume D
    Sensors (Basel); 2017 Mar; 17(3):. PubMed ID: 28287475
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Bioelectrocatalysis and surface analysis of gold coated with nickel oxide/hydroxide and glucose oxidase towards detection of glucose.
    Njoko N; Louzada M; Britton J; Khene S; Nyokong T; Mashazi P
    Colloids Surf B Biointerfaces; 2020 Jun; 190():110981. PubMed ID: 32200212
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Unsubstituted phenothiazine as a superior water-insoluble mediator for oxidases.
    Sekretaryova AN; Vagin MY; Beni V; Turner AP; Karyakin AA
    Biosens Bioelectron; 2014 Mar; 53():275-82. PubMed ID: 24144558
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biocompatible Ionic Liquids in High-Performing Organic Electrochemical Transistors for Ion Detection and Electrophysiological Monitoring.
    Li T; Cheryl Koh JY; Moudgil A; Cao H; Wu X; Chen S; Hou K; Surendran A; Stephen M; Tang C; Wang C; Wang QJ; Tay CY; Leong WL
    ACS Nano; 2022 Aug; 16(8):12049-12060. PubMed ID: 35939084
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.