168 related articles for article (PubMed ID: 32573027)
1. Strict selection criteria in uncontrolled donation after circulatory death provide excellent long-term kidney graft survival.
Miñambres E; Rodrigo E; Suberviola B; Valero R; Quintana A; Campos F; Ruiz-San Millán JC; Ballesteros MÁ
Clin Transplant; 2020 Sep; 34(9):e14010. PubMed ID: 32573027
[TBL] [Abstract][Full Text] [Related]
2. Kidney transplant from uncontrolled donation after circulatory death donors maintained by nECMO has long-term outcomes comparable to standard criteria donation after brain death.
Molina M; Guerrero-Ramos F; Fernández-Ruiz M; González E; Cabrera J; Morales E; Gutierrez E; Hernández E; Polanco N; Hernández A; Praga M; Rodriguez-Antolín A; Pamplona M; de la Rosa F; Cavero T; Chico M; Villar A; Justo I; Andrés A
Am J Transplant; 2019 Feb; 19(2):434-447. PubMed ID: 29947163
[TBL] [Abstract][Full Text] [Related]
3. Transplantation of kidneys from uncontrolled donation after circulatory determination of death: comparison with brain death donors with or without extended criteria and impact of normothermic regional perfusion.
Demiselle J; Augusto JF; Videcoq M; Legeard E; Dubé L; Templier F; Renaudin K; Sayegh J; Karam G; Blancho G; Dantal J
Transpl Int; 2016 Apr; 29(4):432-42. PubMed ID: 26606511
[TBL] [Abstract][Full Text] [Related]
4. Uncontrolled donation after circulatory death: A cohort study of data from a long-standing deceased-donor kidney transplantation program.
Sánchez-Fructuoso AI; Pérez-Flores I; Del Río F; Blázquez J; Calvo N; Moreno de la Higuera MÁ; Gómez A; Alonso-Lera S; Soria A; González M; Corral E; Mateos A; Moreno-Sierra J; Fernández Pérez C
Am J Transplant; 2019 Jun; 19(6):1693-1707. PubMed ID: 30589507
[TBL] [Abstract][Full Text] [Related]
5. Similar 5-Year Estimated Glomerular Filtration Rate Between Kidney Transplants From Uncontrolled and Controlled Donors After Circulatory Death-A Dutch Cohort Study.
Peters-Sengers H; Homan van der Heide JJ; Heemskerk MBA; Ten Berge IJM; Ultee FCW; Idu MM; Betjes MGH; van Zuilen AD; Christiaans MHL; Hilbrands LH; de Vries APJ; Nurmohamed AS; Berger SP; Bemelman FJ
Transplantation; 2017 Jun; 101(6):1144-1151. PubMed ID: 27257998
[TBL] [Abstract][Full Text] [Related]
6. Kidney transplantation from donors after uncontrolled circulatory death: the Spanish experience.
Del Río F; Andrés A; Padilla M; Sánchez-Fructuoso AI; Molina M; Ruiz Á; Pérez-Villares JM; Peiró LZ; Aldabó T; Sebastián R; Miñambres E; Pita L; Casares M; Galán J; Vidal C; Terrón C; Castro P; Sanroma M; Coll E; Domínguez-Gil B;
Kidney Int; 2019 Feb; 95(2):420-428. PubMed ID: 30579725
[TBL] [Abstract][Full Text] [Related]
7. Kidney Transplantation Outcomes From Uncontrolled Donation After Circulatory Death: A Systematic Review and Meta-analysis.
Vijayan K; Schroder HJ; Hameed A; Hitos K; Lo W; Laurence JM; Yoon PD; Nahm C; Lim WH; Lee T; Yuen L; Wong G; Pleass H
Transplantation; 2024 Jun; 108(6):1422-1429. PubMed ID: 38361237
[TBL] [Abstract][Full Text] [Related]
8. Liver transplantation with uncontrolled versus controlled DCD donors using normothermic regional perfusion and ex-situ machine perfusion.
Ghinolfi D; Patrono D; De Carlis R; Melandro F; Buscemi V; Farnesi F; Torri F; Lauterio A; Di Salvo M; Cerchione R; Zanierato M; Morganti R; Romagnoli R; De Simone P; De Carlis L
Liver Transpl; 2024 Jan; 30(1):46-60. PubMed ID: 37450659
[TBL] [Abstract][Full Text] [Related]
9. Uncontrolled donation after cardiac death kidney transplantation: Opportunity to expand the donor pool?
Rouhi AD; Choudhury RA; Hoeltzel GD; Prins K; Yoeli D; Moore HB; Williams NN; Dumon KR; Nydam TL
Am J Surg; 2023 Jun; 225(6):1102-1107. PubMed ID: 36609078
[TBL] [Abstract][Full Text] [Related]
10. The development of a predictive model of graft function in uncontrolled donors after circulatory death: validity of a pulsatile renal preservation machine cut-off value for kidney acceptance.
Gelpi R; Paredes D; Rodríguez-Villar C; Roque R; Ruiz A; Adalia R; Peri-Cusí L; Sole M; Oppenheimer F; Diekmann F
Nephrol Dial Transplant; 2019 Mar; 34(3):531-538. PubMed ID: 30085267
[TBL] [Abstract][Full Text] [Related]
11. Rapid Access in Donation After Circulatory Death (DCD): The Single-Center Experience With a Classic Pathway in Uncontrolled DCD Algorithm.
Pabisiak K; Tejchman K; Ostrowski M; Ciechanowski K; Sieńko J
Transplant Proc; 2022 Apr; 54(3):595-599. PubMed ID: 35256196
[TBL] [Abstract][Full Text] [Related]
12. Kidney transplantation from donation after cardiac death donors: lack of impact of delayed graft function on post-transplant outcomes.
Singh RP; Farney AC; Rogers J; Zuckerman J; Reeves-Daniel A; Hartmann E; Iskandar S; Adams P; Stratta RJ
Clin Transplant; 2011; 25(2):255-64. PubMed ID: 20331689
[TBL] [Abstract][Full Text] [Related]
13. Implementation of donation after circulatory death kidney transplantation can safely enlarge the donor pool: A systematic review and meta-analysis.
Rijkse E; Ceuppens S; Qi H; IJzermans JNM; Hesselink DA; Minnee RC
Int J Surg; 2021 Aug; 92():106021. PubMed ID: 34256169
[TBL] [Abstract][Full Text] [Related]
14. Liver Transplantation Using Uncontrolled Donors After Circulatory Death: A 10-year Single-center Experience.
Jiménez-Romero C; Manrique A; Calvo J; Caso Ó; Marcacuzco A; García-Sesma Á; Abradelo M; Nutu A; García-Conde M; San Juan R; Justo I
Transplantation; 2019 Dec; 103(12):2497-2505. PubMed ID: 31765364
[TBL] [Abstract][Full Text] [Related]
15. Kidney transplantation following uncontrolled donation after circulatory death.
Summers DM; Pettigrew GJ
Curr Opin Organ Transplant; 2020 Apr; 25(2):144-150. PubMed ID: 32073483
[TBL] [Abstract][Full Text] [Related]
16. The impact of kidney donor profile index on delayed graft function and transplant outcomes: A single-center analysis.
Zens TJ; Danobeitia JS; Leverson G; Chlebeck PJ; Zitur LJ; Redfield RR; D'Alessandro AM; Odorico S; Kaufman DB; Fernandez LA
Clin Transplant; 2018 Mar; 32(3):e13190. PubMed ID: 29314286
[TBL] [Abstract][Full Text] [Related]
17. Uncontrolled donation after circulatory death: comparison of two kidney preservation protocols on graft outcomes.
Delsuc C; Faure A; Berthiller J; Dorez D; Matillon X; Meas-Yedid V; Floccard B; Marcotte G; Labeye V; Rabeyrin M; Codas R; Chauvet C; Robinson P; Morelon E; Badet L; Hanf W; Rimmelé T
BMC Nephrol; 2018 Jan; 19(1):3. PubMed ID: 29310591
[TBL] [Abstract][Full Text] [Related]
18. Hypothermic Machine Perfusion Results in a Marginal Kidney Transplant Programme.
Gómez-Dos Santos V; Ruiz Hernández M; Burgos-Revilla FJ
Eur Urol Focus; 2018 Mar; 4(2):163-168. PubMed ID: 29929872
[TBL] [Abstract][Full Text] [Related]
19. Successful Porcine Renal Transplantation After 60 Minutes of Donor Warm Ischemia: Extracorporeal Perfusion and Thrombolytics.
Demos DS; Iyengar A; Bryner BS; Gray BW; Hoffman HR; Cornell MS; Wilkinson JE; Mazur DE; Bartlett RH; Punch JD; Rojas-Peña A
ASAIO J; 2015; 61(4):474-9. PubMed ID: 25851315
[TBL] [Abstract][Full Text] [Related]
20. Comparison of outcomes of kidney transplantation from donation after brain death, donation after circulatory death, and donation after brain death followed by circulatory death donors.
Chen G; Wang C; Ko DS; Qiu J; Yuan X; Han M; Wang C; He X; Chen L
Clin Transplant; 2017 Nov; 31(11):. PubMed ID: 28886219
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]