141 related articles for article (PubMed ID: 32577607)
1. Accuracy of dynamic contour tonometry, Goldmann applanation tonometry, and Tono-Pen XL in edematous corneas. Kontadakis GA; Pennos A; Pentari I; Kymionis GD; Pallikaris IG; Ginis H Ther Adv Ophthalmol; 2020; 12():2515841420923190. PubMed ID: 32577607 [TBL] [Abstract][Full Text] [Related]
2. The impact of corneal edema on intraocular pressure measurements using goldmann applanation tonometry, Tono-Pen XL, iCare, and ORA: an in vitro model. Neuburger M; Maier P; Böhringer D; Reinhard T; F Jordan J J Glaucoma; 2013 Sep; 22(7):584-90. PubMed ID: 22366704 [TBL] [Abstract][Full Text] [Related]
3. Variations of Intraocular Pressure Measured by Goldmann Applanation Tonometer, Tono-Pen, iCare Rebound Tonometer, and Pascal Dynamic Contour Tonometer in Patients With Corneal Edema After Phacoemulsification. Kiddee W; Tanjana A J Glaucoma; 2021 Apr; 30(4):317-324. PubMed ID: 33137014 [TBL] [Abstract][Full Text] [Related]
4. Corneal modulus and IOP measurements in canine eyes using Goldmann applanation tonometry and Tono-pen. Tang J; Pan X; Weber PA; Liu J Invest Ophthalmol Vis Sci; 2011 Oct; 52(11):7866-71. PubMed ID: 21896862 [TBL] [Abstract][Full Text] [Related]
5. [Measurement of intraocular pressure using the Tono-Pen in comparison with Goldmann applanation tonometry - a clinical study in 100 eyes]. Deuter CM; Schlote T; Hahn GA; Bende T; Derse M Klin Monbl Augenheilkd; 2002 Mar; 219(3):138-42. PubMed ID: 11987041 [TBL] [Abstract][Full Text] [Related]
6. Effect of corneal stiffening on Goldmann applanation tonometry and Tono-Pen measurements in canine eyes. Tang J; Pan X; Weber PA; Liu J Invest Ophthalmol Vis Sci; 2012 Mar; 53(3):1397-405. PubMed ID: 22297494 [TBL] [Abstract][Full Text] [Related]
7. Clinical comparison of the ProTon and Tono-Pen tonometers with the Goldmann applanation tonometer. Midelfart A; Wigers A Br J Ophthalmol; 1994 Dec; 78(12):895-8. PubMed ID: 7819170 [TBL] [Abstract][Full Text] [Related]
8. Oculab Tono-Pen, Goldmann applanation tonometry, and pneumatic tonometry for intraocular pressure assessment in gas-filled eyes. Hines MW; Jost BF; Fogelman KL Am J Ophthalmol; 1988 Aug; 106(2):174-9. PubMed ID: 3400759 [TBL] [Abstract][Full Text] [Related]
9. The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry. Tonnu PA; Ho T; Newson T; El Sheikh A; Sharma K; White E; Bunce C; Garway-Heath D Br J Ophthalmol; 2005 Jul; 89(7):851-4. PubMed ID: 15965165 [TBL] [Abstract][Full Text] [Related]
10. Intraocular pressure measurement-comparison of dynamic contour tonometry and goldmann applanation tonometry. Schneider E; Grehn F J Glaucoma; 2006 Feb; 15(1):2-6. PubMed ID: 16378009 [TBL] [Abstract][Full Text] [Related]
11. Tono-Pen versus Goldmann Applanation Tonometry: A Comparison of 898 Eyes. Bao B; Diaconita V; Schulz DC; Hutnik C Ophthalmol Glaucoma; 2019; 2(6):435-439. PubMed ID: 32672578 [TBL] [Abstract][Full Text] [Related]
12. Correlation between Central Corneal Thickness and Intraocular Pressure Measured by Goldmann Applanation Tonometry or Pascal Dynamic Contour Tonometry. Katsimpris JM; Theoulakis PE; Vasilopoulos K; Skourtis G; Papadopoulos GE; Petropoulos IK Klin Monbl Augenheilkd; 2015 Apr; 232(4):414-8. PubMed ID: 25902089 [TBL] [Abstract][Full Text] [Related]
13. [Clinical comparison of the Tono-Pen tonometer to the Goldmann applanation tonometer]. Jiang B; Jiang Y Yan Ke Xue Bao; 2002 Dec; 18(4):226-9. PubMed ID: 15515766 [TBL] [Abstract][Full Text] [Related]
14. Intraocular Pressure Measurement after Penetrating Keratoplasty. Dumitrescu OM; Istrate S; Macovei ML; Gheorghe AG Diagnostics (Basel); 2022 Jan; 12(2):. PubMed ID: 35204325 [TBL] [Abstract][Full Text] [Related]
15. Tono-Pen tonometry in normal and in post-keratoplasty eyes. Geyer O; Mayron Y; Loewenstein A; Neudorfer M; Rothkoff L; Lazar M Br J Ophthalmol; 1992 Sep; 76(9):538-40. PubMed ID: 1420058 [TBL] [Abstract][Full Text] [Related]
16. Comparison of Scleral Tono-Pen Intraocular Pressure Measurements with Goldmann Applanation Tonometry. Badakere SV; Choudhari NS; Rao HL; Chary CR; Garudadri CS; Senthil S Optom Vis Sci; 2018 Feb; 95(2):129-135. PubMed ID: 29370020 [TBL] [Abstract][Full Text] [Related]
17. Goldmann tonometry versus the Tono-Pen XL for intraocular pressure measurement: an evaluation of the potential impact on clinical decision making in glaucoma. Carrim ZI; Lavy TE Ophthalmic Physiol Opt; 2009 Nov; 29(6):648-51. PubMed ID: 19821927 [TBL] [Abstract][Full Text] [Related]
18. Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen. Bhan A; Browning AC; Shah S; Hamilton R; Dave D; Dua HS Invest Ophthalmol Vis Sci; 2002 May; 43(5):1389-92. PubMed ID: 11980851 [TBL] [Abstract][Full Text] [Related]
19. Comparison of two handheld applanation tonometers and the association of central corneal thickness, age, and intraocular pressure in normal and diseased canine eyes. Kato K Vet Ophthalmol; 2014 Nov; 17(6):417-25. PubMed ID: 24517734 [TBL] [Abstract][Full Text] [Related]
20. Tono-Pen determination of intraocular pressure in patients with band keratopathy or glued cornea. Azuara-Blanco A; Bhojani TK; Sarhan AR; Pillai CT; Dua HS Br J Ophthalmol; 1998 Jun; 82(6):634-6. PubMed ID: 9797663 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]