307 related articles for article (PubMed ID: 3258215)
1. Technetium-99m labeled RBC imaging in gastrointestinal bleeding from gastric leiomyoma.
Joseph UA; Jhingran SG
Clin Nucl Med; 1988 Jan; 13(1):23-5. PubMed ID: 3258215
[TBL] [Abstract][Full Text] [Related]
2. Comparison of technetium-99m sulfur colloid and in vitro labeled technetium-99m RBCs in the detection of gastrointestinal bleeding.
Siddiqui AR; Schauwecker DS; Wellman HN; Mock BH
Clin Nucl Med; 1985 Aug; 10(8):546-9. PubMed ID: 3876189
[TBL] [Abstract][Full Text] [Related]
3. Comparison of four technetium-99m radiopharmaceuticals for detection and localization of gastrointestinal bleeding in a sheep model.
Owunwanne A; Al-Wafai I; Vallgren S; Sadek S; Abdel-Dayem HM; Yacoub T
Am J Physiol Imaging; 1988; 3(4):192-6. PubMed ID: 2975183
[TBL] [Abstract][Full Text] [Related]
4. Tc-99m sulfur colloid and Tc-99m tagged red blood cell methods are comparable for detecting lower gastrointestinal bleeding in clinical practice.
Ponzo F; Zhuang H; Liu FM; Lacorte LB; Moussavian B; Wang S; Alavi A
Clin Nucl Med; 2002 Jun; 27(6):405-9. PubMed ID: 12045430
[TBL] [Abstract][Full Text] [Related]
5. Accuracy of 99mTechnetium-labeled RBC Scintigraphy and MDCT With Gastrointestinal Bleed Protocol for Detection and Localization of Source of Acute Lower Gastrointestinal Bleeding.
Awais M; Haq TU; Rehman A; Zaman MU; Haider Z; Khattak YJ; Baloch NU
J Clin Gastroenterol; 2016 Oct; 50(9):754-60. PubMed ID: 26646804
[TBL] [Abstract][Full Text] [Related]
6. [Negative endoscopy and MSCT findings in patients with acute lower gastrointestinal hemorrhage. Value of (99m)Tc erythrocyte scintigraphy].
Diehl SJ; Ko HS; Dominguez E; Kaare Tesdal I; Kähler G; Böhm C; Düber C
Radiologe; 2007 Jan; 47(1):64-70. PubMed ID: 17096110
[TBL] [Abstract][Full Text] [Related]
7. Acute Lower Gastrointestinal Bleeding: Temporal Factors Associated With Positive Findings on Catheter Angiography After (99m)Tc-Labeled RBC Scanning.
Chung M; Dubel GJ; Noto RB; Yoo DC; Baird GL; Prince EA; Murphy TP; Haaga TL; Ahn SH
AJR Am J Roentgenol; 2016 Jul; 207(1):170-6. PubMed ID: 27101433
[TBL] [Abstract][Full Text] [Related]
8. The role of nuclear medicine in the detection of acute gastrointestinal bleeding.
Howarth DM
Semin Nucl Med; 2006 Apr; 36(2):133-46. PubMed ID: 16517235
[TBL] [Abstract][Full Text] [Related]
9. Noninvasive evaluation of active lower gastrointestinal bleeding: comparison between contrast-enhanced MDCT and 99mTc-labeled RBC scintigraphy.
Zink SI; Ohki SK; Stein B; Zambuto DA; Rosenberg RJ; Choi JJ; Tubbs DS
AJR Am J Roentgenol; 2008 Oct; 191(4):1107-14. PubMed ID: 18806152
[TBL] [Abstract][Full Text] [Related]
10. False positive GI bleed on Tc-99m RBC scintigraphy due to ileal varices.
Chen PN; Brown RK
J Radiol Case Rep; 2012 Feb; 6(2):23-8. PubMed ID: 22690283
[TBL] [Abstract][Full Text] [Related]
11. Localization of small bowel bleeding by arterial injection of Tc-99m-labeled RBC.
Saito K; Koizumi K; Goto Y; Yamamoto K; Abe K
Ann Nucl Med; 1999 Jun; 13(3):191-4. PubMed ID: 10435381
[TBL] [Abstract][Full Text] [Related]
12. Scintigraphic demonstration of acute gastrointestinal bleeding caused by gallbladder carcinoma eroding the colon.
Czerniak A; Zwas ST; Rabau MY; Avigad I; Borag B; Wolfstein I
Clin Nucl Med; 1985 Aug; 10(8):543-5. PubMed ID: 3876188
[TBL] [Abstract][Full Text] [Related]
13. Combined 99mTc-sulfide colloid and 99mTc-RBC studies for localization of gastrointestinal bleeding sites.
Chu DD; Lentle BC; Szasz IJ
AJR Am J Roentgenol; 1989 Mar; 152(3):653-4. PubMed ID: 2783825
[No Abstract] [Full Text] [Related]
14. Intraperitoneal bleeding demonstrated by Tc-99m labeled red blood cell scintigraphy.
Ben-Haim S; Rezai K
Clin Nucl Med; 1992 Oct; 17(10):789-90. PubMed ID: 1424353
[TBL] [Abstract][Full Text] [Related]
15. Tc-99m RBC imaging for demonstrating intermittent intestinal bleeding.
Morita S; Ishibashi M; Yoshii T; Hirayama T; Takahashi K; Kobayashi R; Kaku N; Ohtake H
Kurume Med J; 1990; 37(1):41-3. PubMed ID: 2214677
[TBL] [Abstract][Full Text] [Related]
16. Implications of negative technetium 99m-labeled red blood cell scintigraphy in patients presenting with lower gastrointestinal bleeding.
Hammond KL; Beck DE; Hicks TC; Timmcke AE; Whitlow CW; Margolin DA
Am J Surg; 2007 Mar; 193(3):404-7; discussion 407-8. PubMed ID: 17320544
[TBL] [Abstract][Full Text] [Related]
17. Evaluation of gastrointestinal bleeding by red blood cells labeled in vivo with technetium-99m.
Winzelberg GG; McKusick KA; Strauss HW; Waltman AC; Greenfield AJ
J Nucl Med; 1979 Oct; 20(10):1080-6. PubMed ID: 317093
[TBL] [Abstract][Full Text] [Related]
18. Fibroid uterus confounding the correct localization of active gastrointestinal bleeding during Tc-99m RBC scan.
Gafton AR; Caride VJ
Clin Nucl Med; 2006 Aug; 31(8):508-10. PubMed ID: 16855448
[No Abstract] [Full Text] [Related]
19. Bleeding rates necessary for detecting acute gastrointestinal bleeding with technetium-99m-labeled red blood cells in an experimental model.
Thorne DA; Datz FL; Remley K; Christian PE
J Nucl Med; 1987 Apr; 28(4):514-20. PubMed ID: 3494826
[TBL] [Abstract][Full Text] [Related]
20. Scintigraphic detection of gastrointestinal bleeding: a review of current methods.
Winzelberg GG; Froelich JW; McKusick KA; Strauss HW
Am J Gastroenterol; 1983 Jun; 78(6):324-7. PubMed ID: 6602543
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]