BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

171 related articles for article (PubMed ID: 32583484)

  • 1. Scintillation imaging as a high-resolution, remote, versatile 2D detection system for MR-linac quality assurance.
    Alexander DA; Zhang R; Brůža P; Pogue BW; Gladstone DJ
    Med Phys; 2020 Sep; 47(9):3861-3869. PubMed ID: 32583484
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Characterization of positional accuracy of a double-focused and double-stack multileaf collimator on an MR-guided radiotherapy (MRgRT) Linac using an IC-profiler array.
    Mittauer KE; Yadav P; Paliwal B; Bayouth JE
    Med Phys; 2020 Feb; 47(2):317-330. PubMed ID: 31682018
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Cherenkov imaging for linac beam shape analysis as a remote electronic quality assessment verification tool.
    Miao T; Bruza P; Pogue BW; Jermyn M; Krishnaswamy V; Ware W; Rafie F; Gladstone DJ; Williams BB
    Med Phys; 2019 Feb; 46(2):811-821. PubMed ID: 30471126
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Optical emission-based phantom to verify coincidence of radiotherapy and imaging isocenters on an MR-linac.
    Andreozzi JM; Brůža P; Cammin J; Alexander DA; Pogue BW; Green O; Gladstone DJ
    J Appl Clin Med Phys; 2021 Sep; 22(9):252-261. PubMed ID: 34409766
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Characterization and longitudinal assessment of daily quality assurance for an MR-guided radiotherapy (MRgRT) linac.
    Mittauer KE; Dunkerley DAP; Yadav P; Bayouth JE
    J Appl Clin Med Phys; 2019 Nov; 20(11):27-36. PubMed ID: 31633882
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Daily QA of linear accelerators using only EPID and OBI.
    Sun B; Goddu SM; Yaddanapudi S; Noel C; Li H; Cai B; Kavanaugh J; Mutic S
    Med Phys; 2015 Oct; 42(10):5584-94. PubMed ID: 26429233
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Feasibility of using a transmission ion chamber for QA tests of medical linear accelerators.
    Farrokhkish M; Veres AJ; Fong de Los Santos LE; DeMarco JJ; Islam MK
    J Appl Clin Med Phys; 2024 Feb; 25(2):e14245. PubMed ID: 38194595
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Longitudinal assessment of quality assurance measurements in a 1.5T MR-linac: Part I-Linear accelerator.
    Subashi E; Lim SB; Gonzalez X; Tyagi N
    J Appl Clin Med Phys; 2021 Oct; 22(10):190-201. PubMed ID: 34505349
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Small-field measurement and Monte Carlo model validation of a novel image-guided radiotherapy system.
    Shi M; Chuang CF; Kovalchuk N; Bush K; Zaks D; Xing L; Surucu M; Han B
    Med Phys; 2021 Nov; 48(11):7450-7460. PubMed ID: 34628666
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Factor 10 Expedience of Monthly Linac Quality Assurance via an Ion Chamber Array and Automation Scripts.
    Skinner LB; Yang Y; Hsu A; Xing L; Yu AS; Niedermayr T
    Technol Cancer Res Treat; 2019; 18():1533033819876897. PubMed ID: 31707931
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Characterizing MR Imaging isocenter variation in MRgRT.
    Kim T; Gu B; Maraghechi B; Green O; Lewis B; Mutic S; Gach HM
    Biomed Phys Eng Express; 2020 Mar; 6(3):035009. PubMed ID: 33438654
    [TBL] [Abstract][Full Text] [Related]  

  • 12. 3D star shot analysis using MAGAT gel dosimeter for integrated imaging and radiation isocenter verification of MR-Linac system.
    Kim JH; Kim B; Shin WG; Son J; Choi CH; Park JM; Hwang UJ; Kim JI; Jung S
    J Appl Clin Med Phys; 2022 Jun; 23(6):e13615. PubMed ID: 35436031
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Performance of a multileaf collimator system for a 1.5T MR-linac.
    Zhang K; Tian Y; Li M; Men K; Dai J
    Med Phys; 2021 Feb; 48(2):546-555. PubMed ID: 33219549
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Remote Cherenkov imaging-based quality assurance of a magnetic resonance image-guided radiotherapy system.
    Andreozzi JM; Mooney KE; Brůža P; Curcuru A; Gladstone DJ; Pogue BW; Green O
    Med Phys; 2018 Jun; 45(6):2647-2659. PubMed ID: 29663429
    [TBL] [Abstract][Full Text] [Related]  

  • 15. MOSFET dosimeter characterization in MR-guided radiation therapy (MRgRT) Linac.
    Yadav P; Hallil A; Tewatia D; Dunkerley DAP; Paliwal B
    J Appl Clin Med Phys; 2020 Jan; 21(1):127-135. PubMed ID: 31854078
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Characterization of mechanical and radiation isocenter on an MR-guided radiotherapy (MRgRT) Linac.
    Bassiri N; Bayouth JE; Mittauer KE
    J Appl Clin Med Phys; 2023 Nov; 24(11):e14111. PubMed ID: 37535938
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A daily end-to-end quality assurance workflow for MR-guided online adaptive radiation therapy on MR-Linac.
    Chen X; Ahunbay E; Paulson ES; Chen G; Li XA
    J Appl Clin Med Phys; 2020 Jan; 21(1):205-212. PubMed ID: 31799753
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dosimetric characterization of a novel commercial plastic scintillation detector with an MR-Linac.
    Ferrer C; Huertas C; García D; Sáez M
    Med Phys; 2023 Apr; 50(4):2525-2539. PubMed ID: 36611266
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measuring output factors of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors.
    Klein DM; Tailor RC; Archambault L; Wang L; Therriault-Proulx F; Beddar AS
    Med Phys; 2010 Oct; 37(10):5541-9. PubMed ID: 21089789
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Characterization and evaluation of an integrated quality monitoring system for online quality assurance of external beam radiation therapy.
    Hoffman D; Chung E; Hess C; Stern R; Benedict S
    J Appl Clin Med Phys; 2017 Jan; 18(1):40-48. PubMed ID: 28291937
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.