These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 32585940)

  • 1. The Impact of EBM-Manufactured Ti6Al4V ELI Alloy Surface Modifications on Cytotoxicity toward Eukaryotic Cells and Microbial Biofilm Formation.
    Szymczyk-Ziółkowska P; Hoppe V; Rusińska M; Gąsiorek J; Ziółkowski G; Dydak K; Czajkowska J; Junka A
    Materials (Basel); 2020 Jun; 13(12):. PubMed ID: 32585940
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vitro dermal and epidermal cellular response to titanium alloy implants fabricated with electron beam melting.
    Springer JC; Harrysson OL; Marcellin-Little DJ; Bernacki SH
    Med Eng Phys; 2014 Oct; 36(10):1367-72. PubMed ID: 25080895
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of Various Peening Methods on the Fatigue Properties of Titanium Alloy Ti6Al4V Manufactured by Direct Metal Laser Sintering and Electron Beam Melting.
    Soyama H; Takeo F
    Materials (Basel); 2020 May; 13(10):. PubMed ID: 32408590
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Influence of Inherent Surface and Internal Defects on Mechanical Properties of Additively Manufactured Ti6Al4V Alloy: Comparison between Selective Laser Melting and Electron Beam Melting.
    Fousová M; Vojtěch D; Doubrava K; Daniel M; Lin CF
    Materials (Basel); 2018 Mar; 11(4):. PubMed ID: 29614712
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Mechanical evaluation of porous titanium (Ti6Al4V) structures with electron beam melting (EBM).
    Parthasarathy J; Starly B; Raman S; Christensen A
    J Mech Behav Biomed Mater; 2010 Apr; 3(3):249-59. PubMed ID: 20142109
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Long-term osseointegration of 3D printed CoCr constructs with an interconnected open-pore architecture prepared by electron beam melting.
    Shah FA; Omar O; Suska F; Snis A; Matic A; Emanuelsson L; Norlindh B; Lausmaa J; Thomsen P; Palmquist A
    Acta Biomater; 2016 May; 36():296-309. PubMed ID: 27000553
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hierarchical micro-nano structured Ti6Al4V surface topography via two-step etching process for enhanced hydrophilicity and osteoblastic responses.
    Moon BS; Kim S; Kim HE; Jang TS
    Mater Sci Eng C Mater Biol Appl; 2017 Apr; 73():90-98. PubMed ID: 28183677
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comprehensive Biological Evaluation of Biomaterials Used in Spinal and Orthopedic Surgery.
    Komorowski P; Siatkowska M; Kamińska M; Jakubowski W; Walczyńska M; Walkowiak-Przybyło M; Szymański W; Piersa K; Wielowski P; Sokołowska P; Białkowska K; Makowski K; Elgalal M; Kierzkowska A; Ciupik L; Walkowiak B
    Materials (Basel); 2020 Oct; 13(21):. PubMed ID: 33114571
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Additive manufacturing of Ti6Al4V alloy via electron beam melting for the development of implants for the biomedical industry.
    Tamayo JA; Riascos M; Vargas CA; Baena LM
    Heliyon; 2021 May; 7(5):e06892. PubMed ID: 34027149
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Micro- to Macroroughness of Additively Manufactured Titanium Implants in Terms of Coagulation and Contact Activation.
    Klingvall Ek R; Hong J; Thor A; Bäckström M; Rännar LE
    Int J Oral Maxillofac Implants; 2017; 32(3):565-574. PubMed ID: 28494040
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Surface zwitterionization of customized 3D Ti6Al4V scaffolds: a promising alternative to eradicate bone infection.
    Rodriguez-Palomo A; Monopoli D; Afonso H; Izquierdo-Barba I; Vallet-Regí M
    J Mater Chem B; 2016 Jun; 4(24):4356-4365. PubMed ID: 32263418
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Encapsulation of Electron Beam Melting Produced Alloy 718 to Reduce Surface Connected Defects by Hot Isostatic Pressing.
    Zafer YE; Goel S; Ganvir A; Jansson A; Joshi S
    Materials (Basel); 2020 Mar; 13(5):. PubMed ID: 32182804
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A Comparison of Biocompatibility of a Titanium Alloy Fabricated by Electron Beam Melting and Selective Laser Melting.
    Wang H; Zhao B; Liu C; Wang C; Tan X; Hu M
    PLoS One; 2016; 11(7):e0158513. PubMed ID: 27391895
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In vitro cytotoxicity and surface topography evaluation of additive manufacturing titanium implant materials.
    Tuomi JT; Björkstrand RV; Pernu ML; Salmi MV; Huotilainen EI; Wolff JE; Vallittu PK; Mäkitie AA
    J Mater Sci Mater Med; 2017 Mar; 28(3):53. PubMed ID: 28197824
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The chemical digestion of Ti6Al7Nb scaffolds produced by Selective Laser Melting reduces significantly ability of Pseudomonas aeruginosa to form biofilm.
    Junka AF; Szymczyk P; Secewicz A; Pawlak A; Smutnicka D; Ziółkowski G; Bartoszewicz M; Chlebus E
    Acta Bioeng Biomech; 2016; 18(1):115-20. PubMed ID: 27150429
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Topological, Mechanical and Biological Properties of Ti6Al4V Scaffolds for Bone Tissue Regeneration Fabricated with Reused Powders via Electron Beam Melting.
    Gatto ML; Groppo R; Bloise N; Fassina L; Visai L; Galati M; Iuliano L; Mengucci P
    Materials (Basel); 2021 Jan; 14(1):. PubMed ID: 33466387
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hydrophilic surface of Ti6Al4V-ELI alloy improves the early bone apposition of sheep tibia.
    Sartoretto SC; Alves ATNN; Zarranz L; Jorge MZ; Granjeiro JM; Calasans-Maia MD
    Clin Oral Implants Res; 2017 Aug; 28(8):893-901. PubMed ID: 27317626
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Microstructure and mechanical properties of porous titanium structures fabricated by electron beam melting for cranial implants.
    Moiduddin K
    Proc Inst Mech Eng H; 2018 Feb; 232(2):185-199. PubMed ID: 29332500
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of Alkali-Acid-Heat Chemical Surface Treatment on Electron Beam Melted Porous Titanium and Its Apatite Forming Ability.
    Bsat S; Yavari SA; Munsch M; Valstar ER; Zadpoor AA
    Materials (Basel); 2015 Apr; 8(4):1612-1625. PubMed ID: 28788021
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Antibacterial and Biocompatible Titanium-Copper Oxide Coating May Be a Potential Strategy to Reduce Periprosthetic Infection: An In Vitro Study.
    Norambuena GA; Patel R; Karau M; Wyles CC; Jannetto PJ; Bennet KE; Hanssen AD; Sierra RJ
    Clin Orthop Relat Res; 2017 Mar; 475(3):722-732. PubMed ID: 26847453
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.