These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 3259666)

  • 1. Solid-phase optoelectronic biosensors.
    Lowe CR; Goldfinch MJ
    Methods Enzymol; 1988; 137():338-48. PubMed ID: 3259666
    [No Abstract]   [Full Text] [Related]  

  • 2. Solid-phase optoelectronic sensors for biochemical analysis.
    Goldfinch MJ; Lowe CR
    Anal Biochem; 1984 May; 138(2):430-6. PubMed ID: 6742421
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Metabolite-sensitive holographic biosensors.
    Marshall AJ; Young DS; Blyth J; Kabilan S; Lowe CR
    Anal Chem; 2004 Mar; 76(5):1518-23. PubMed ID: 14987112
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Enzyme thermistor devices.
    Danielsson B; Mosbach K
    Methods Enzymol; 1976; 44():667-76. PubMed ID: 1021698
    [No Abstract]   [Full Text] [Related]  

  • 5. An integrated silicon thermophile as biosensor for the thermal monitoring of glucose, urea and penicillin.
    Bataillard P; Steffgen E; Haemmerli S; Manz A; Widmer HM
    Biosens Bioelectron; 1993; 8(2):89-98. PubMed ID: 8318196
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dielectric-based biosensors.
    Pethig R
    Biochem Soc Trans; 1991 Feb; 19(1):21-5. PubMed ID: 2037151
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Automated serum albumin determination by use of the immediate reaction with bromcresol green reagent.
    Gustafsson JE
    Clin Chem; 1978 Feb; 24(2):369-73. PubMed ID: 627076
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Continuous-flow analysis for serum albumin, by use of the immediate reaction with bromcresol green.
    Plesher CJ
    Clin Chem; 1978 Nov; 24(11):2036-9. PubMed ID: 709843
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Albumin I.M.V.S.: a variant detected by a Bromcresol Green dye binding method.
    Walsh RL; Need AG; Coles ME
    Clin Chim Acta; 1983 May; 130(1):11-23. PubMed ID: 6851178
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Improved continuous-flow determination of albumin with bromcresol green.
    von Schenck H; Rebel K
    Clin Chem; 1982 Jun; 28(6):1408-9. PubMed ID: 7074963
    [No Abstract]   [Full Text] [Related]  

  • 11. [An improved method for selective determination of serum albumin by the bromcresol green method, using the SMAR 12/60 (author's transl)].
    Keller F; Feldmann K; Metz FJ
    J Clin Chem Clin Biochem; 1981 Mar; 19(3):169-71. PubMed ID: 7229581
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Automated stopped-flow analyser in clinical chemistry: determination of albumin with bromcresol green and purple.
    Koupparis MA; Diamandis EP; Malmstadt HV
    Clin Chim Acta; 1985 Jul; 149(2-3):225-35. PubMed ID: 4028442
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Salivary urea nitrogen as an index to renal function: a test-strip method.
    Akai T; Naka K; Yoshikawa C; Okuda K; Okamoto T; Yamagami S; Inoue T; Yamao Y; Yamada S
    Clin Chem; 1983 Oct; 29(10):1825-7. PubMed ID: 6616832
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Flow-injection analysis for automated determination of beta-lactams using immobilized enzyme reactors with thermistor or ultraviolet spectrophotometric detection.
    Decristoforo G
    Methods Enzymol; 1988; 137():197-217. PubMed ID: 3259665
    [No Abstract]   [Full Text] [Related]  

  • 15. Automated albumin method underestimates pharmaceutical-grade albumin in vivo.
    Børmer OP; Amlie LM; Paus E; Kongsgård U
    Clin Chem; 1999 Jul; 45(7):1082-4. PubMed ID: 10388486
    [No Abstract]   [Full Text] [Related]  

  • 16. Insulator semiconductor structures coated with biodegradable latexes as encapsulation matrix for urease.
    Barhoumi H; Maaref A; Rammah M; Martelet C; Jaffrezic-Renault N; Mousty C; Cosnier S; Perez E; Rico-Lattes I
    Biosens Bioelectron; 2005 May; 20(11):2318-23. PubMed ID: 15797333
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Improved continuous-flow (SMAC) determination of serum albumin.
    Cederblad G; Hickey BE; Hollender A; Akerlund G
    Clin Chem; 1978 Jul; 24(7):1191-3. PubMed ID: 657502
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Kinetic determination of urea with the LKB system (author's transl)].
    Eisenwiener HG
    J Clin Chem Clin Biochem; 1976 Jun; 14(6):261-4. PubMed ID: 956732
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development of penicillin G biosensor based on penicillinase enzymes immobilized onto bio-chips.
    Rahman MM; Asiri AM
    Biomed Microdevices; 2015 Feb; 17(1):9. PubMed ID: 25653059
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Urea potentiometric biosensor based on modified electrodes with urease immobilized on polyethylenimine films.
    Lakard B; Herlem G; Lakard S; Antoniou A; Fahys B
    Biosens Bioelectron; 2004 Jul; 19(12):1641-7. PubMed ID: 15142598
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.