267 related articles for article (PubMed ID: 32600130)
1. Ten years on: increased metal ion levels in a cohort of patients who underwent uncemented metal-on-polyethylene total hip arthroplasty.
Dover C; Kuiper JH; Craig P; Shaylor P
Bone Joint J; 2020 Jul; 102-B(7):832-837. PubMed ID: 32600130
[TBL] [Abstract][Full Text] [Related]
2. Raised levels of metal ions in the blood in patients who have undergone uncemented metal-on-polyethylene Trident-Accolade total hip replacement.
Craig P; Bancroft G; Burton A; Collier S; Shaylor P; Sinha A
Bone Joint J; 2014 Jan; 96-B(1):43-7. PubMed ID: 24395309
[TBL] [Abstract][Full Text] [Related]
3. Ten-year outcome of serum metal ion levels after primary total hip arthroplasty: a concise follow-up of a previous report*.
Levine BR; Hsu AR; Skipor AK; Hallab NJ; Paprosky WG; Galante JO; Jacobs JJ
J Bone Joint Surg Am; 2013 Mar; 95(6):512-8. PubMed ID: 23515985
[TBL] [Abstract][Full Text] [Related]
4. Blood metal ions after hybrid metal-on-polyethylene Exeter-Trident total hip replacement.
Singh R; Manoharan G; Craig P; Collier S; Shaylor P; Sinha A
J Orthop Traumatol; 2016 Jun; 17(2):149-53. PubMed ID: 26206329
[TBL] [Abstract][Full Text] [Related]
5. Comparison of whole-blood metal ion levels in four types of metal-on-metal large-diameter femoral head total hip arthroplasty: the potential influence of the adapter sleeve.
Lavigne M; Belzile EL; Roy A; Morin F; Amzica T; Vendittoli PA
J Bone Joint Surg Am; 2011 May; 93 Suppl 2():128-36. PubMed ID: 21543702
[TBL] [Abstract][Full Text] [Related]
6. A Comparison of Blood Metal Ions in Total Hip Arthroplasty Using Metal and Ceramic Heads.
White PB; Meftah M; Ranawat AS; Ranawat CS
J Arthroplasty; 2016 Oct; 31(10):2215-20. PubMed ID: 27108055
[TBL] [Abstract][Full Text] [Related]
7. The Fate of Elevated Metal Ion Levels After Revision Surgery for Head-Neck Taper Corrosion in Patients With Metal-on-Polyethylene Total Hip Arthroplasty.
Kwon YM; MacAuliffe J; Peng Y; Arauz P
J Arthroplasty; 2018 Aug; 33(8):2631-2635. PubMed ID: 29691164
[TBL] [Abstract][Full Text] [Related]
8. Increased Femoral Head Offset is Associated With Elevated Metal Ions in Asymptomatic Patients With Metal-on-Polyethylene Total Hip Arthroplasty.
Martin JR; Camp CL; Wyles CC; Taunton MJ; Trousdale RT; Lewallen DG
J Arthroplasty; 2016 Dec; 31(12):2814-2818. PubMed ID: 27436501
[TBL] [Abstract][Full Text] [Related]
9. Surveillance of Patients with Metal-on-Metal Hip Resurfacing and Total Hip Prostheses: A Prospective Cohort Study to Investigate the Relationship Between Blood Metal Ion Levels and Implant Failure.
Hart AJ; Sabah SA; Sampson B; Skinner JA; Powell JJ; Palla L; Pajamäki KJ; Puolakka T; Reito A; Eskelinen A
J Bone Joint Surg Am; 2014 Jul; 96(13):1091-1099. PubMed ID: 24990974
[TBL] [Abstract][Full Text] [Related]
10. Uniformly low serum cobalt levels after modular dual-mobility total hip arthroplasties with ceramic heads: a prospective study in high-risk patients.
Chalmers BP; Mangold DG; Hanssen AD; Pagnano MW; Trousdale RT; Abdel MP
Bone Joint J; 2019 Jun; 101-B(6_Supple_B):57-61. PubMed ID: 31146553
[TBL] [Abstract][Full Text] [Related]
11. The effect of different bearing surfaces on metal ion levels in urine following 28 mm metal-on-metal and 28 mm metal-on-polyethylene total hip arthroplasty.
Tiusanen H; Mäkelä K; Kiilunen M; Sarantsin P; Sipola E; Pesola M
Scand J Surg; 2013; 102(3):197-203. PubMed ID: 23963035
[TBL] [Abstract][Full Text] [Related]
12. What Are Normal Metal Ion Levels After Total Hip Arthroplasty? A Serologic Analysis of Four Bearing Surfaces.
Barlow BT; Ortiz PA; Boles JW; Lee YY; Padgett DE; Westrich GH
J Arthroplasty; 2017 May; 32(5):1535-1542. PubMed ID: 28190644
[TBL] [Abstract][Full Text] [Related]
13. Two-year serum metal ion levels in minimally invasive total conservative hip resurfacing: preliminary results of a prospective study.
Tai SM; Millard N; Munir S; Jenabzadeh AR; Walter LR; Walter WL
ANZ J Surg; 2015 Mar; 85(3):164-8. PubMed ID: 25288230
[TBL] [Abstract][Full Text] [Related]
14. The incidence of adverse local tissue reaction due to head taper corrosion after total hip arthroplasty using V40 taper and 36 mm CoCr head.
Grothe T; Günther KP; Hartmann A; Blum S; Haselhoff R; Goronzy J
Bone Joint J; 2022 Jul; 104-B(7):852-858. PubMed ID: 35775169
[TBL] [Abstract][Full Text] [Related]
15. [Metal serum levels in 48 patients bearing a chromium-cobalt total hip arthroplasty with a metal-on-polyethylene combination].
Damie F; Favard L
Rev Chir Orthop Reparatrice Appar Mot; 2004 May; 90(3):241-8. PubMed ID: 15211273
[TBL] [Abstract][Full Text] [Related]
16. Femoral offset found not to affect metal ion levels in metal-on-metal total hip arthroplasty.
Pomeroy E; Macnamara F; Murphy E; McGoldrick N; Mahapatra A; Awan N
Ir J Med Sci; 2019 Feb; 188(1):149-153. PubMed ID: 29732504
[TBL] [Abstract][Full Text] [Related]
17. Gross trunnion failure in metal on polyethylene total hip arthroplasty-a systematic review of literature.
Bansal T; Aggarwal S; Dhillon MS; Patel S
Int Orthop; 2020 Apr; 44(4):609-621. PubMed ID: 31900575
[TBL] [Abstract][Full Text] [Related]
18. Comparison of Whole-Blood Metal Ion Levels Among Four Types of Large-Head, Metal-on-Metal Total Hip Arthroplasty Implants: A Concise Follow-up, at Five Years, of a Previous Report.
Hutt J; Lavigne M; Lungu E; Belzile E; Morin F; Vendittoli PA
J Bone Joint Surg Am; 2016 Feb; 98(4):257-66. PubMed ID: 26888673
[TBL] [Abstract][Full Text] [Related]
19. One-year prospective comparative study of three large-diameter metal-on-metal total hip prostheses: serum metal ion levels and clinical outcomes.
Lardanchet JF; Taviaux J; Arnalsteen D; Gabrion A; Mertl P
Orthop Traumatol Surg Res; 2012 May; 98(3):265-74. PubMed ID: 22480865
[TBL] [Abstract][Full Text] [Related]
20. Surface integrity of polyethylene liners following trunnionosis of a dual modular neck total hip implant.
Spiegelberg BG; Lanting BA; Howard JL; Teeter MG; Naudie DD
Hip Int; 2018 Nov; 28(6):629-635. PubMed ID: 29756511
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]