These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

237 related articles for article (PubMed ID: 32602018)

  • 1. Simultaneous determination of heavy metals by an electrochemical method based on a nanocomposite consisting of fluorinated graphene and gold nanocage.
    Tan Z; Wu W; Feng C; Wu H; Zhang Z
    Mikrochim Acta; 2020 Jun; 187(7):414. PubMed ID: 32602018
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Simultaneous voltammetric determination of cadmium(II), lead(II), mercury(II), zinc(II), and copper(II) using a glassy carbon electrode modified with magnetite (Fe
    Wu W; Jia M; Wang Z; Zhang W; Zhang Q; Liu G; Zhang Z; Li P
    Mikrochim Acta; 2019 Jan; 186(2):97. PubMed ID: 30631955
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Voltammetric determination of cadmium(II), lead(II) and copper(II) with a glassy carbon electrode modified with silver nanoparticles deposited on poly(1,8-diaminonaphthalene).
    Hassan KM; Elhaddad GM; AbdelAzzem M
    Mikrochim Acta; 2019 Jun; 186(7):440. PubMed ID: 31197477
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A nanocomposite consisting of ionic liquid-functionalized layered Mg(II)/Al(III) double hydroxides for simultaneous electrochemical determination of cadmium(II), copper(II), mercury(II) and lead(II).
    Zhou J; Sun G; Pan J; Pan Y; Wang S; Zhai H
    Mikrochim Acta; 2019 Nov; 186(12):767. PubMed ID: 31713688
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Fullerene-based anodic stripping voltammetry for simultaneous determination of Hg(II), Cu(II), Pb(II) and Cd(II) in foodstuff.
    Han X; Meng Z; Zhang H; Zheng J
    Mikrochim Acta; 2018 May; 185(5):274. PubMed ID: 29717357
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A nanocomposite consisting of porous graphitic carbon nitride nanosheets and oxidized multiwalled carbon nanotubes for simultaneous stripping voltammetric determination of cadmium(II), mercury(II), lead(II) and zinc(II).
    Ramalingam M; Ponnusamy VK; Sangilimuthu SN
    Mikrochim Acta; 2019 Jan; 186(2):69. PubMed ID: 30627931
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Metallo-graphene nanocomposite electrocatalytic platform for the determination of toxic metal ions.
    Willemse CM; Tlhomelang K; Jahed N; Baker PG; Iwuoha EI
    Sensors (Basel); 2011; 11(4):3970-87. PubMed ID: 22163831
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Sensitive electrochemical sensor using a graphene-polyaniline nanocomposite for simultaneous detection of Zn(II), Cd(II), and Pb(II).
    Ruecha N; Rodthongkum N; Cate DM; Volckens J; Chailapakul O; Henry CS
    Anal Chim Acta; 2015 May; 874():40-8. PubMed ID: 25910444
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Stainless steel electrode for simultaneous stripping analysis of Cd(II), Pb(II), Cu(II) and Hg(II).
    Kitte SA; Li S; Nsabimana A; Gao W; Lai J; Liu Z; Xu G
    Talanta; 2019 Jan; 191():485-490. PubMed ID: 30262089
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A glassy carbon electrode modified with a bismuth film and laser etched graphene for simultaneous voltammetric sensing of Cd(II) and Pb(II).
    Lin X; Lu Z; Zhang Y; Liu B; Mo G; Li J; Ye J
    Mikrochim Acta; 2018 Aug; 185(9):438. PubMed ID: 30167785
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Simultaneous analysis of Pb
    Kiliç HD; Kizil H
    Anal Bioanal Chem; 2019 Dec; 411(30):8113-8121. PubMed ID: 31768591
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A sensitive electrochemical sensor using an iron oxide/graphene composite for the simultaneous detection of heavy metal ions.
    Lee S; Oh J; Kim D; Piao Y
    Talanta; 2016 Nov; 160():528-536. PubMed ID: 27591647
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Non-conductive nanomaterial enhanced electrochemical response in stripping voltammetry: The use of nanostructured magnesium silicate hollow spheres for heavy metal ions detection.
    Xu RX; Yu XY; Gao C; Jiang YJ; Han DD; Liu JH; Huang XJ
    Anal Chim Acta; 2013 Aug; 790():31-8. PubMed ID: 23870406
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fabrication and application of a new modified electrochemical sensor using nano-silica and a newly synthesized Schiff base for simultaneous determination of Cd2+, Cu2+ and Hg2+ ions in water and some foodstuff samples.
    Afkhami A; Soltani-Felehgari F; Madrakian T; Ghaedi H; Rezaeivala M
    Anal Chim Acta; 2013 Apr; 771():21-30. PubMed ID: 23522108
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Electrochemical sensors for the simultaneous determination of zinc, cadmium and lead using a Nafion/ionic liquid/graphene composite modified screen-printed carbon electrode.
    Chaiyo S; Mehmeti E; Žagar K; Siangproh W; Chailapakul O; Kalcher K
    Anal Chim Acta; 2016 Apr; 918():26-34. PubMed ID: 27046207
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Simultaneous electrochemical determination of arsenic, copper, lead and mercury in unpolluted fresh waters using a vibrating gold microwire electrode.
    Alves GM; Magalhães JM; Salaün P; van den Berg CM; Soares HM
    Anal Chim Acta; 2011 Oct; 703(1):1-7. PubMed ID: 21843669
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A micromilled microgrid sensor with delaminated MXene-bismuth nanocomposite assembly for simultaneous electrochemical detection of lead(II), cadmium(II) and zinc(II).
    Zhu X; Liu B; Li L; Wu L; Chen S; Huang L; Yang J; Liang S; Xiao K; Hu J; Hou H
    Mikrochim Acta; 2019 Nov; 186(12):776. PubMed ID: 31728707
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Square-wave anodic-stripping voltammetric determination of Cd, Pb, and Cu in a hydrofluoric acid solution of siliceous spicules of marine sponges (from the Ligurian Sea, Italy, and the Ross Sea, Antarctica).
    Truzzi C; Annibaldi A; Illuminati S; Bassotti E; Scarponi G
    Anal Bioanal Chem; 2008 Sep; 392(1-2):247-62. PubMed ID: 18642105
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Sequential injection anodic stripping voltammetry with monosegmented flow and in-line UV digestion for determination of Zn(II), Cd(II), Pb(II) and Cu(II) in water samples.
    Siriangkhawut W; Grudpan K; Jakmunee J
    Talanta; 2011 Jun; 84(5):1366-73. PubMed ID: 21641453
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A disposable chronocoulometric sensor for heavy metal ions using a diaminoterthiophene-modified electrode doped with graphene oxide.
    Choi SM; Kim DM; Jung OS; Shim YB
    Anal Chim Acta; 2015 Sep; 892():77-84. PubMed ID: 26388477
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.