These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
219 related articles for article (PubMed ID: 32603444)
1. Evaluation of an Ion-Exchange HPLC Device for HbA1c Measurement. Altawallbeh G; Makky VF; Saenger AK; Peters JM; Killeen AA J Appl Lab Med; 2020 Jul; 5(4):695-703. PubMed ID: 32603444 [TBL] [Abstract][Full Text] [Related]
2. Comparison of Arkray/ELITech ADAMS HA-8180V with Bio-Rad Variant, II Turbo2.0 and Tosoh Bioscience HLC-723G8 for HbA1c determination. Badiou S; Guillot J; Kuster N; Bargnoux AS; Aguilar-Martinez P; Boissier E; Cristol JP; Dupuy AM J Clin Lab Anal; 2014 Nov; 28(6):428-34. PubMed ID: 24652649 [TBL] [Abstract][Full Text] [Related]
3. Analytical evaluation and quality assessment of the ARKRAY ADAMS A1c HA-8190V for Hb A1c. Urrechaga E Scand J Clin Lab Invest; 2023 Apr; 83(2):136-142. PubMed ID: 36651844 [TBL] [Abstract][Full Text] [Related]
4. Analytical evaluation of the ADAMS Urrechaga E J Clin Lab Anal; 2018 Jan; 32(1):. PubMed ID: 28236327 [TBL] [Abstract][Full Text] [Related]
5. Analytical evaluation and quality assessment of the ARKRAY ADAMS A1c Lite HA-8380V for HbA1c. Urrechaga E Scand J Clin Lab Invest; 2023 Sep; 83(5):358-365. PubMed ID: 37352386 [TBL] [Abstract][Full Text] [Related]
6. A comparative evaluation of the analytical performances of Capillarys 2 Flex Piercing, Tosoh HLC-723 G8, Premier Hb9210, and Roche Cobas c501 Tina-quant Gen 2 analyzers for HbA Wu X; Chao Y; Wan Z; Wang Y; Ma Y; Ke P; Wu X; Xu J; Zhuang J; Huang X Biochem Med (Zagreb); 2016 Oct; 26(3):353-364. PubMed ID: 27812304 [TBL] [Abstract][Full Text] [Related]
7. Evaluation of the Menarini/ARKRAY ADAMS A1c HA-8180V analyser for HbA1c. Weykamp C; Lenters-Westra E; van der Vuurst H; Slingerland R; Siebelder C; Visser-Dekkers W Clin Chem Lab Med; 2011 Apr; 49(4):647-51. PubMed ID: 21323625 [TBL] [Abstract][Full Text] [Related]
8. Effects of common hemoglobin variants on HbA1c measurements in China: results for α- and β-globin variants measured by six methods. Xu A; Chen W; Xia Y; Zhou Y; Ji L Clin Chem Lab Med; 2018 Jul; 56(8):1353-1361. PubMed ID: 29626415 [TBL] [Abstract][Full Text] [Related]
9. Evaluation of Bio-Rad D-100 HbA1c analyzer against Tosoh G8 and Menarini HA-8180V. Maesa JM; Fernández-Riejos P; Mora CS; de Toro M; Valladares PM; González-Rodriguez C Pract Lab Med; 2016 Aug; 5():57-64. PubMed ID: 28856205 [TBL] [Abstract][Full Text] [Related]
10. Evaluation of interference from 16 hemoglobin variants on hemoglobin A Yang X; Zeng X; Zhang Y; Kuang W; He D Scand J Clin Lab Invest; 2023 Feb; 83(1):18-22. PubMed ID: 36534489 [TBL] [Abstract][Full Text] [Related]
12. Two patients with α-chain hemoglobin variant Hb Q-Iran detected by measuring hemoglobin A1c using the variant mode of the HA-8180V HPLC analyzer. Kinoshita M; Shimomura D; Shimada M; Kamioka M; Koga M Diabetol Int; 2024 Apr; 15(2):302-306. PubMed ID: 38524927 [TBL] [Abstract][Full Text] [Related]
13. Multicentre evaluation of the Tosoh HbA1c G8 analyser. Chapelle JP; Teixeira J; Maisin D; Assink H; Barla G; Stroobants AK; Delzenne B; van den Eshof W Clin Chem Lab Med; 2010 Mar; 48(3):365-71. PubMed ID: 20020820 [TBL] [Abstract][Full Text] [Related]
14. Accurate and Rapid Measurement of Glycated Hemoglobin Using HLC-723 G11 Variant Mode. Park MS; Lee K; Lee K; Song J; Park HD Ann Lab Med; 2019 May; 39(3):237-244. PubMed ID: 30623615 [TBL] [Abstract][Full Text] [Related]
15. Effects of hemoglobin C, D, E and S traits on measurements of hemoglobin A1c by twelve methods. Rohlfing C; Hanson S; Weykamp C; Siebelder C; Higgins T; Molinaro R; Yip PM; Little RR Clin Chim Acta; 2016 Apr; 455():80-3. PubMed ID: 26828530 [TBL] [Abstract][Full Text] [Related]
16. Silent hemoglobin variants and determination of HbA(1c) with the high-resolution program of the HPLC HA-8160 hemoglobin analyzer. Schnedl WJ; Lahousen T; Wallner SJ; Krause R; Lipp RW Clin Biochem; 2005 Jan; 38(1):88-91. PubMed ID: 15607323 [TBL] [Abstract][Full Text] [Related]
17. Boronate Affinity Chromatography Accurately Measures HbA1c also in Patients with End-Stage Renal Disease - Performance Evaluation of the A1c HPLC Analyzer. Slowinska-Solnica K; Pawlica-Gosiewska D; Gawlik K; Kuzniewski M; Maziarz B; Solnica B Clin Lab; 2018 Sep; 64(9):1451-1455. PubMed ID: 30274022 [TBL] [Abstract][Full Text] [Related]
18. Hemoglobin S monitoring on TOSOH G8 in hemoglobin A1c mode in case of urgent red blood cell exchange. Van Aelst S; Claerhout H; Nackers E; Desmet K; Kieffer D J Clin Lab Anal; 2018 Sep; 32(7):e22453. PubMed ID: 29667731 [TBL] [Abstract][Full Text] [Related]
19. Analytical performance evaluation of hemoglobin A1c on an ARKRAY HA-8160 analyzer with newly-developed mobile phase buffer. Yu Y; Zhang X; Lin K Pract Lab Med; 2024 May; 40():e00414. PubMed ID: 38939102 [TBL] [Abstract][Full Text] [Related]
20. Application of Six Sigma Model to Evaluate the Analytical Quality of Four HbA1c Analyzers. Maesa JE; Fern Aacute Ndez-Riejos P; S Aacute Nchez-Mora C; Toro-Crespo MI; Gonz Aacute Lez-Rodriguez CO Clin Lab; 2017 Jan; 63(1):79-83. PubMed ID: 28164511 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]