177 related articles for article (PubMed ID: 32606651)
1. Differences Between Central Airway Obstruction and Chronic Obstructive Pulmonary Disease Detected with the Forced Oscillation Technique.
Yasuo M; Kitaguchi Y; Tokoro Y; Kosaka M; Wada Y; Kinjo T; Ushiki A; Yamamoto H; Hanaoka M
Int J Chron Obstruct Pulmon Dis; 2020; 15():1425-1434. PubMed ID: 32606651
[TBL] [Abstract][Full Text] [Related]
2. Usefulness of the forced oscillation technique in assessing the therapeutic result of tracheobronchial central airway obstruction.
Yasuo M; Kitaguchi Y; Kinota F; Kosaka M; Urushihata K; Ushiki A; Yamamoto H; Kawakami S; Hanaoka M
Respir Investig; 2018 May; 56(3):222-229. PubMed ID: 29773293
[TBL] [Abstract][Full Text] [Related]
3. Dynamic change in respiratory resistance during inspiratory and expiratory phases of tidal breathing in patients with chronic obstructive pulmonary disease.
Yamauchi Y; Kohyama T; Jo T; Nagase T
Int J Chron Obstruct Pulmon Dis; 2012; 7():259-69. PubMed ID: 22589578
[TBL] [Abstract][Full Text] [Related]
4. Oscillometry and pulmonary MRI measurements of ventilation heterogeneity in obstructive lung disease: relationship to quality of life and disease control.
Young HM; Guo F; Eddy RL; Maksym G; Parraga G
J Appl Physiol (1985); 2018 Jul; 125(1):73-85. PubMed ID: 29543132
[TBL] [Abstract][Full Text] [Related]
5. Impact of exacerbations on respiratory system impedance measured by a forced oscillation technique in COPD: a prospective observational study.
Kamada T; Kaneko M; Tomioka H
Int J Chron Obstruct Pulmon Dis; 2017; 12():509-516. PubMed ID: 28223791
[TBL] [Abstract][Full Text] [Related]
6. Association between respiratory impedance measured by forced oscillation technique and exacerbations in patients with COPD.
Yamagami H; Tanaka A; Kishino Y; Mikuni H; Kawahara T; Ohta S; Yamamoto M; Suzuki S; Ohnishi T; Sagara H
Int J Chron Obstruct Pulmon Dis; 2018; 13():79-89. PubMed ID: 29317813
[TBL] [Abstract][Full Text] [Related]
7. Accuracy of forced oscillation technique to assess lung function in geriatric COPD population.
Tse HN; Tseng CZ; Wong KY; Yee KS; Ng LY
Int J Chron Obstruct Pulmon Dis; 2016; 11():1105-18. PubMed ID: 27307726
[TBL] [Abstract][Full Text] [Related]
8. Novel Respiratory Impedance-Based Phenotypes Reflect Different Pathophysiologies in Chronic Obstructive Pulmonary Disease Patients.
Matsuo Y; Ogawa E; Seto-Yukimura R; Ryujin Y; Kinose D; Yamaguchi M; Osawa M; Nagao T; Kurosawa H; Nakano Y
Int J Chron Obstruct Pulmon Dis; 2019; 14():2971-2977. PubMed ID: 31908445
[TBL] [Abstract][Full Text] [Related]
9. Relationships Between Forced Oscillatory Impedance and 6-minute Walk Distance After Pulmonary Rehabilitation in COPD.
Zimmermann SC; Thamrin C; Chan AS; Bertolin A; Chapman DG; King GG
Int J Chron Obstruct Pulmon Dis; 2020; 15():157-166. PubMed ID: 32021155
[TBL] [Abstract][Full Text] [Related]
10. [The forced oscillation technique in the functional evaluation of COPD dyspnea].
Ghilain A; Marchand E
Rev Mal Respir; 2022 Oct; 39(8):659-668. PubMed ID: 36041937
[TBL] [Abstract][Full Text] [Related]
11. Diversity of respiratory impedance based on quantitative computed tomography in patients with COPD.
Wada Y; Kitaguchi Y; Yasuo M; Ueno F; Kawakami S; Fukushima K; Fujimoto K; Hanaoka M
Int J Chron Obstruct Pulmon Dis; 2018; 13():1841-1849. PubMed ID: 29892193
[TBL] [Abstract][Full Text] [Related]
12. Changes in respiratory mechanics with increasing degrees of airway obstruction in COPD: detection by forced oscillation technique.
Di Mango AM; Lopes AJ; Jansen JM; Melo PL
Respir Med; 2006 Mar; 100(3):399-410. PubMed ID: 16115754
[TBL] [Abstract][Full Text] [Related]
13. Respiratory system reactance reflects communicating lung volume in chronic obstructive pulmonary disease.
Milne S; Jetmalani K; Chapman DG; Duncan JM; Farah CS; Thamrin C; King GG
J Appl Physiol (1985); 2019 May; 126(5):1223-1231. PubMed ID: 30763164
[TBL] [Abstract][Full Text] [Related]
14. Comparison of impedance measured by the forced oscillation technique and pulmonary functions, including static lung compliance, in obstructive and interstitial lung disease.
Takeichi N; Yamazaki H; Fujimoto K
Int J Chron Obstruct Pulmon Dis; 2019; 14():1109-1118. PubMed ID: 31213791
[No Abstract] [Full Text] [Related]
15. Forced oscillation technique for early detection of the effects of smoking and COPD: contribution of fractional-order modeling.
Ribeiro CO; Faria ACD; Lopes AJ; de Melo PL
Int J Chron Obstruct Pulmon Dis; 2018; 13():3281-3295. PubMed ID: 30349233
[TBL] [Abstract][Full Text] [Related]
16. Effect of increasing respiratory rate on airway resistance and reactance in COPD patients.
Nakagawa M; Hattori N; Haruta Y; Sugiyama A; Iwamoto H; Ishikawa N; Fujitaka K; Murai H; Tanaka J; Kohno N
Respirology; 2015 Jan; 20(1):87-94. PubMed ID: 25251948
[TBL] [Abstract][Full Text] [Related]
17. Respiratory mechanics measured by forced oscillation technique in combined pulmonary fibrosis and emphysema.
Mori K; Shirai T; Mikamo M; Shishido Y; Akita T; Morita S; Asada K; Fujii M; Hozumi H; Suda T; Chida K
Respir Physiol Neurobiol; 2013 Jan; 185(2):235-40. PubMed ID: 23117106
[TBL] [Abstract][Full Text] [Related]
18. Home monitoring of within-breath respiratory mechanics by a simple and automatic forced oscillation technique device.
Dellacà RL; Gobbi A; Pastena M; Pedotti A; Celli B
Physiol Meas; 2010 Apr; 31(4):N11-24. PubMed ID: 20182000
[TBL] [Abstract][Full Text] [Related]
19. Window of opportunity for respiratory oscillometry: A review of recent research.
Kostorz-Nosal S; Jastrzębski D; Błach A; Skoczyński S
Respir Physiol Neurobiol; 2023 Oct; 316():104135. PubMed ID: 37536553
[TBL] [Abstract][Full Text] [Related]
20. Relationships between respiratory and airway resistances and activity-related dyspnea in patients with chronic obstructive pulmonary disease.
Mahut B; Caumont-Prim A; Plantier L; Gillet-Juvin K; Callens E; Sanchez O; Chevalier-Bidaud B; Bokov P; Delclaux C
Int J Chron Obstruct Pulmon Dis; 2012; 7():165-71. PubMed ID: 22500118
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]