These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

537 related articles for article (PubMed ID: 32608033)

  • 1. THE IMS PARADOX: A PERSPECTIVE ON STRUCTURAL ION MOBILITY-MASS SPECTROMETRY.
    McCabe JW; Hebert MJ; Shirzadeh M; Mallis CS; Denton JK; Walker TE; Russell DH
    Mass Spectrom Rev; 2021 May; 40(3):280-305. PubMed ID: 32608033
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Fourier Transform-Ion Mobility-Orbitrap Mass Spectrometer: A Next-Generation Instrument for Native Mass Spectrometry.
    Poltash ML; McCabe JW; Shirzadeh M; Laganowsky A; Clowers BH; Russell DH
    Anal Chem; 2018 Sep; 90(17):10472-10478. PubMed ID: 30091588
    [TBL] [Abstract][Full Text] [Related]  

  • 3. T-wave ion mobility-mass spectrometry: basic experimental procedures for protein complex analysis.
    Michaelevski I; Kirshenbaum N; Sharon M
    J Vis Exp; 2010 Jul; (41):. PubMed ID: 20729801
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effects of drift gas on collision cross sections of a protein standard in linear drift tube and traveling wave ion mobility mass spectrometry.
    Jurneczko E; Kalapothakis J; Campuzano ID; Morris M; Barran PE
    Anal Chem; 2012 Oct; 84(20):8524-31. PubMed ID: 22974196
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Native IM-Orbitrap MS: Resolving What Was Hidden.
    Poltash ML; McCabe JW; Shirzadeh M; Laganowsky A; Russell DH
    Trends Analyt Chem; 2020 Mar; 124():. PubMed ID: 32189816
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Deciphering drift time measurements from travelling wave ion mobility spectrometry-mass spectrometry studies.
    Smith DP; Knapman TW; Campuzano I; Malham RW; Berryman JT; Radford SE; Ashcroft AE
    Eur J Mass Spectrom (Chichester); 2009; 15(2):113-30. PubMed ID: 19423898
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Conditions for Analysis of Native Protein Structures Using Uniform Field Drift Tube Ion Mobility Mass Spectrometry and Characterization of Stable Calibrants for TWIM-MS.
    Harrison JA; Kelso C; Pukala TL; Beck JL
    J Am Soc Mass Spectrom; 2019 Feb; 30(2):256-267. PubMed ID: 30324262
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cryogenic Ion Mobility-Mass Spectrometry: Tracking Ion Structure from Solution to the Gas Phase.
    Servage KA; Silveira JA; Fort KL; Russell DH
    Acc Chem Res; 2016 Jul; 49(7):1421-8. PubMed ID: 27334393
    [TBL] [Abstract][Full Text] [Related]  

  • 9. New High Resolution Ion Mobility Mass Spectrometer Capable of Measurements of Collision Cross Sections from 150 to 520 K.
    Ujma J; Giles K; Morris M; Barran PE
    Anal Chem; 2016 Oct; 88(19):9469-9478. PubMed ID: 27573618
    [TBL] [Abstract][Full Text] [Related]  

  • 10. First-Principles Collision Cross Section Measurements of Large Proteins and Protein Complexes.
    McCabe JW; Mallis CS; Kocurek KI; Poltash ML; Shirzadeh M; Hebert MJ; Fan L; Walker TE; Zheng X; Jiang T; Dong S; Lin CW; Laganowsky A; Russell DH
    Anal Chem; 2020 Aug; 92(16):11155-11163. PubMed ID: 32662991
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Surface induced dissociation: dissecting noncovalent protein complexes in the gas phase.
    Zhou M; Wysocki VH
    Acc Chem Res; 2014 Apr; 47(4):1010-8. PubMed ID: 24524650
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Separation and Collision Cross Section Measurements of Protein Complexes Afforded by a Modular Drift Tube Coupled to an Orbitrap Mass Spectrometer.
    Sipe SN; Sanders JD; Reinecke T; Clowers BH; Brodbelt JS
    Anal Chem; 2022 Jul; 94(26):9434-9441. PubMed ID: 35736993
    [TBL] [Abstract][Full Text] [Related]  

  • 13. High-resolution ion mobility based on traveling wave structures for lossless ion manipulation resolves hidden lipid features.
    Reardon AR; May JC; Leaptrot KL; McLean JA
    Anal Bioanal Chem; 2024 Oct; 416(25):5473-5483. PubMed ID: 38935144
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Partially disordered proteins studied by ion mobility-mass spectrometry: implications for the preservation of solution phase structure in the gas phase.
    Vahidi S; Stocks BB; Konermann L
    Anal Chem; 2013 Nov; 85(21):10471-8. PubMed ID: 24088086
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of gaseous ubiquitin ion structures obtained from a solid and solution matrix using ion mobility spectrometry/mass spectrometry.
    Inutan ED; Jarois DR; Lietz CB; El-Baba TJ; Elia EA; Karki S; Sampat AAS; Foley CD; Clemmer DE; Trimpin S
    Rapid Commun Mass Spectrom; 2021 Jan; 35 Suppl 1():e8793. PubMed ID: 32220130
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Elucidating the Gas-Phase Behavior of Nitazene Analog Protomers Using Structures for Lossless Ion Manipulations Ion Mobility-Orbitrap Mass Spectrometry.
    Hollerbach AL; Lin VS; Ibrahim YM; Ewing RG; Metz TO; Rodda KE
    J Am Soc Mass Spectrom; 2024 Jul; 35(7):1609-1621. PubMed ID: 38907730
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accurate Collisional Cross Section Measurement by Multipass Cyclic Ion Mobility Spectrometry.
    Xia C; Mernie E; Zaia J; Costello CE; Lin C
    Anal Chem; 2024 Jul; 96(29):11959-11968. PubMed ID: 38990519
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Structure Relaxation Approximation (SRA) for Elucidation of Protein Structures from Ion Mobility Measurements (II). Protein Complexes.
    Cropley TC; Liu FC; Pedrete T; Hossain MA; Agar JN; Bleiholder C
    J Phys Chem B; 2023 Jun; 127(25):5553-5565. PubMed ID: 37311097
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Structurally selective imaging mass spectrometry by imaging ion mobility-mass spectrometry.
    McLean JA; Fenn LS; Enders JR
    Methods Mol Biol; 2010; 656():363-83. PubMed ID: 20680602
    [TBL] [Abstract][Full Text] [Related]  

  • 20. How useful is ion mobility mass spectrometry for structural biology? The relationship between protein crystal structures and their collision cross sections in the gas phase.
    Jurneczko E; Barran PE
    Analyst; 2011 Jan; 136(1):20-8. PubMed ID: 20820495
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 27.