These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

291 related articles for article (PubMed ID: 32620297)

  • 1. Similar Risk of Revision After Kinematically Aligned, Patient-Specific Instrumented Total Knee Arthroplasty, and All Other Total Knee Arthroplasty: Combined Results From the Australian and New Zealand Joint Replacement Registries.
    Klasan A; de Steiger R; Holland S; Hatton A; Vertullo CJ; Young SW
    J Arthroplasty; 2020 Oct; 35(10):2872-2877. PubMed ID: 32620297
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Decreased Survival of Medial Pivot Designs Compared with Cruciate-retaining Designs in TKA Without Patellar Resurfacing.
    Øhrn FD; Gøthesen Ø; Låstad Lygre SH; Peng Y; Lian ØB; Lewis PL; Furnes O; Röhrl SM
    Clin Orthop Relat Res; 2020 Jun; 478(6):1207-1218. PubMed ID: 31977446
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A randomized controlled trial of tibial component migration with kinematic alignment using patient-specific instrumentation versus mechanical alignment using computer-assisted surgery in total knee arthroplasty.
    Laende EK; Richardson CG; Dunbar MJ
    Bone Joint J; 2019 Aug; 101-B(8):929-940. PubMed ID: 31362561
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Short-term follow-up of kinematically vs. mechanically aligned total knee arthroplasty with medial pivot components: A case-control study.
    Jeremić DV; Massouh WM; Sivaloganathan S; Rosali AR; Haaker RG; Rivière C
    Orthop Traumatol Surg Res; 2020 Sep; 106(5):921-927. PubMed ID: 32522532
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Does Knee Prosthesis Survivorship Improve When Implant Designs Change? Findings from the Australian Orthopaedic Association National Joint Replacement Registry.
    Lewis PL; Graves SE; de Steiger RN; Campbell DG; Peng Y; Hatton A; Lorimer M
    Clin Orthop Relat Res; 2020 Jun; 478(6):1156-1172. PubMed ID: 32324669
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Impact of Image-Derived Instrumentation on Total Knee Arthroplasty Revision Rates: An Analysis of 83,823 Procedures from the Australian Orthopaedic Association National Joint Replacement Registry.
    McAuliffe MJ; Beer BR; Hatch JJ; Crawford RW; Cuthbert AR; Donnelly WJ
    J Bone Joint Surg Am; 2019 Apr; 101(7):580-588. PubMed ID: 30946191
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Outcome of kinematic alignment using patient-specific instrumentation versus mechanical alignment in TKA: a meta-analysis and subgroup analysis of randomised trials.
    Woon JTK; Zeng ISL; Calliess T; Windhagen H; Ettinger M; Waterson HB; Toms AD; Young SW
    Arch Orthop Trauma Surg; 2018 Sep; 138(9):1293-1303. PubMed ID: 29961093
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Kinematically aligned total knee arthroplasty reduces knee adduction moment more than mechanically aligned total knee arthroplasty.
    Niki Y; Nagura T; Nagai K; Kobayashi S; Harato K
    Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1629-1635. PubMed ID: 29204861
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Total knee arthroplasty according to the original knee phenotypes with kinematic alignment surgical technique-early clinical and functional outcomes.
    Hsu CE; Huang JT; Tong KM; Huang KC
    BMC Musculoskelet Disord; 2020 Dec; 21(1):839. PubMed ID: 33308196
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Kinematic alignment is bone and soft tissue preserving compared to mechanical alignment in total knee arthroplasty.
    An VVG; Twiggs J; Leie M; Fritsch BA
    Knee; 2019 Mar; 26(2):466-476. PubMed ID: 30772187
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Kinematic alignment is a possible alternative to mechanical alignment in total knee arthroplasty.
    Lee YS; Howell SM; Won YY; Lee OS; Lee SH; Vahedi H; Teo SH
    Knee Surg Sports Traumatol Arthrosc; 2017 Nov; 25(11):3467-3479. PubMed ID: 28439636
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Kinematically aligned total knee arthroplasty restores more native medial collateral ligament strain than mechanically aligned total knee arthroplasty.
    Lim D; Kwak DS; Kim M; Kim S; Cho HJ; Choi JH; Koh IJ
    Knee Surg Sports Traumatol Arthrosc; 2022 Aug; 30(8):2815-2823. PubMed ID: 34312712
    [TBL] [Abstract][Full Text] [Related]  

  • 13. What Is the Risk of Repeat Revision When Patellofemoral Replacement Is Revised to TKA? An Analysis of 482 Cases From a Large National Arthroplasty Registry.
    Lewis PL; Graves SE; Cuthbert A; Parker D; Myers P
    Clin Orthop Relat Res; 2019 Jun; 477(6):1402-1410. PubMed ID: 31136442
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Restoring the constitutional alignment with a restrictive kinematic protocol improves quantitative soft-tissue balance in total knee arthroplasty: a randomized controlled trial.
    MacDessi SJ; Griffiths-Jones W; Chen DB; Griffiths-Jones S; Wood JA; Diwan AD; Harris IA
    Bone Joint J; 2020 Jan; 102-B(1):117-124. PubMed ID: 31888372
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Does varus alignment adversely affect implant survival and function six years after kinematically aligned total knee arthroplasty?
    Howell SM; Papadopoulos S; Kuznik K; Ghaly LR; Hull ML
    Int Orthop; 2015 Nov; 39(11):2117-24. PubMed ID: 25823516
    [TBL] [Abstract][Full Text] [Related]  

  • 16. What Is the Long-term Survivorship of Cruciate-retaining TKA in the Finnish Registry?
    Montonen E; Laaksonen I; Matilainen M; Eskelinen A; Haapakoski J; Puhto AP; Leskinen J; Kettunen J; Manninen M; Mäkelä KT
    Clin Orthop Relat Res; 2018 Jun; 476(6):1205-1211. PubMed ID: 29406454
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Lower prosthesis-specific 10-year revision rate with crosslinked than with non-crosslinked polyethylene in primary total knee arthroplasty.
    de Steiger RN; Muratoglu O; Lorimer M; Cuthbert AR; Graves SE
    Acta Orthop; 2015; 86(6):721-7. PubMed ID: 26119884
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The three-year survivorship of robotically assisted versus non-robotically assisted unicompartmental knee arthroplasty.
    St Mart JP; de Steiger RN; Cuthbert A; Donnelly W
    Bone Joint J; 2020 Mar; 102-B(3):319-328. PubMed ID: 32114810
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Joint Line Modification in Kinematically Aligned Total Knee Arthroplasty Improves Functional Activity but Not Patient Satisfaction.
    Niki Y; Kobayashi S; Nagura T; Udagawa K; Harato K
    J Arthroplasty; 2018 Jul; 33(7):2125-2130. PubMed ID: 29506930
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Robotic-assisted surgery and kinematic alignment in total knee arthroplasty (RASKAL study): a protocol of a national registry-nested, multicentre, 2×2 factorial randomised trial assessing clinical, intraoperative, functional, radiographic and survivorship outcomes.
    MacDessi SJ; Wernecke GC; Bastiras D; Hooper T; Heath E; Lorimer M; Harris I;
    BMJ Open; 2022 Jun; 12(6):e051088. PubMed ID: 35688590
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.