253 related articles for article (PubMed ID: 32620852)
1. Impact of quantitative pulmonary emphysema score on the rate of pneumothorax and chest tube insertion in CT-guided lung biopsies.
Theilig D; Petschelt D; Mayerhofer A; Hamm B; Gebauer B; Geisel D
Sci Rep; 2020 Jul; 10(1):10978. PubMed ID: 32620852
[TBL] [Abstract][Full Text] [Related]
2. Efficacy of the tract embolization technique with gelatin sponge slurry to reduce pneumothorax and chest tube placement after percutaneous CT-guided lung biopsy.
Renier H; Gérard L; Lamborelle P; Cousin F
Cardiovasc Intervent Radiol; 2020 Apr; 43(4):597-603. PubMed ID: 31792589
[TBL] [Abstract][Full Text] [Related]
3. Pneumothorax after CT-guided transthoracic lung biopsy: A comparison between immediate and delayed occurrence.
Bae K; Ha JY; Jeon KN
PLoS One; 2020; 15(8):e0238107. PubMed ID: 32834016
[TBL] [Abstract][Full Text] [Related]
4. Predictors of pneumothorax and chest drainage after percutaneous CT-guided lung biopsy: A prospective study.
Ruud EA; Stavem K; Geitung JT; Borthne A; Søyseth V; Ashraf H
Eur Radiol; 2021 Jun; 31(6):4243-4252. PubMed ID: 33354745
[TBL] [Abstract][Full Text] [Related]
5. Pneumothorax Complicating Coaxial and Non-coaxial CT-Guided Lung Biopsy: Comparative Analysis of Determining Risk Factors and Management of Pneumothorax in a Retrospective Review of 650 Patients.
Nour-Eldin NE; Alsubhi M; Emam A; Lehnert T; Beeres M; Jacobi V; Gruber-Rouh T; Scholtz JE; Vogl TJ; Naguib NN
Cardiovasc Intervent Radiol; 2016 Feb; 39(2):261-70. PubMed ID: 26148648
[TBL] [Abstract][Full Text] [Related]
6. Risk factors influencing chest tube placement among patients with pneumothorax because of CT-guided needle biopsy of the lung.
Nakamura M; Yoshizako T; Koyama S; Kitagaki H
J Med Imaging Radiat Oncol; 2011 Oct; 55(5):474-8. PubMed ID: 22008165
[TBL] [Abstract][Full Text] [Related]
7. Pneumothorax with prolonged chest tube requirement after CT-guided percutaneous lung biopsy: incidence and risk factors.
Moreland A; Novogrodsky E; Brody L; Durack J; Erinjeri J; Getrajdman G; Solomon S; Yarmohammadi H; Maybody M
Eur Radiol; 2016 Oct; 26(10):3483-91. PubMed ID: 26787605
[TBL] [Abstract][Full Text] [Related]
8. The Effect of Needle Gauge on the Risk of Pneumothorax and Chest Tube Placement After Percutaneous Computed Tomographic (CT)-Guided Lung Biopsy.
Kuban JD; Tam AL; Huang SY; Ensor JE; Philip AS; Chen GJ; Ahrar J; Murthy R; Avritscher R; Madoff DC; Mahvash A; Ahrar K; Wallace MJ; Nachiappan AC; Gupta S
Cardiovasc Intervent Radiol; 2015 Dec; 38(6):1595-602. PubMed ID: 25920917
[TBL] [Abstract][Full Text] [Related]
9. Pneumothorax Incidence with Normal Saline Instillation for Sealing the Needle Track After Computed Tomography-Guided Percutaneous Lung Biopsy.
Bourgeais G; Frampas E; Liberge R; Nicolas A; Defrance C; Blanc FX; Coudol S; Morla O
Cardiovasc Intervent Radiol; 2024 May; 47(5):604-612. PubMed ID: 38263525
[TBL] [Abstract][Full Text] [Related]
10. Dependent lesion positioning at CT-guided lung biopsy to reduce risk of pneumothorax.
Appel E; Dommaraju S; Camacho A; Nakhaei M; Siewert B; Ahmed M; Brook A; Brook OR
Eur Radiol; 2020 Nov; 30(11):6369-6375. PubMed ID: 32591892
[TBL] [Abstract][Full Text] [Related]
11. Pneumothorax Rate and Diagnostic Adequacy of Computed Tomography-guided Lung Nodule Biopsies Performed With 18 G Versus 20 G Needles: A Cross-Sectional Study.
Kolderman NC; Cheti DR; Hasbrook CD; Forsyth AJ; Coffey MP; Nair GB; Al-Katib SA
J Thorac Imaging; 2020 Jul; 35(4):265-269. PubMed ID: 32032253
[TBL] [Abstract][Full Text] [Related]
12. Predictors of pneumothorax after CT-guided transthoracic needle lung biopsy: the role of quantitative CT.
Chami HA; Faraj W; Yehia ZA; Badour SA; Sawan P; Rebeiz K; Safa R; Saade C; Ghandour B; Shamseddine A; Mukherji D; Haydar AA
Clin Radiol; 2015 Dec; 70(12):1382-7. PubMed ID: 26392317
[TBL] [Abstract][Full Text] [Related]
13. Perilesional emphysema as a predictor of risk of complications from computed tomography-guided transthoracic lung biopsy.
Lee DS; Bak SH; Jeon YH; Kwon SO; Kim WJ
Jpn J Radiol; 2019 Dec; 37(12):808-816. PubMed ID: 31541398
[TBL] [Abstract][Full Text] [Related]
14. Pneumothoraces and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique: incidence and risk factors.
Laurent F; Michel P; Latrabe V; Tunon de Lara M; Marthan R
AJR Am J Roentgenol; 1999 Apr; 172(4):1049-53. PubMed ID: 10587145
[TBL] [Abstract][Full Text] [Related]
15. Risk Factors for Pneumothorax Development Following CT-Guided Core Lung Nodule Biopsy.
Sargent T; Kolderman N; Nair GB; Jankowski M; Al-Katib S
J Bronchology Interv Pulmonol; 2022 Jul; 29(3):198-205. PubMed ID: 34654044
[TBL] [Abstract][Full Text] [Related]
16. Complications of CT-guided lung biopsy with a non-coaxial semi-automated 18 gauge biopsy system: Frequency, severity and risk factors.
Elshafee AS; Karch A; Ringe KI; Shin HO; Raatschen HJ; Soliman NY; Wacker F; Vogel-Claussen J
PLoS One; 2019; 14(3):e0213990. PubMed ID: 30883575
[TBL] [Abstract][Full Text] [Related]
17. CT-guided Lung Biopsy: Effect of Biopsy-side Down Position on Pneumothorax and Chest Tube Placement.
Drumm O; Joyce EA; de Blacam C; Gleeson T; Kavanagh J; McCarthy E; McDermott R; Beddy P
Radiology; 2019 Jul; 292(1):190-196. PubMed ID: 31084480
[TBL] [Abstract][Full Text] [Related]
18. CT-guided transthoracic needle aspiration biopsy of small (< or = 20 mm) solitary pulmonary nodules.
Ohno Y; Hatabu H; Takenaka D; Higashino T; Watanabe H; Ohbayashi C; Sugimura K
AJR Am J Roentgenol; 2003 Jun; 180(6):1665-9. PubMed ID: 12760939
[TBL] [Abstract][Full Text] [Related]
19. Pneumothorax after computed tomography-guided lung biopsy: Utility of immediate post-procedure computed tomography and one-hour delayed chest radiography.
Weinand JT; du Pisanie L; Ngeve S; Commander C; Yu H
PLoS One; 2023; 18(4):e0284145. PubMed ID: 37075048
[TBL] [Abstract][Full Text] [Related]
20. Combined autologous blood patch-immediate patient rollover does not reduce the pneumothorax or chest drain rate following CT-guided lung biopsy compared to immediate patient rollover alone.
Duignan JA; Ryan DT; O'Riordan B; O'Brien A; Healy GM; O'Brien C; Butler M; Keane MP; McCarthy C; Murphy DJ; Dodd JD
Eur J Radiol; 2023 Mar; 160():110691. PubMed ID: 36640713
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]