These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

758 related articles for article (PubMed ID: 32621212)

  • 21. Pulmonary vein reconnection following catheter ablation of atrial fibrillation using the second-generation cryoballoon versus open-irrigated radiofrequency: results of a multicenter analysis.
    Aryana A; Singh SM; Mugnai G; de Asmundis C; Kowalski M; Pujara DK; Cohen AI; Singh SK; Fuenzalida CE; Prager N; Bowers MR; O'Neill PG; Brugada P; d'Avila A; Chierchia GB
    J Interv Card Electrophysiol; 2016 Dec; 47(3):341-348. PubMed ID: 27475949
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Pulmonary vein isolation with real-time pulmonary vein potential recording using second-generation cryoballoon: Procedural and biophysical predictors of acute pulmonary vein reconnection.
    Wei HQ; Guo XG; Zhou GB; Sun Q; Liu X; Yang JD; Luo B; Ma J
    Pacing Clin Electrophysiol; 2018 Jan; 41(1):14-21. PubMed ID: 29087000
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Pulmonary vein reconnection and repeat ablation characteristics following cryoballoon-compared to radiofrequency-based pulmonary vein isolation.
    Obergassel J; Nies M; Taraba S; Rottner L; Lemoine MD; My I; Moser F; Rieß JL; Schenker N; Dinshaw L; Schleberger R; Reißmann B; Meyer C; Willems S; Rillig A; Kirchhof P; Metzner A
    J Cardiovasc Electrophysiol; 2024 Sep; 35(9):1766-1778. PubMed ID: 38956821
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Relationship between atrial scar on cardiac magnetic resonance and pulmonary vein reconnection after catheter ablation for paroxysmal atrial fibrillation.
    Jefairi NA; Camaioni C; Sridi S; Cheniti G; Takigawa M; Nivet H; Denis A; Derval N; Mathilde Merle ; Laurent F; Montaudon M; Sacher F; Hocini M; Haissaguerre M; Jais P; Cochet H
    J Cardiovasc Electrophysiol; 2019 May; 30(5):727-740. PubMed ID: 30847990
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Cryoballoon temperature parameters during cryoballoon ablation predict pulmonary vein reconnection and atrial fibrillation recurrence.
    Chahine Y; Afroze T; Bifulco SF; Macheret F; Abdulsalam N; Boyle PM; Akoum N
    J Interv Card Electrophysiol; 2023 Sep; 66(6):1367-1373. PubMed ID: 36418664
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Additional cryoapplications at the pulmonary vein antrum using a 28-mm second-generation cryoballoon: a pilot study of extra-pulmonary vein ablation.
    Miyazaki S; Kajiyama T; Watanabe T; Ichijo S; Iesaka Y
    Heart Vessels; 2018 Sep; 33(9):1052-1059. PubMed ID: 29464341
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Balloon warming time is the strongest predictor of late pulmonary vein electrical reconnection following cryoballoon ablation for atrial fibrillation.
    Ghosh J; Martin A; Keech AC; Chan KH; Gomes S; Singarayar S; McGuire MA
    Heart Rhythm; 2013 Sep; 10(9):1311-7. PubMed ID: 23792110
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Value of high-resolution mapping in optimizing cryoballoon ablation of atrial fibrillation.
    Conte G; Soejima K; de Asmundis C; Chierchia GB; Badini M; Miwa Y; Caputo ML; Özkartal T; Maffessanti F; Sieira J; Degreef Y; Stroker E; Regoli F; Moccetti T; Brugada P; Auricchio A
    Int J Cardiol; 2018 Nov; 270():136-142. PubMed ID: 29929934
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The absence of real-time pulmonary vein isolation during cryoballoon ablation is associated with atrial fibrillation recurrence and pulmonary vein reconnection : Insights from the Middelheim-PVI Registry 2.
    De Greef Y; Sofianos D; Tijskens M; Schwagten B; Wolf M; Buysschaert I; Abugattas JP
    J Interv Card Electrophysiol; 2023 Dec; 66(9):2091-2101. PubMed ID: 37067765
    [TBL] [Abstract][Full Text] [Related]  

  • 30. On the Quest for the Best Freeze: Predictors of Late Pulmonary Vein Reconnections After Second-Generation Cryoballoon Ablation.
    Ciconte G; Mugnai G; Sieira J; Velagić V; Saitoh Y; Irfan G; Hunuk B; Ströker E; Conte G; Di Giovanni G; Baltogiannis G; Wauters K; Brugada P; de Asmundis C; Chierchia GB
    Circ Arrhythm Electrophysiol; 2015 Dec; 8(6):1359-65. PubMed ID: 26527624
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Less Pulmonary Vein Reconnection at Redo Procedures Following Radiofrequency Point-by-Point Antral Pulmonary Vein Isolation With the Use of Contemporary Catheter Ablation Technologies.
    Sandorfi G; Rodriguez-Mañero M; Saenen J; Baluja A; Bories W; Huybrechts W; Miljoen H; Vandaele L; Heidbuchel H; Sarkozy A
    JACC Clin Electrophysiol; 2018 Dec; 4(12):1556-1565. PubMed ID: 30573119
    [TBL] [Abstract][Full Text] [Related]  

  • 32. One-year clinical success of a 'no-bonus' freeze protocol using the second-generation 28 mm cryoballoon for pulmonary vein isolation.
    Wissner E; Heeger CH; Grahn H; Reissmann B; Wohlmuth P; Lemes C; Rausch P; Mathew S; Rillig A; Deiss S; Maurer T; Lin T; Tilz RR; Ouyang F; Kuck KH; Metzner A
    Europace; 2015 Aug; 17(8):1236-40. PubMed ID: 25868468
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Repeat catheter ablation for recurrent atrial fibrillation: Electrophysiologic findings and clinical outcomes.
    Daimee UA; Akhtar T; Boyle TA; Jager L; Arbab-Zadeh A; Marine JE; Berger RD; Calkins H; Spragg DD
    J Cardiovasc Electrophysiol; 2021 Mar; 32(3):628-638. PubMed ID: 33410561
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Dissociated pulmonary vein activity after pulmonary vein isolation for paroxysmal atrial fibrillation: a predictor for recurrence?
    Buiatti A; Ammar S; Reents T; Semmler V; Kathan S; Hofmann M; Bourier F; Telishevska M; Koch-Büttner K; Kaess B; Lennerz C; Kolb C; Hessling G; Deisenhofer I
    J Cardiovasc Electrophysiol; 2015 Jan; 26(1):7-13. PubMed ID: 25091566
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The mechanisms of recurrent atrial arrhythmias after second-generation cryoballoon ablation.
    Miyazaki S; Horie T; Hachiya H; Hasegawa K; Kajiyama T; Watanabe T; Nakamura H; Ishikawa E; Mukai M; Aoyama D; Nodera M; Kaseno K; Iesaka Y; Tada H
    Am Heart J; 2020 Mar; 221():29-38. PubMed ID: 31901798
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison of advanced generation cryoballoon ablation and ablation index-guided pulmonary vein isolation with non-pulmonary vein trigger induction test and additional ablation in paroxysmal atrial fibrillation.
    Egami Y; Nishino M; Nohara H; Kawanami S; Sugae H; Ukita K; Kawamura A; Nakamura H; Yasumoto K; Tsuda M; Okamoto N; Matsunaga-Lee Y; Yano M; Tanouchi J
    J Interv Card Electrophysiol; 2023 Oct; 66(7):1571-1580. PubMed ID: 36575227
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Repeat pulmonary vein isolation with or without FIRM-guided ablation for recurrent atrial fibrillation with pulmonary vein reconnection.
    Peigh G; Wasserlauf J; Kaplan RM; Amaral AP; Trivedi A; Chicos AB; Arora R; Kim S; Lin A; Verma N; Knight BP; Passman RS
    J Cardiovasc Electrophysiol; 2020 May; 31(5):1031-1037. PubMed ID: 32115794
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Durability of CLOSE-Guided Pulmonary Vein Isolation in Persistent Atrial Fibrillation: A Prospective Remapping Study.
    Galuszka OM; Baldinger SH; Servatius H; Seiler J; Madaffari A; Kozhuharov N; Thalmann G; Kueffer T; Muehl A; Maurhofer J; Haeberlin A; Noti F; Tanner H; Reichlin T; Roten L
    JACC Clin Electrophysiol; 2024 Jun; 10(6):1090-1100. PubMed ID: 38639700
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Adenosine testing during cryoballoon ablation and radiofrequency ablation of atrial fibrillation: A propensity score-matched analysis.
    Tokuda M; Matsuo S; Isogai R; Uno G; Tokutake K; Yokoyama K; Kato M; Narui R; Tanigawa S; Yamashita S; Inada K; Yoshimura M; Yamane T
    Heart Rhythm; 2016 Nov; 13(11):2128-2134. PubMed ID: 27520540
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Characterization of Electrical Reconnection Following Pulmonary Vein Isolation Using First- and Second-Generation Cryoballoon.
    Koektuerk B; Yorgun H; Koektuerk O; Turan CH; Keskin K; Schoett M; Turan RG; Gorr E; Hoppe C; Horlitz M
    Pacing Clin Electrophysiol; 2016 May; 39(5):434-42. PubMed ID: 26910475
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 38.