These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 32630875)

  • 21. Measurement errors resulted from misalignment errors of the retarder in a rotating-retarder complete Stokes polarimeter.
    Dai H; Yan C
    Opt Express; 2014 May; 22(10):11869-83. PubMed ID: 24921308
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Retardance and flicker modeling and characterization of electro-optic linear retarders by averaged Stokes polarimetry.
    Martínez FJ; Márquez A; Gallego S; Francés J; Pascual I; Beléndez A
    Opt Lett; 2014 Feb; 39(4):1011-4. PubMed ID: 24562265
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Characterization of retardance spatial variations over the aperture of liquid-crystal variable retarders.
    Ramírez CN; Montes-González I; Bruce NC; López-Téllez JM; Rodríguez-Herrera OG; Rosete-Aguilar M
    Appl Opt; 2021 Apr; 60(11):2998-3005. PubMed ID: 33983193
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Interpolation strategies for reducing IFOV artifacts in microgrid polarimeter imagery.
    Ratliff BM; LaCasse CF; Tyo JS
    Opt Express; 2009 May; 17(11):9112-25. PubMed ID: 19466161
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Precision of retardance autocalibration in full-Stokes division-of-focal-plane imaging polarimeters: publisher's note.
    Goudail F; Li X; Boffety M; Roussel S; Liu T; Hu H
    Opt Lett; 2019 Dec; 44(23):5759. PubMed ID: 31774772
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Using Zodiacal Light For Spaceborne Calibration Of Polarimetric Imagers.
    Avitan O; Schechner YY; Behar E
    IEEE Trans Pattern Anal Mach Intell; 2023 Jul; PP():. PubMed ID: 37498755
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Optimizing imaging polarimeters constructed with imperfect optics.
    Tyo JS; Wei H
    Appl Opt; 2006 Aug; 45(22):5497-503. PubMed ID: 16855648
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Noise equalization in Stokes parameter images obtained by use of variable-retardance polarimeters.
    Tyo JS
    Opt Lett; 2000 Aug; 25(16):1198-200. PubMed ID: 18066166
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Achromatic athermalized retarder fabrication.
    Mahler AB; McClain S; Chipman R
    Appl Opt; 2011 Feb; 50(5):755-65. PubMed ID: 21343998
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Stokes polarimetry using analysis of the nonlinear voltage-retardance relationship for liquid-crystal variable retarders.
    López-Téllez JM; Bruce NC
    Rev Sci Instrum; 2014 Mar; 85(3):033104. PubMed ID: 24689561
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Calibration method using a single retarder to simultaneously measure polarization and fully characterize a polarimeter over a broad range of wavelengths.
    Romerein MJ; Philippson JN; Brooks RL; Shiell RC
    Appl Opt; 2011 Oct; 50(28):5382-9. PubMed ID: 22016204
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Colorimetric discrimination for Stokes polarimetric imaging.
    Yu M; Huang H; Hu H; Wu L; Zhai H; Liu T
    Opt Express; 2017 Feb; 25(4):3765-3773. PubMed ID: 28241588
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Joint estimation of Stokes images and aberrations from phase-diverse polarimetric measurements.
    Valenzuela JR; Fessler JA; Paxman RG
    J Opt Soc Am A Opt Image Sci Vis; 2010 May; 27(5):1185-93. PubMed ID: 20448786
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Improved microgrid arrangement for integrated imaging polarimeters.
    LeMaster DA; Hirakawa K
    Opt Lett; 2014 Apr; 39(7):1811-4. PubMed ID: 24686611
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Precision of polarimetric orthogonal state contrast estimation in coherent images corrupted by speckle, Poisson, and additive noise.
    Dupont J; Boffety M; Goudail F
    J Opt Soc Am A Opt Image Sci Vis; 2018 Jun; 35(6):977-984. PubMed ID: 29877342
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Airlight-imposed errors for space-object polarimetric observations from the ground.
    Tyler DW; Demars C
    Appl Opt; 2018 Mar; 57(9):2235-2244. PubMed ID: 29604018
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Three-dimensional polarimetric integral imaging under low illumination conditions.
    Shen X; Carnicer A; Javidi B
    Opt Lett; 2019 Jul; 44(13):3230-3233. PubMed ID: 31259928
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Achromatization of waveplate for broadband polarimetric system.
    Mu T; Zhang C; Li Q; Liang R
    Opt Lett; 2015 Jun; 40(11):2485-8. PubMed ID: 26030538
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Handy method to calibrate division-of-amplitude polarimeters for the first three Stokes parameters.
    Morel O; Seulin R; Fofi D
    Opt Express; 2016 Jun; 24(12):13634-46. PubMed ID: 27410379
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Estimation of order parameter of a liquid crystal variable retarder using Haller's approximation.
    Tiwary AR; Raja Bayanna A; Mathew SK
    Appl Opt; 2017 May; 56(14):4180-4184. PubMed ID: 29047551
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.