These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
175 related articles for article (PubMed ID: 32635434)
21. Comparison of optical techniques and MeV SIMS in determining deposition order between optically distinguishable and indistinguishable inks from different writing tools. Barac M; Filko A; Siketić Z; Brajković M; Ledić A; Radović IB Forensic Sci Int; 2022 Feb; 331():111136. PubMed ID: 34920331 [TBL] [Abstract][Full Text] [Related]
22. Application of micro-attenuated total reflectance Fourier transform infrared spectroscopy to ink examination in signatures written with ballpoint pen on questioned documents. Nam YS; Park JS; Lee Y; Lee KB J Forensic Sci; 2014 May; 59(3):800-5. PubMed ID: 24661236 [TBL] [Abstract][Full Text] [Related]
23. Evaluating the potential of near infrared hyperspectral imaging associated with multivariate data analysis for examining crossing ink lines. Rodrigues E Brito L; Braz A; Saldanha Honorato R; Pimentel MF; Pasquini C Forensic Sci Int; 2019 May; 298():169-176. PubMed ID: 30909104 [TBL] [Abstract][Full Text] [Related]
24. Principal component analysis for the forensic discrimination of black inkjet inks based on the Vis-NIR fibre optics reflection spectra. Gál L; Oravec M; Gemeiner P; Čeppan M Forensic Sci Int; 2015 Dec; 257():285-292. PubMed ID: 26448533 [TBL] [Abstract][Full Text] [Related]
25. Determining line-crossing sequences between laser printing and black ink using digital microscopy: The influence of writing tool and toner. Meneghetti M; Mancini L; Caligiore G; Zampa F Forensic Sci Int; 2024 Jul; 360():112051. PubMed ID: 38749099 [TBL] [Abstract][Full Text] [Related]
26. TOF-SIMS Analysis of Red Color Inks of Writing and Printing Tools on Questioned Documents. Lee J; Nam YS; Min J; Lee KB; Lee Y J Forensic Sci; 2016 May; 61(3):815-22. PubMed ID: 27122425 [TBL] [Abstract][Full Text] [Related]
27. Application of micro-attenuated total reflectance FTIR spectroscopy in the forensic study of questioned documents involving red seal inks. Dirwono W; Park JS; Agustin-Camacho MR; Kim J; Park HM; Lee Y; Lee KB Forensic Sci Int; 2010 Jun; 199(1-3):6-8. PubMed ID: 20413232 [TBL] [Abstract][Full Text] [Related]
28. Study of ink aging: Targeting triethylene glycol in carbon-based black gel ink strokes on paper. Ni Y; He N; Lü Y; Zou N; Song H; Li H; Zhao P Forensic Sci Int; 2020 Jun; 311():110296. PubMed ID: 32344206 [TBL] [Abstract][Full Text] [Related]
29. Raman spectroscopy and laser desorption mass spectrometry for minimal destructive forensic analysis of black and color inkjet printed documents. Heudt L; Debois D; Zimmerman TA; Köhler L; Bano F; Partouche F; Duwez AS; Gilbert B; De Pauw E Forensic Sci Int; 2012 Jun; 219(1-3):64-75. PubMed ID: 22225847 [TBL] [Abstract][Full Text] [Related]
30. Discrimination of Pakistani Fountain Pen Inks by Gas Chromatography-Mass Spectrometry (GC-MS). Sharif M; Jalees MI; Ali Shah Tirmazi SA; Athar MM; Durrani AI; Batool M Int J Anal Chem; 2022; 2022():7186625. PubMed ID: 35401754 [TBL] [Abstract][Full Text] [Related]
31. Use of Raman spectroscopy and chemometrics to distinguish blue ballpoint pen inks. de Souza Lins Borba F; Honorato RS; de Juan A Forensic Sci Int; 2015 Apr; 249():73-82. PubMed ID: 25679985 [TBL] [Abstract][Full Text] [Related]
32. Ballpoint pen inks: characterization by positive and negative ion-electrospray ionization mass spectrometry for the forensic examination of writing inks. Ng LK; Lafontaine P; Brazeau L J Forensic Sci; 2002 Nov; 47(6):1238-47. PubMed ID: 12455644 [TBL] [Abstract][Full Text] [Related]
33. Challenges Determining the Correct Deposition Order of Different Intersecting Black Inks by Time-of-Flight Secondary Ion Mass Spectrometry. Goacher RE; DiFonzo LG; Lesko KC Anal Chem; 2017 Jan; 89(1):759-766. PubMed ID: 27936596 [TBL] [Abstract][Full Text] [Related]
34. Identification of colorants in pigmented pen inks by laser desorption mass spectrometry. Papson K; Stachura S; Boralsky L; Allison J J Forensic Sci; 2008 Jan; 53(1):100-6. PubMed ID: 18279246 [TBL] [Abstract][Full Text] [Related]
35. Preliminary Study on Determining the Sequence of Intersecting Lines by Fluorescence Technique. Li B; Ouyang GL; Zhao PN J Forensic Sci; 2018 Mar; 63(2):577-582. PubMed ID: 28585688 [TBL] [Abstract][Full Text] [Related]
36. Determination of the Chronological Order of a Laser Printing and Gel Pen Writing Without any Crossing Strokes. Gupta V; Saini K J Forensic Sci; 2020 Jul; 65(4):1337-1341. PubMed ID: 32069371 [TBL] [Abstract][Full Text] [Related]
37. Detection and identification of dyes in blue writing inks by LC-DAD-orbitrap MS. Sun Q; Luo Y; Yang X; Xiang P; Shen M Forensic Sci Int; 2016 Apr; 261():71-81. PubMed ID: 26894843 [TBL] [Abstract][Full Text] [Related]
38. [Determination of writing age of blue ballpoint pen inks by high performance liquid chromatography]. Shi XF; Li XQ; Xu YJ; Wang JH; Wang YJ Guang Pu Xue Yu Guang Pu Fen Xi; 2006 Sep; 26(9):1765-8. PubMed ID: 17112066 [TBL] [Abstract][Full Text] [Related]
39. Quantitative evaluation of europium in blue ballpoint pen inks/offset printing inks tagged with europium thenoyltrifluoroacetonate by spectrofluorometry and ICP-AES. Maind SD; Chattopadhyay N; Gandhi Ch; Kumar SC; Sudersanan M Sci Justice; 2008 Jun; 48(2):61-6. PubMed ID: 18700497 [TBL] [Abstract][Full Text] [Related]
40. Using Raman spectroscopy to solve crime: inks, questioned documents and fraud. Claybourn M; Ansell M Sci Justice; 2000; 40(4):261-71. PubMed ID: 11094823 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]