These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

250 related articles for article (PubMed ID: 32635526)

  • 1. IR-UWB Pulse Generation Using FPGA Scheme for through Obstacle Human Detection.
    Tantiparimongkol L; Phasukkit P
    Sensors (Basel); 2020 Jul; 20(13):. PubMed ID: 32635526
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An Overview of Signal Processing Techniques for Remote Health Monitoring Using Impulse Radio UWB Transceiver.
    Khan F; Ghaffar A; Khan N; Cho SH
    Sensors (Basel); 2020 Apr; 20(9):. PubMed ID: 32349382
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Preclinical Evaluation of a Noncontact Simultaneous Monitoring Method for Respiration and Carotid Pulsation Using Impulse-Radio Ultra-Wideband Radar.
    Park JY; Lee Y; Choi YW; Heo R; Park HK; Cho SH; Cho SH; Lim YH
    Sci Rep; 2019 Aug; 9(1):11892. PubMed ID: 31417149
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The Overview of Human Localization and Vital Sign Signal Measurement Using Handheld IR-UWB Through-Wall Radar.
    Yang D; Zhu Z; Zhang J; Liang B
    Sensors (Basel); 2021 Jan; 21(2):. PubMed ID: 33430061
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Experimental Comparison of IR-UWB Radar and FMCW Radar for Vital Signs.
    Wang D; Yoo S; Cho SH
    Sensors (Basel); 2020 Nov; 20(22):. PubMed ID: 33238557
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A UWB Radar Signal Processing Platform for Real-Time Human Respiratory Feature Extraction Based on Four-Segment Linear Waveform Model.
    Hsieh CH; Chiu YF; Shen YH; Chu TS; Huang YH
    IEEE Trans Biomed Circuits Syst; 2016 Feb; 10(1):219-30. PubMed ID: 25667357
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Respiration Based Non-Invasive Approach for Emotion Recognition Using Impulse Radio Ultra Wide Band Radar and Machine Learning.
    Siddiqui HUR; Shahzad HF; Saleem AA; Khan Khakwani AB; Rustam F; Lee E; Ashraf I; Dudley S
    Sensors (Basel); 2021 Dec; 21(24):. PubMed ID: 34960430
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A Novel Method for Breath Detection via Stepped-Frequency Continuous Wave Ultra-Wideband (SFCW UWB) Radars Based on Operational Bandwidth Segmentation.
    Lv H; Jiao T; Zhang Y; Liang F; Qi F; Wang J
    Sensors (Basel); 2018 Nov; 18(11):. PubMed ID: 30423841
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Short-Range Vital Signs Sensing Based on EEMD and CWT Using IR-UWB Radar.
    Hu X; Jin T
    Sensors (Basel); 2016 Nov; 16(12):. PubMed ID: 27916877
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Performance evaluation on FPGA-implemented UWB-IR receiver for in-body to out-of-body communication systems.
    Shimizu Y; Anzai D; Jianqing Wang
    Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():6981-4. PubMed ID: 25571602
    [TBL] [Abstract][Full Text] [Related]  

  • 11. 1-Tx/5-Rx Through-Wall UWB Switched-Antenna-Array Radar for Detecting Stationary Humans.
    Rittiplang A; Phasukkit P
    Sensors (Basel); 2020 Nov; 20(23):. PubMed ID: 33260403
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A Detailed Algorithm for Vital Sign Monitoring of a Stationary/Non-Stationary Human through IR-UWB Radar.
    Khan F; Cho SH
    Sensors (Basel); 2017 Feb; 17(2):. PubMed ID: 28165416
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Contactless Simultaneous Breathing and Heart Rate Detections in Physical Activity Using IR-UWB Radars.
    Zhang X; Yang X; Ding Y; Wang Y; Zhou J; Zhang L
    Sensors (Basel); 2021 Aug; 21(16):. PubMed ID: 34450945
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accurate Heart Rate and Respiration Rate Detection Based on a Higher-Order Harmonics Peak Selection Method Using Radar Non-Contact Sensors.
    Xu H; Ebrahim MP; Hasan K; Heydari F; Howley P; Yuce MR
    Sensors (Basel); 2021 Dec; 22(1):. PubMed ID: 35009628
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A novel through-wall respiration detection algorithm using UWB radar.
    Li X; Qiao D; Li Y; Dai H
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():1013-6. PubMed ID: 24109862
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A Non-Contact Detection Method for Multi-Person Vital Signs Based on IR-UWB Radar.
    Dang X; Zhang J; Hao Z
    Sensors (Basel); 2022 Aug; 22(16):. PubMed ID: 36015877
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Non-contact detection of myocardium's mechanical activity by ultrawideband RF-radar and interpretation applying electrocardiography.
    Thiel F; Kreiseler D; Seifert F
    Rev Sci Instrum; 2009 Nov; 80(11):114302. PubMed ID: 19947742
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Body Orientation and Vital Sign Measurement With IR-UWB Radar Network.
    Yang X; Yu Y; Qian H; Zhang X; Zhang L
    Annu Int Conf IEEE Eng Med Biol Soc; 2020 Jul; 2020():485-488. PubMed ID: 33018033
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Detection of motion and posture change using an IR-UWB radar.
    Van Nguyen ; Javaid AQ; Weitnauer MA
    Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():3650-3653. PubMed ID: 28269085
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A Novel Non-contact Heart Rate Monitor Using Impulse-Radio Ultra-Wideband (IR-UWB) Radar Technology.
    Lee Y; Park JY; Choi YW; Park HK; Cho SH; Cho SH; Lim YH
    Sci Rep; 2018 Aug; 8(1):13053. PubMed ID: 30158545
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.