These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 32635992)

  • 1. Study on the bending behavior of biodegradable metal cerebral vascular stents using finite element analysis.
    Shi W; Li H; Zhu T; Jin Y; Wang H; Yang J; Zhao D
    J Biomech; 2020 Jul; 108():109856. PubMed ID: 32635992
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Bending behaviors of fully covered biodegradable polydioxanone biliary stent for human body by finite element method.
    Liu Y; Zhu G; Yang H; Wang C; Zhang P; Han G
    J Mech Behav Biomed Mater; 2018 Jan; 77():157-163. PubMed ID: 28917130
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of stent structure on stent flexibility measurements.
    Mori K; Saito T
    Ann Biomed Eng; 2005 Jun; 33(6):733-42. PubMed ID: 16078613
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Repeated unit cell (RUC) approach for pure bending analysis of coronary stents.
    Ju F; Xia Z; Zhou C
    Comput Methods Biomech Biomed Engin; 2008 Aug; 11(4):419-31. PubMed ID: 18568836
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Computational Bench Testing to Evaluate the Short-Term Mechanical Performance of a Polymeric Stent.
    Bobel AC; Petisco S; Sarasua JR; Wang W; McHugh PE
    Cardiovasc Eng Technol; 2015 Dec; 6(4):519-32. PubMed ID: 26577483
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Design method of self-expanding stents suitable for the patient's condition.
    Yoshino D; Inoue K
    Proc Inst Mech Eng H; 2010; 224(9):1019-38. PubMed ID: 21053768
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Numerical investigations of the mechanical properties of braided vascular stents.
    Fu W; Xia Q; Yan R; Qiao A
    Biomed Mater Eng; 2018; 29(1):81-94. PubMed ID: 29254075
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Mechanical design of an intracranial stent for treating cerebral aneurysms.
    Shobayashi Y; Tanoue T; Tateshima S; Tanishita K
    Med Eng Phys; 2010 Nov; 32(9):1015-24. PubMed ID: 20675176
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A biodegradable magnesium alloy vascular stent structure: Design, optimisation and evaluation.
    Li Y; Wang Y; Shen Z; Miao F; Wang J; Sun Y; Zhu S; Zheng Y; Guan S
    Acta Biomater; 2022 Apr; 142():402-412. PubMed ID: 35085798
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Design optimization of stent and its dilatation balloon using kriging surrogate model.
    Li H; Liu T; Wang M; Zhao D; Qiao A; Wang X; Gu J; Li Z; Zhu B
    Biomed Eng Online; 2017 Jan; 16(1):13. PubMed ID: 28086895
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Structure design and mechanical performance analysis of three kinds of bioresorbable poly-lactic acid (PLA) stents.
    Wang Y; Wu H; Fan S; Wu J; Yang S
    Comput Methods Biomech Biomed Engin; 2023 Jan; 26(1):25-37. PubMed ID: 35341394
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Computational and experimental investigation into mechanical performances of Poly-L-Lactide Acid (PLLA) coronary stents.
    Wang Q; Fang G; Zhao Y; Wang G; Cai T
    J Mech Behav Biomed Mater; 2017 Jan; 65():415-427. PubMed ID: 27643678
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Numerical simulation on the effects of drug-eluting stents with different bending angles on hemodynamics and drug distribution.
    Chen Y; Xiong Y; Jiang W; Wong MS; Yan F; Wang Q; Fan Y
    Med Biol Eng Comput; 2016 Dec; 54(12):1859-1870. PubMed ID: 27048391
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Mechanical behavior of coronary stents investigated through the finite element method.
    Migliavacca F; Petrini L; Colombo M; Auricchio F; Pietrabissa R
    J Biomech; 2002 Jun; 35(6):803-11. PubMed ID: 12021000
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Finite element analyses for improved design of peripheral stents.
    Lim YH; Jeong HY
    Comput Methods Biomech Biomed Engin; 2017 May; 20(6):653-662. PubMed ID: 28349767
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Finite element analysis of braided dense-mesh stents for carotid artery stenosis.
    Zhao Y; Cui H
    Comput Methods Biomech Biomed Engin; 2024 Apr; 27(5):609-619. PubMed ID: 37018022
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Finite element analysis and stent design: Reduction of dogboning.
    De Beule M; Van Impe R; Verhegghe B; Segers P; Verdonck P
    Technol Health Care; 2006; 14(4-5):233-41. PubMed ID: 17065746
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Finite element analysis of the expansion behavior of coronary stents].
    Wang W; Yang D; Qi M
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2006 Dec; 23(6):1258-62, 1266. PubMed ID: 17228721
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Future Balloon-Expandable Stents: High or Low-Strength Materials?
    Khalilimeybodi A; Alishzadeh Khoei A; Sharif-Kashani B
    Cardiovasc Eng Technol; 2020 Apr; 11(2):188-204. PubMed ID: 31836964
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Comparative study on the mechanical properties of lower limb arterial stents under various deformation modes].
    Wang T; Feng H; Wang K
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2021 Apr; 38(2):303-309. PubMed ID: 33913290
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.