163 related articles for article (PubMed ID: 3264020)
1. Assessment and comparison of three scatter correction techniques in single photon emission computed tomography.
Gilardi MC; Bettinardi V; Todd-Pokropek A; Milanesi L; Fazio F
J Nucl Med; 1988 Dec; 29(12):1971-9. PubMed ID: 3264020
[TBL] [Abstract][Full Text] [Related]
2. Inverse Monte Carlo as a unified reconstruction algorithm for ECT.
Floyd CE; Jaszczak RJ; Greer KL; Coleman RE
J Nucl Med; 1986 Oct; 27(10):1577-85. PubMed ID: 3489822
[TBL] [Abstract][Full Text] [Related]
3. Attenuation and scatter correction in SPECT for sources in a nonhomogeneous object: a monte Carlo study.
Ljungberg M; Strand SE
J Nucl Med; 1991 Jun; 32(6):1278-84. PubMed ID: 2045947
[TBL] [Abstract][Full Text] [Related]
4. Generalized scatter correction method in SPECT using point scatter distribution functions.
Msaki P; Axelsson B; Dahl CM; Larsson SA
J Nucl Med; 1987 Dec; 28(12):1861-9. PubMed ID: 3500288
[TBL] [Abstract][Full Text] [Related]
5. Comparative assessment of nine scatter correction methods based on spectral analysis using Monte Carlo simulations.
Buvat I; Rodriguez-Villafuerte M; Todd-Pokropek A; Benali H; Di Paola R
J Nucl Med; 1995 Aug; 36(8):1476-88. PubMed ID: 7629598
[TBL] [Abstract][Full Text] [Related]
6. Scatter and attenuation correction in SPECT using density maps and Monte Carlo simulated scatter functions.
Ljungberg M; Strand SE
J Nucl Med; 1990 Sep; 31(9):1560-7. PubMed ID: 2395025
[TBL] [Abstract][Full Text] [Related]
7. Deconvolution of Compton scatter in SPECT.
Floyd CE; Jaszczak RJ; Greer KL; Coleman RE
J Nucl Med; 1985 Apr; 26(4):403-8. PubMed ID: 3872353
[TBL] [Abstract][Full Text] [Related]
8. Treatment of Compton scattering in maximum-likelihood, expectation-maximization reconstructions of SPECT images.
Bowsher JE; Floyd CE
J Nucl Med; 1991 Jun; 32(6):1285-91. PubMed ID: 2045948
[TBL] [Abstract][Full Text] [Related]
9. [Evaluation of a scatter correction technique for single photon transmission measurements in PET by means of Monte Carlo simulations].
Wegmann K; Brix G
Nuklearmedizin; 2000; 39(3):67-71. PubMed ID: 10834193
[TBL] [Abstract][Full Text] [Related]
10. Photon energy recovery: a method to improve the effective energy resolution of gamma cameras.
Hannequin PP; Mas JF
J Nucl Med; 1998 Mar; 39(3):555-62. PubMed ID: 9529311
[TBL] [Abstract][Full Text] [Related]
11. Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation.
Beekman FJ; de Jong HW; van Geloven S
IEEE Trans Med Imaging; 2002 Aug; 21(8):867-77. PubMed ID: 12472260
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of reconstruction techniques in regional cerebral blood flow SPECT using trade-off plots: a Monte Carlo study.
Olsson A; Arlig A; Carlsson GA; Gustafsson A
Nucl Med Commun; 2007 Sep; 28(9):719-25. PubMed ID: 17667751
[TBL] [Abstract][Full Text] [Related]
13. Nonisotropic attenuation in SPECT: phantom tests of quantitative effects and compensation techniques.
Manglos SH; Jaszczak RJ; Floyd CE; Hahn LJ; Greer KL; Coleman RE
J Nucl Med; 1987 Oct; 28(10):1584-91. PubMed ID: 3498805
[TBL] [Abstract][Full Text] [Related]
14. Hybrid scatter correction applied to quantitative holmium-166 SPECT.
de Wit TC; Xiao J; Nijsen JF; van het Schip FD; Staelens SG; van Rijk PP; Beekman FJ
Phys Med Biol; 2006 Oct; 51(19):4773-87. PubMed ID: 16985270
[TBL] [Abstract][Full Text] [Related]
15. SPECT Compton-scattering correction by analysis of energy spectra.
Koral KF; Wang XQ; Rogers WL; Clinthorne NH; Wang XH
J Nucl Med; 1988 Feb; 29(2):195-202. PubMed ID: 3258023
[TBL] [Abstract][Full Text] [Related]
16. Monte Carlo-based analysis of PET scatter components.
Adam LE; Bellemann ME; Brix G; Lorenz WJ
J Nucl Med; 1996 Dec; 37(12):2024-9. PubMed ID: 8970528
[TBL] [Abstract][Full Text] [Related]
17. Energy dependence of nonstationary scatter subtraction--restoration in high resolution PET.
Bentourkia M; Lecomte R
IEEE Trans Med Imaging; 1999 Jan; 18(1):66-73. PubMed ID: 10193698
[TBL] [Abstract][Full Text] [Related]
18. Comparison of three boundary detection methods for SPECT using Compton scattered photons.
Macey DJ; DeNardo GL; DeNardo SJ
J Nucl Med; 1988 Feb; 29(2):203-7. PubMed ID: 3258024
[TBL] [Abstract][Full Text] [Related]
19. Assessment of scatter components in high-resolution PET: correction by nonstationary convolution subtraction.
Bentourkia M; Msaki P; Cadorette J; Lecomte R
J Nucl Med; 1995 Jan; 36(1):121-30. PubMed ID: 7799064
[TBL] [Abstract][Full Text] [Related]
20. Nonstationary scatter subtraction-restoration in high-resolution PET.
Bentourkia M; Msaki P; Cadorette J; Lecomte R
J Nucl Med; 1996 Dec; 37(12):2040-6. PubMed ID: 8970531
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]