BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 3264020)

  • 1. Assessment and comparison of three scatter correction techniques in single photon emission computed tomography.
    Gilardi MC; Bettinardi V; Todd-Pokropek A; Milanesi L; Fazio F
    J Nucl Med; 1988 Dec; 29(12):1971-9. PubMed ID: 3264020
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Inverse Monte Carlo as a unified reconstruction algorithm for ECT.
    Floyd CE; Jaszczak RJ; Greer KL; Coleman RE
    J Nucl Med; 1986 Oct; 27(10):1577-85. PubMed ID: 3489822
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Attenuation and scatter correction in SPECT for sources in a nonhomogeneous object: a monte Carlo study.
    Ljungberg M; Strand SE
    J Nucl Med; 1991 Jun; 32(6):1278-84. PubMed ID: 2045947
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Generalized scatter correction method in SPECT using point scatter distribution functions.
    Msaki P; Axelsson B; Dahl CM; Larsson SA
    J Nucl Med; 1987 Dec; 28(12):1861-9. PubMed ID: 3500288
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparative assessment of nine scatter correction methods based on spectral analysis using Monte Carlo simulations.
    Buvat I; Rodriguez-Villafuerte M; Todd-Pokropek A; Benali H; Di Paola R
    J Nucl Med; 1995 Aug; 36(8):1476-88. PubMed ID: 7629598
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Scatter and attenuation correction in SPECT using density maps and Monte Carlo simulated scatter functions.
    Ljungberg M; Strand SE
    J Nucl Med; 1990 Sep; 31(9):1560-7. PubMed ID: 2395025
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Deconvolution of Compton scatter in SPECT.
    Floyd CE; Jaszczak RJ; Greer KL; Coleman RE
    J Nucl Med; 1985 Apr; 26(4):403-8. PubMed ID: 3872353
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Treatment of Compton scattering in maximum-likelihood, expectation-maximization reconstructions of SPECT images.
    Bowsher JE; Floyd CE
    J Nucl Med; 1991 Jun; 32(6):1285-91. PubMed ID: 2045948
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Evaluation of a scatter correction technique for single photon transmission measurements in PET by means of Monte Carlo simulations].
    Wegmann K; Brix G
    Nuklearmedizin; 2000; 39(3):67-71. PubMed ID: 10834193
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Photon energy recovery: a method to improve the effective energy resolution of gamma cameras.
    Hannequin PP; Mas JF
    J Nucl Med; 1998 Mar; 39(3):555-62. PubMed ID: 9529311
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensation.
    Beekman FJ; de Jong HW; van Geloven S
    IEEE Trans Med Imaging; 2002 Aug; 21(8):867-77. PubMed ID: 12472260
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of reconstruction techniques in regional cerebral blood flow SPECT using trade-off plots: a Monte Carlo study.
    Olsson A; Arlig A; Carlsson GA; Gustafsson A
    Nucl Med Commun; 2007 Sep; 28(9):719-25. PubMed ID: 17667751
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Nonisotropic attenuation in SPECT: phantom tests of quantitative effects and compensation techniques.
    Manglos SH; Jaszczak RJ; Floyd CE; Hahn LJ; Greer KL; Coleman RE
    J Nucl Med; 1987 Oct; 28(10):1584-91. PubMed ID: 3498805
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Hybrid scatter correction applied to quantitative holmium-166 SPECT.
    de Wit TC; Xiao J; Nijsen JF; van het Schip FD; Staelens SG; van Rijk PP; Beekman FJ
    Phys Med Biol; 2006 Oct; 51(19):4773-87. PubMed ID: 16985270
    [TBL] [Abstract][Full Text] [Related]  

  • 15. SPECT Compton-scattering correction by analysis of energy spectra.
    Koral KF; Wang XQ; Rogers WL; Clinthorne NH; Wang XH
    J Nucl Med; 1988 Feb; 29(2):195-202. PubMed ID: 3258023
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Monte Carlo-based analysis of PET scatter components.
    Adam LE; Bellemann ME; Brix G; Lorenz WJ
    J Nucl Med; 1996 Dec; 37(12):2024-9. PubMed ID: 8970528
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Energy dependence of nonstationary scatter subtraction--restoration in high resolution PET.
    Bentourkia M; Lecomte R
    IEEE Trans Med Imaging; 1999 Jan; 18(1):66-73. PubMed ID: 10193698
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of three boundary detection methods for SPECT using Compton scattered photons.
    Macey DJ; DeNardo GL; DeNardo SJ
    J Nucl Med; 1988 Feb; 29(2):203-7. PubMed ID: 3258024
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Assessment of scatter components in high-resolution PET: correction by nonstationary convolution subtraction.
    Bentourkia M; Msaki P; Cadorette J; Lecomte R
    J Nucl Med; 1995 Jan; 36(1):121-30. PubMed ID: 7799064
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Nonstationary scatter subtraction-restoration in high-resolution PET.
    Bentourkia M; Msaki P; Cadorette J; Lecomte R
    J Nucl Med; 1996 Dec; 37(12):2040-6. PubMed ID: 8970531
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.