BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

414 related articles for article (PubMed ID: 32646304)

  • 1. Balloon Versus Self-Expandable Valve for the Treatment of Bicuspid Aortic Valve Stenosis: Insights From the BEAT International Collaborative Registrys.
    Mangieri A; Tchetchè D; Kim WK; Pagnesi M; Sinning JM; Landes U; Kornowski R; De Backer O; Nickenig G; Ielasi A; De Biase C; Søndergaard L; De Marco F; Montorfano M; Chiarito M; Regazzoli D; Stefanini G; Presbitero P; Toggweiler S; Tamburino C; Immè S; Tarantini G; Sievert H; Schäfer U; Kempfert J; Wöehrle J; Gallo F; Laricchia A; Latib A; Giannini F; Colombo A
    Circ Cardiovasc Interv; 2020 Jul; 13(7):e008714. PubMed ID: 32646304
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Three-year clinical outcomes after transcatheter aortic valve implantation in patients with bicuspid aortic disease: Comparison between self-expanding and balloon-expandable valves.
    Boiago M; Bellamoli M; De Biase C; Beneduce A; Alonso LG; Laforgia P; Feliachi S; Oliva OA; Dumonteil N; Tchétché D
    Catheter Cardiovasc Interv; 2024 May; 103(6):1004-1014. PubMed ID: 38577939
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bioprosthetic Valve Performance After Transcatheter Aortic Valve Replacement With Self-Expanding Versus Balloon-Expandable Valves in Large Versus Small Aortic Valve Annuli: Insights From the CHOICE Trial and the CHOICE-Extend Registry.
    Abdelghani M; Mankerious N; Allali A; Landt M; Kaur J; Sulimov DS; Merten C; Sachse S; Mehilli J; Neumann FJ; Frerker C; Kurz T; El-Mawardy M; Richardt G; Abdel-Wahab M
    JACC Cardiovasc Interv; 2018 Dec; 11(24):2507-2518. PubMed ID: 30503595
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Transcatheter Self-Expandable Valve Implantation for Aortic Stenosis in Small Aortic Annuli: The TAVI-SMALL Registry.
    Regazzoli D; Chiarito M; Cannata F; Pagnesi M; Miura M; Ziviello F; Picci A; Reifart J; De Marco F; Bedogni F; Adamo M; Curello S; Teles R; Taramasso M; Barbanti M; Tamburino C; Stefanini GG; Mangieri A; Giannini F; Pagnotta PA; Maisano F; Kim WK; Van Mieghem NM; Colombo A; Reimers B; Latib A;
    JACC Cardiovasc Interv; 2020 Jan; 13(2):196-206. PubMed ID: 31883714
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Third-Generation Balloon and Self-Expandable Valves for Aortic Stenosis in Large and Extra-Large Aortic Annuli From the TAVR-LARGE Registry.
    Armijo G; Tang GHL; Kooistra N; Ferreira-Neto AN; Toggweiler S; Amat-Santos IJ; Keller LS; Urena M; Ahmad H; Tafur Soto J; Muñoz-Garcia E; Regueiro A; Leenders GE; Tirado-Conte G; Sengupta A; McInerney A; Couture T; Cuevas Herreros O; Rodriguez-Gabella T; Kini A; Ahmed M; Zaid S; Gonzalo N; Nuñez-Gil IJ; Muñoz-Garcia AJ; Jimenez-Quevedo P; Fernández-Ortiz A; Himbert D; Nietlispach F; Stella P; Dangas GD; Escaned J; Macaya C; Rodés-Cabau J; Nombela-Franco L
    Circ Cardiovasc Interv; 2020 Aug; 13(8):e009047. PubMed ID: 32757657
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Transcatheter Aortic Valve Replacement in Bicuspid Versus Tricuspid Aortic Valves From the STS/ACC TVT Registry.
    Forrest JK; Kaple RK; Ramlawi B; Gleason TG; Meduri CU; Yakubov SJ; Jilaihawi H; Liu F; Reardon MJ
    JACC Cardiovasc Interv; 2020 Aug; 13(15):1749-1759. PubMed ID: 32473890
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Transcatheter Aortic Valve Replacement With Next-Generation Self-Expanding Devices: A Multicenter, Retrospective, Propensity-Matched Comparison of Evolut PRO Versus Acurate neo Transcatheter Heart Valves.
    Pagnesi M; Kim WK; Conradi L; Barbanti M; Stefanini GG; Zeus T; Pilgrim T; Schofer J; Zweiker D; Testa L; Taramasso M; Hildick-Smith D; Abizaid A; Wolf A; Van Mieghem NM; Sedaghat A; Wöhrle J; Khogali S; Van der Heyden JAS; Webb JG; Estévez-Loureiro R; Mylotte D; MacCarthy P; Brugaletta S; Hamm CW; Bhadra OD; Schäfer U; Costa G; Tamburino C; Cannata F; Reimers B; Veulemans V; Asami M; Windecker S; Eitan A; Schmidt A; Bianchi G; Bedogni F; Saccocci M; Maisano F; Alsanjari O; Siqueira D; Jensen CJ; Naber CK; Ziviello F; Sinning JM; Seeger J; Rottbauer W; Brouwer J; Alenezi A; Wood DA; Tzalamouras V; Regueiro A; Colombo A; Latib A
    JACC Cardiovasc Interv; 2019 Mar; 12(5):433-443. PubMed ID: 30846081
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Outcomes of three different new generation transcatheter aortic valve prostheses.
    Costa G; Buccheri S; Barbanti M; Picci A; Todaro D; Di Simone E; La Spina K; D'Arrigo P; Criscione E; Nastasi M; Sgroi C; Tamburino C
    Catheter Cardiovasc Interv; 2020 Feb; 95(3):398-407. PubMed ID: 31609073
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Three Generations of Self-Expanding Transcatheter Aortic Valves: A Report From the STS/ACC TVT Registry.
    Forrest JK; Kaple RK; Tang GHL; Yakubov SJ; Nazif TM; Williams MR; Zhang A; Popma JJ; Reardon MJ
    JACC Cardiovasc Interv; 2020 Jan; 13(2):170-179. PubMed ID: 31973793
    [TBL] [Abstract][Full Text] [Related]  

  • 10. 5-Year Outcomes After TAVR With Balloon-Expandable Versus Self-Expanding Valves: Results From the CHOICE Randomized Clinical Trial.
    Abdel-Wahab M; Landt M; Neumann FJ; Massberg S; Frerker C; Kurz T; Kaur J; Toelg R; Sachse S; Jochheim D; Schäfer U; El-Mawardy M; Robinson DR; Richardt G;
    JACC Cardiovasc Interv; 2020 May; 13(9):1071-1082. PubMed ID: 32305398
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Transfemoral aortic valve implantation with new-generation devices: the repositionable Lotus vs. the balloon-expandable Edwards Sapien 3 valve.
    Nai Fovino L; Badawy MRA; Fraccaro C; D'Onofrio A; Purita PAM; Frigo AC; Tellaroli P; Mauro A; Tusa M; Napodano M; Gerosa G; Iliceto S; Bedogni F; AbdelRheim AER; Tarantini G
    J Cardiovasc Med (Hagerstown); 2018 Nov; 19(11):655-663. PubMed ID: 30299408
    [TBL] [Abstract][Full Text] [Related]  

  • 12. ACURATE neo2 Versus SAPIEN 3 Ultra Transcatheter Heart Valve in Severe Aortic Valve Calcification: A Propensity-Matched Analysis.
    Eckel C; Kim WK; Sötemann D; Grothusen C; Tiyerili V; Dohmen G; Renker M; Charitos EI; Hamm CW; Choi YH; Elsässer A; Möllmann H; Blumenstein J
    Circ Cardiovasc Interv; 2024 May; 17(5):e013608. PubMed ID: 38529637
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Clinical Outcomes of the Self-Expandable Evolut R Valve Versus the Balloon-Expandable SAPIEN 3 Valve in Transcatheter Aortic Valve Implantation: A Meta-Analysis and Systematic Review.
    Al-Abcha A; Saleh Y; Charles L; Prasad R; Baloch ZQ; Hasan MA; Abela GS
    Cardiovasc Revasc Med; 2021 Apr; 25():57-62. PubMed ID: 33160895
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Latest-iteration balloon- and self-expandable transcatheter valves for severe bicuspid aortic stenosis: the TRITON study.
    Amat-Santos IJ; García-Gómez M; de Marco F; Won-Keun K; Brito J; Halim J; Jose J; Sengotuvelu G; Seth A; Terkelsen C; Protasiewicz M; Bonilla N; García B; Sánchez-Luna JP; Blasco-Turrión S; González JC; González-Bartol E; Ijsselmuiden AJJ; Gómez-Salvador I; Carrasco Moraleja M; San Román A
    Rev Esp Cardiol (Engl Ed); 2023 Nov; 76(11):872-880. PubMed ID: 36898524
    [TBL] [Abstract][Full Text] [Related]  

  • 15. 1-Year Outcomes With the Evolut R Self-Expanding Transcatheter Aortic Valve: From the International FORWARD Study.
    Manoharan G; Van Mieghem NM; Windecker S; Bosmans J; Bleiziffer S; Modine T; Linke A; Scholtz W; Chevalier B; Gooley R; Zeng C; Oh JK; Grube E
    JACC Cardiovasc Interv; 2018 Nov; 11(22):2326-2334. PubMed ID: 30466832
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Mid-term outcome in patients with bicuspid aortic valve stenosis following transcatheter aortic valve replacement with a current generation device: A multicenter study.
    Attinger-Toller A; Bhindi R; Perlman GY; Murdoch D; Weir-McCall J; Blanke P; Barbanti M; Sathananthan J; Ruile P; Gandolfo C; Saia F; Nietlispach F; Wood D; Leipsic J; Webb JG
    Catheter Cardiovasc Interv; 2020 May; 95(6):1186-1192. PubMed ID: 31483555
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comprehensive Echocardiographic Assessment of Normal Transcatheter Valve Function.
    Hahn RT; Leipsic J; Douglas PS; Jaber WA; Weissman NJ; Pibarot P; Blanke P; Oh JK
    JACC Cardiovasc Imaging; 2019 Jan; 12(1):25-34. PubMed ID: 29909110
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Transcatheter Replacement of Failed Bioprosthetic Valves: Large Multicenter Assessment of the Effect of Implantation Depth on Hemodynamics After Aortic Valve-in-Valve.
    Simonato M; Webb J; Kornowski R; Vahanian A; Frerker C; Nissen H; Bleiziffer S; Duncan A; Rodés-Cabau J; Attizzani GF; Horlick E; Latib A; Bekeredjian R; Barbanti M; Lefevre T; Cerillo A; Hernández JM; Bruschi G; Spargias K; Iadanza A; Brecker S; Palma JH; Finkelstein A; Abdel-Wahab M; Lemos P; Petronio AS; Champagnac D; Sinning JM; Salizzoni S; Napodano M; Fiorina C; Marzocchi A; Leon M; Dvir D
    Circ Cardiovasc Interv; 2016 Jun; 9(6):. PubMed ID: 27301396
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Outcomes of transfemoral balloon expandable transcatheter aortic valve implantation: Comparison of two subsequent valve generations.
    Schymik G; Wendler O; Hengstenberg C; Ohlmann P; Gilard M; Digne F; Souteyrand G; Letocart V; van Belle E; Bramlage P; Tarantini G;
    Catheter Cardiovasc Interv; 2020 Oct; 96(4):930-939. PubMed ID: 31794159
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Performance of the Evolut-R 34 mm versus Sapien-3 29 mm in Transcatheter aortic valve replacement patients with larger annuli: Early outcome results of Evolut-R 34 mm as compared with Sapien-3 29 mm in patients with Annuli ≥26 mm.
    Eitan A; Witt J; Stripling J; Haselbach T; Rieß FC; Schofer J
    Catheter Cardiovasc Interv; 2018 Dec; 92(7):1374-1379. PubMed ID: 29521464
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 21.