BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

105 related articles for article (PubMed ID: 3264784)

  • 1. Conversion of logarithmic channel numbers into relative linear fluorescence intensity.
    Schmid I; Schmid P; Giorgi JV
    Cytometry; 1988 Nov; 9(6):533-8. PubMed ID: 3264784
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Determination of linear fluorescence intensities from flow cytometric data accumulated with logarithmic amplifiers.
    Muirhead KA; Schmitt TC; Muirhead AR
    Cytometry; 1983 Jan; 3(4):251-6. PubMed ID: 6822146
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A simple and rapid method for determining the linearity of a flow cytometer amplification system.
    Bagwell CB; Baker D; Whetstone S; Munson M; Hitchcox S; Ault KA; Lovett EJ
    Cytometry; 1989 Nov; 10(6):689-94. PubMed ID: 2582958
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Computing the central location of immunofluorescence distributions: logarithmic data transformations are not always appropriate.
    Coder DM; Redelman D; Vogt RF
    Cytometry; 1994 Jun; 18(2):75-8. PubMed ID: 7924701
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Calibration of flow cytometry detector systems.
    Durand RE
    Cytometry; 1981 Nov; 2(3):192-3. PubMed ID: 7297355
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Photomultiplier voltage setting: possible important source of variability in molecular equivalents of soluble fluorochrome (MESF) calculation?
    Rigolin GM; Lanza F; Castoldi G
    Cytometry; 1995 Aug; 20(4):362-8. PubMed ID: 7587725
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Toward quantitative fluorescence measurements with multicolor flow cytometry.
    Wang L; Gaigalas AK; Marti G; Abbasi F; Hoffman RA
    Cytometry A; 2008 Apr; 73(4):279-88. PubMed ID: 18163471
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Inter-laboratory relative fluorescence intensity measurements using FlowCal 575 calibration beads: a baseline study.
    Waxdal MJ; Monical MC; Palini AG
    Cytometry; 1998 Oct; 33(2):213-8. PubMed ID: 9773882
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Hyperlog-a flexible log-like transform for negative, zero, and positive valued data.
    Bagwell CB
    Cytometry A; 2005 Mar; 64(1):34-42. PubMed ID: 15700280
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A new "Logicle" display method avoids deceptive effects of logarithmic scaling for low signals and compensated data.
    Parks DR; Roederer M; Moore WA
    Cytometry A; 2006 Jun; 69(6):541-51. PubMed ID: 16604519
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The look-up table: a logarithmic converter for cell sorters.
    Koper GJ; Blanken R
    Cytometry; 1981 Nov; 2(3):194-7. PubMed ID: 7297356
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Fluorescence-intensity multiplexing: simultaneous seven-marker, two-color immunophenotyping using flow cytometry.
    Bradford JA; Buller G; Suter M; Ignatius M; Beechem JM
    Cytometry A; 2004 Oct; 61(2):142-52. PubMed ID: 15382027
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A method for calibration of flow cytometric wavelength shift fluorescence measurements.
    Kachel V; Kempski O; Peters J; Schödel F
    Cytometry; 1990; 11(8):913-5. PubMed ID: 2272252
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Monitoring CD4 in whole blood with an opto-fluidic detector based on spatially modulated fluorescence emission.
    Kiesel P; Beck M; Johnson N
    Cytometry A; 2011 Apr; 79(4):317-24. PubMed ID: 21432992
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Long wavelength fluorophores and cell-by-cell correction for autofluorescence significantly improves the accuracy of flow cytometric energy transfer measurements on a dual-laser benchtop flow cytometer.
    Sebestyén Z; Nagy P; Horváth G; Vámosi G; Debets R; Gratama JW; Alexander DR; Szöllosi J
    Cytometry; 2002 Jul; 48(3):124-35. PubMed ID: 12116358
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Phase-resolved fluorescence lifetime measurements for flow cytometry.
    Pinsky BG; Ladasky JJ; Lakowicz JR; Berndt K; Hoffman RA
    Cytometry; 1993; 14(2):123-35. PubMed ID: 8440147
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A combined HIV-1 protein bead array for serology assay and T-cell subset immunophenotyping with a hybrid flow cytometer: a step in the direction of a comprehensive multitasking instrument platform for infectious disease diagnosis and monitoring.
    Faucher S; Martel A; Sherring A; Bogdanovic D; Malloch L; Kim JE; Bergeron M; Sandstrom P; Mandy FF
    Cytometry B Clin Cytom; 2006 May; 70(3):179-88. PubMed ID: 16615079
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Optimal preparation of rhesus macaque blood for cytokine flow cytometric analysis.
    Nomura LE; deHaro ED; Martin LN; Maecker HT
    Cytometry A; 2003 May; 53(1):28-38. PubMed ID: 12701130
    [TBL] [Abstract][Full Text] [Related]  

  • 19. CD4+ T-lymphocyte enumeration with a flow-rate based method in three flow cytometers with different years in service.
    Pattanapanyasat K; Chimma P; Sratongno P; Lerdwana S
    Cytometry B Clin Cytom; 2008 Sep; 74(5):310-8. PubMed ID: 18481294
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Logarithmic amplifiers.
    Gandler W; Shapiro H
    Cytometry; 1990; 11(3):447-50. PubMed ID: 2340779
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.