These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 32649048)

  • 41. Value of corneal epithelial and Bowman's layer vertical thickness profiles generated by UHR-OCT for sub-clinical keratoconus diagnosis.
    Xu Z; Jiang J; Yang C; Huang S; Peng M; Li W; Cui L; Wang J; Lu F; Shen M
    Sci Rep; 2016 Aug; 6():31550. PubMed ID: 27511620
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Integration of Scheimpflug-Based Corneal Tomography and Biomechanical Assessments for Enhancing Ectasia Detection.
    Ambrósio R; Lopes BT; Faria-Correia F; Salomão MQ; Bühren J; Roberts CJ; Elsheikh A; Vinciguerra R; Vinciguerra P
    J Refract Surg; 2017 Jul; 33(7):434-443. PubMed ID: 28681902
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Distinguishing Keratoconic Eyes and Healthy Eyes Using Ultrahigh-Resolution Optical Coherence Tomography-Based Corneal Epithelium Thickness Mapping.
    Pircher N; Schwarzhans F; Holzer S; Lammer J; Schmidl D; Bata AM; Werkmeister RM; Seidel G; Garhöfer G; Gschließer A; Schmetterer L; Schmidinger G
    Am J Ophthalmol; 2018 May; 189():47-54. PubMed ID: 29458037
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Differentiating Keratoconus and Corneal Warpage by Analyzing Focal Change Patterns in Corneal Topography, Pachymetry, and Epithelial Thickness Maps.
    Tang M; Li Y; Chamberlain W; Louie DJ; Schallhorn JM; Huang D
    Invest Ophthalmol Vis Sci; 2016 Jul; 57(9):OCT544-9. PubMed ID: 27482824
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Long-term Chronological Changes in Very Asymmetric Keratoconus.
    Koh S; Inoue R; Maeda N; Kabata D; Shintani A; Jhanji V; Klyce SD; Maruyama K; Nishida K
    Cornea; 2019 May; 38(5):605-611. PubMed ID: 30702472
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Comprehensive evaluation of corneas from normal, forme fruste keratoconus and clinical keratoconus patients using morphological and biomechanical properties.
    Zhang H; Tian L; Guo L; Qin X; Zhang D; Li L; Jie Y; Zhang H
    Int Ophthalmol; 2021 Apr; 41(4):1247-1259. PubMed ID: 33389426
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Differential Molecular Expression of Extracellular Matrix and Inflammatory Genes at the Corneal Cone Apex Drives Focal Weakening in Keratoconus.
    Pahuja N; Kumar NR; Shroff R; Shetty R; Nuijts RM; Ghosh A; Sinha-Roy A; Chaurasia SS; Mohan RR; Ghosh A
    Invest Ophthalmol Vis Sci; 2016 Oct; 57(13):5372-5382. PubMed ID: 27732724
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Astigmatic Vector Analysis of Posterior Corneal Surface: A Comparison Among Healthy, Forme Fruste, and Overt Keratoconic Corneas.
    Freitas Gde O; Ambrósio R; Ramos I; Lopes B; Valbon Bde F; Botteon C; Alve MR
    Am J Ophthalmol; 2016 Jul; 167():65-71. PubMed ID: 27130370
    [TBL] [Abstract][Full Text] [Related]  

  • 49. [Characteristics of corneal topography in parents of keratoconus patients].
    Li J; Jing LL; Du XL
    Zhonghua Yan Ke Za Zhi; 2020 Jun; 56(6):456-464. PubMed ID: 32842328
    [No Abstract]   [Full Text] [Related]  

  • 50. Subclinical keratoconus detection by pattern analysis of corneal and epithelial thickness maps with optical coherence tomography.
    Li Y; Chamberlain W; Tan O; Brass R; Weiss JL; Huang D
    J Cataract Refract Surg; 2016 Feb; 42(2):284-95. PubMed ID: 27026454
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Keratoconus diagnosis with optical coherence tomography pachymetry mapping.
    Li Y; Meisler DM; Tang M; Lu AT; Thakrar V; Reiser BJ; Huang D
    Ophthalmology; 2008 Dec; 115(12):2159-66. PubMed ID: 18977536
    [TBL] [Abstract][Full Text] [Related]  

  • 52. The Role of Ocular Response Analyzer in Differentiation of Forme Fruste Keratoconus From Corneal Astigmatism.
    Kirgiz A; Karaman Erdur S; Atalay K; Gurez C
    Eye Contact Lens; 2019 Mar; 45(2):83-87. PubMed ID: 30265255
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Quantitative Evaluation of the Natural Progression of Keratoconus Using Three-Dimensional Optical Coherence Tomography.
    Fujimoto H; Maeda N; Shintani A; Nakagawa T; Fuchihata M; Higashiura R; Nishida K
    Invest Ophthalmol Vis Sci; 2016 Jul; 57(9):OCT169-75. PubMed ID: 27409469
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Comparison of Scheimpflug and swept-source anterior segment optical coherence tomography in normal and keratoconus eyes.
    Ghoreishi SM; Mortazavi SAA; Abtahi ZA; Abtahi MA; Sonbolestan SA; Abtahi SH; Mohammadinia M; Isfahani KN
    Int Ophthalmol; 2017 Aug; 37(4):965-971. PubMed ID: 27671494
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Anatomic Predictive Factors of Acute Corneal Hydrops in Keratoconus: An Optical Coherence Tomography Study.
    Fuentes E; Sandali O; El Sanharawi M; Basli E; Hamiche T; Goemaere I; Borderie V; Bouheraoua N; Laroche L
    Ophthalmology; 2015 Aug; 122(8):1653-9. PubMed ID: 26045363
    [TBL] [Abstract][Full Text] [Related]  

  • 56. [Reliability of corneal tomography after implantation of intracorneal ring segments for keratoconus].
    Matar C; Daas L; Suffo S; Langenbucher A; Seitz B; Eppig T
    Ophthalmologe; 2020 Nov; 117(11):1092-1099. PubMed ID: 32140771
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Corneal hysteresis and corneal resistance factor in keratoectasia: findings using the Reichert ocular response analyzer.
    Kirwan C; O'Malley D; O'Keefe M
    Ophthalmologica; 2008; 222(5):334-7. PubMed ID: 18628636
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Discriminant Value of Custom Ocular Response Analyzer Waveform Derivatives in Forme Fruste Keratoconus.
    Luz A; Lopes B; Hallahan KM; Valbon B; Fontes B; Schor P; Dupps WJ; Ambrósio R
    Am J Ophthalmol; 2016 Apr; 164():14-21. PubMed ID: 26743618
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Relationship between corneal biomechanical parameters and corneal sublayer thickness measured by Corvis ST and UHR-OCT in keratoconus and normal eyes.
    Li Y; Xu Z; Liu Q; Wang Y; Lin K; Xia J; Chen S; Hu L
    Eye Vis (Lond); 2021 Jan; 8(1):2. PubMed ID: 33419485
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Epithelium and Bowman's layer thickness and light scatter in keratoconic cornea evaluated using ultrahigh resolution optical coherence tomography.
    Yadav R; Kottaiyan R; Ahmad K; Yoon G
    J Biomed Opt; 2012 Nov; 17(11):116010. PubMed ID: 23117805
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.