These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

297 related articles for article (PubMed ID: 32661865)

  • 1. Reduction of inappropriate implantable cardioverter-defibrillator therapies using enhanced supraventricular tachycardia discriminators: the ReduceIT study.
    Geller JC; Wöhrle A; Busch M; Elsässer A; Kleemann T; Birkenhauer F; Bramlage P; Veltmann C;
    J Interv Card Electrophysiol; 2021 Aug; 61(2):339-348. PubMed ID: 32661865
    [TBL] [Abstract][Full Text] [Related]  

  • 2. SVT discrimination algorithms significantly reduce the rate of inappropriate therapy in the setting of modern-day delayed high-rate detection programming.
    Cheng A; Auricchio A; Schloss EJ; Kurita T; Sterns LD; Gerritse B; Brown ML; Fagan DH; Lexcen DR; Ellenbogen KA
    J Cardiovasc Electrophysiol; 2019 Dec; 30(12):2877-2884. PubMed ID: 31646695
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Supraventricular arrhythmias in children and young adults with implantable cardioverter defibrillators.
    Love BA; Barrett KS; Alexander ME; Bevilacqua LM; Epstein MR; Triedman JK; Walsh EP; Berul CI
    J Cardiovasc Electrophysiol; 2001 Oct; 12(10):1097-101. PubMed ID: 11699514
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Randomized controlled study of detection enhancements versus rate-only detection to prevent inappropriate therapy in a dual-chamber implantable cardioverter-defibrillator.
    Dorian P; Philippon F; Thibault B; Kimber S; Sterns L; Greene M; Newman D; Gelaznikas R; Barr A;
    Heart Rhythm; 2004 Nov; 1(5):540-7. PubMed ID: 15851216
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Novel ICD Programming and Inappropriate ICD Therapy in CRT-D Versus ICD Patients: A MADIT-RIT Sub-Study.
    Kutyifa V; Daubert JP; Schuger C; Goldenberg I; Klein H; Aktas MK; McNitt S; Stockburger M; Merkely B; Zareba W; Moss AJ
    Circ Arrhythm Electrophysiol; 2016 Jan; 9(1):e001965. PubMed ID: 26743237
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Survival after shock therapy in implantable cardioverter-defibrillator and cardiac resynchronization therapy-defibrillator recipients according to rhythm shocked. The ALTITUDE survival by rhythm study.
    Powell BD; Saxon LA; Boehmer JP; Day JD; Gilliam FR; Heidenreich PA; Jones PW; Rousseau MJ; Hayes DL
    J Am Coll Cardiol; 2013 Oct; 62(18):1674-1679. PubMed ID: 23810882
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Reduced risk for inappropriate implantable cardioverter-defibrillator shocks with dual-chamber therapy compared with single-chamber therapy: results of the randomized OPTION study.
    Kolb C; Sturmer M; Sick P; Reif S; Davy JM; Molon G; Schwab JO; Mantovani G; Dan D; Lennerz C; Borri-Brunetto A; Babuty D
    JACC Heart Fail; 2014 Dec; 2(6):611-9. PubMed ID: 25282033
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Clinical experience with a new detection algorithm for differentiation of supraventricular from ventricular tachycardia in a dual-chamber defibrillator.
    Sinha AM; Stellbrink C; Schuchert A; Mox B; Jordaens L; Lamaison D; Gill J; Kaplan A; Merkely B;
    J Cardiovasc Electrophysiol; 2004 Jun; 15(6):646-52. PubMed ID: 15175058
    [TBL] [Abstract][Full Text] [Related]  

  • 9. QRS Morphology and the Risk of Ventricular Tachyarrhythmia in Cardiac Resynchronization Therapy Recipients.
    Goldenberg I; Aktas MK; Zareba W; Tsu-Chau Huang D; Rosero SZ; Younis A; McNitt S; Stockburger M; Steinberg JS; Buttar RS; Merkely B; Kutyifa V
    JACC Clin Electrophysiol; 2024 Jan; 10(1):16-26. PubMed ID: 38032575
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Mortality reduction in relation to implantable cardioverter defibrillator programming in the Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT).
    Ruwald AC; Schuger C; Moss AJ; Kutyifa V; Olshansky B; Greenberg H; Cannom DS; Estes NA; Ruwald MH; Huang DT; Klein H; McNitt S; Beck CA; Goldstein R; Brown MW; Kautzner J; Shoda M; Wilber D; Zareba W; Daubert JP
    Circ Arrhythm Electrophysiol; 2014 Oct; 7(5):785-92. PubMed ID: 25136077
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reduction of inappropriate ICD therapies in patients with primary prevention of sudden cardiac death: DECREASE study.
    Schwab JO; Bonnemeier H; Kleemann T; Brachmann J; Fischer S; Birkenhauer F; Eberhardt F
    Clin Res Cardiol; 2015 Dec; 104(12):1021-32. PubMed ID: 26002818
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Sex Differences in Inappropriate ICD Device Therapies: MADIT-II and MADIT-CRT.
    Tompkins CM; McNitt S; Polonsky B; Daubert JP; Wang PJ; Moss AJ; Zareba W; Kutyifa V
    J Cardiovasc Electrophysiol; 2017 Jan; 28(1):94-102. PubMed ID: 27696593
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Performance of a dual-chamber implantable defibrillator algorithm for discrimination of ventricular from supraventricular tachycardia.
    Kouakam C; Kacet S; Hazard JR; Ferraci A; Mansour H; Defaye P; Davy JM; Lambiez M;
    Europace; 2004 Jan; 6(1):32-42. PubMed ID: 14697724
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Initial clinical experience with a new arrhythmia detection algorithm in dual chamber implantable cardioverter defibrillators.
    Theuns D; Klootwijk AP; Kimman GP; Szili-Török T; Roelandt JR; Jordaens L
    Europace; 2001 Jul; 3(3):181-6. PubMed ID: 11467458
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Influence of diabetes mellitus on inappropriate and appropriate implantable cardioverter-defibrillator therapy and mortality in the Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT) Trial.
    Ruwald MH; Zareba W; Jons C; Zhang C; Ruwald AC; Olshansky B; McNitt S; Bloch Thomsen PE; Shoda M; Merkely B; Moss AJ; Kutyifa V
    Circulation; 2013 Aug; 128(7):694-701. PubMed ID: 23881862
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reduction of inappropriate anti-tachycardia pacing therapies and shocks by a novel suite of detection algorithms in heart failure patients with cardiac resynchronization therapy defibrillators: a historical comparison of a prospective database.
    Lunati M; Proclemer A; Boriani G; Landolina M; Locati E; Rordorf R; Daleffe E; Ricci RP; Catanzariti D; Tomasi L; Gulizia M; Baccillieri MS; Molon G; Gasparini M;
    Europace; 2016 Sep; 18(9):1391-8. PubMed ID: 26826135
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The impact of atrial fibrillation with rapid ventricular rates and device programming on shocks in 106,513 ICD and CRT-D patients.
    Fischer A; Ousdigian KT; Johnson JW; Gillberg JM; Wilkoff BL
    Heart Rhythm; 2012 Jan; 9(1):24-31. PubMed ID: 21835150
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Outcomes of defibrillator therapy in catecholaminergic polymorphic ventricular tachycardia.
    Roses-Noguer F; Jarman JW; Clague JR; Till J
    Heart Rhythm; 2014 Jan; 11(1):58-66. PubMed ID: 24120999
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Morphology discrimination: a beat-to-beat algorithm for the discrimination of ventricular from supraventricular tachycardia by implantable cardioverter defibrillators.
    Grönefeld GC; Schulte B; Hohnloser SH; Trappe HJ; Korte T; Stellbrink C; Jung W; Meesmann M; Böcker D; Grosse-Meininghaus D; Vogt J;
    Pacing Clin Electrophysiol; 2001 Oct; 24(10):1519-24. PubMed ID: 11707046
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Relationship between age and inappropriate implantable cardioverter-defibrillator therapy in MADIT-RIT (Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy).
    Biton Y; Huang DT; Goldenberg I; Rosero S; Moss AJ; Kutyifa V; McNitt S; Strasberg B; Zareba W; Barsheshet A
    Heart Rhythm; 2016 Apr; 13(4):888-93. PubMed ID: 26711799
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.