These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 32663304)

  • 1. Effects of Occlusal Scheme on All-on-Four Abutments, Screws, and Prostheses: A Three-Dimensional Finite Element Study.
    Türker N; Alkiş HT; Sadowsky SJ; Şebnem Büyükkaplan U
    J Oral Implantol; 2021 Feb; 47(1):18-24. PubMed ID: 32663304
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Finite Element Stress Analysis of Applied Forces to Implants and Supporting Tissues Using the "All-on-Four" Concept with Different Occlusal Schemes.
    Türker N; Büyükkaplan US; Sadowsky SJ; Özarslan MM
    J Prosthodont; 2019 Feb; 28(2):185-194. PubMed ID: 30515911
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Biomechanical Comparison of Different Implant Inclinations and Cantilever Lengths in All-on-4 Treatment Concept by Three-Dimensional Finite Element Analysis.
    Ozan O; Kurtulmus-Yilmaz S
    Int J Oral Maxillofac Implants; 2018; 33(1):64-71. PubMed ID: 29340344
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effects of abutment screw preload in two implant connection systems: A 3D finite element study.
    Jung WK; Lee WS; Kwon HB
    J Prosthet Dent; 2019 Nov; 122(5):474.e1-474.e8. PubMed ID: 31590980
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of occlusal forces on stress distribution in preloaded dental implant screws.
    Alkan I; Sertgöz A; Ekici B
    J Prosthet Dent; 2004 Apr; 91(4):319-25. PubMed ID: 15116032
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of Stress Distribution and Deformation of Four Prosthetic Materials in Full-mouth Rehabilitation with Implants: A Three-dimensional Finite Element Study.
    Chand YB; Mahendra J; Jigeesh N; Mahendra L; Shivasubramanian L; Perika SB
    J Contemp Dent Pract; 2020 Nov; 21(11):1210-1217. PubMed ID: 33850065
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Biomechanics of 3-implant-supported and 4-implant-supported mandibular screw-retained prostheses: A 3D finite element analysis study.
    Elsayyad AA; Abbas NA; AbdelNabi NM; Osman RB
    J Prosthet Dent; 2020 Jul; 124(1):68.e1-68.e10. PubMed ID: 32199642
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Three-Dimensional Finite Element Analysis of the Biomechanical Behaviors of Implants with Different Connections, Lengths, and Diameters Placed in the Maxillary Anterior Region.
    Borie E; Orsi IA; Noritomi PY; Kemmoku DT
    Int J Oral Maxillofac Implants; 2016; 31(1):101-10. PubMed ID: 26478969
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Stresses induced by one piece and two piece dental implants in All-on-4® implant supported prosthesis under simulated lateral occlusal loading: non linear finite element analysis study.
    Mohamed AMA; Askar MG; El Homossany MEB
    BMC Oral Health; 2022 May; 22(1):196. PubMed ID: 35599323
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biomechanical effect of an occlusal device for patients with an implant-supported fixed dental prosthesis under parafunctional loading: A 3D finite element analysis.
    Silva LS; Verri FR; Lemos CAA; Martins CM; Pellizzer EP; de Souza Batista VE
    J Prosthet Dent; 2021 Aug; 126(2):223.e1-223.e8. PubMed ID: 34099274
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Influence of Implant Inclination and Prosthetic Abutment Type on the Biomechanics of Implant-Supported Fixed Partial Dentures.
    Poletto-Neto V; Tretto PHW; Zen BM; Bacchi A; Dos Santos MBF
    J Oral Implantol; 2019 Oct; 45(5):343-350. PubMed ID: 31429636
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Influence of transmucosal height in abutments of single and multiple implant-supported prostheses: a non-linear three-dimensional finite element analysis.
    Borie E; Leal E; Orsi IA; Salamanca C; Dias FJ; Weber B
    Comput Methods Biomech Biomed Engin; 2018 Jan; 21(1):91-97. PubMed ID: 29318899
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of the effect of an offset implant configuration in the posterior maxilla with external hexagon implant platform: A 3-dimensional finite element analysis.
    de Souza Batista VE; Verri FR; Almeida DAF; Santiago Junior JF; Lemos CAA; Pellizzer EP
    J Prosthet Dent; 2017 Sep; 118(3):363-371. PubMed ID: 28222876
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Finite element analysis of implant-supported prosthesis with pontic and cantilever in the posterior maxilla.
    de Souza Batista VE; Verri FR; Almeida DA; Santiago Junior JF; Lemos CA; Pellizzer EP
    Comput Methods Biomech Biomed Engin; 2017 May; 20(6):663-670. PubMed ID: 28349769
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Computational Biomechanical Analysis of Engaging and Nonengaging Abutments for Implant Screw-Retained Fixed Dental Prostheses.
    Savignano R; Soltanzadeh P; Suprono MS
    J Prosthodont; 2021 Aug; 30(7):604-609. PubMed ID: 33196135
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Assessment of the effect of two occlusal concepts for implant-supported fixed prostheses by finite element analysis in patients with bruxism.
    Göre E; Evlioğlu G
    J Oral Implantol; 2014 Feb; 40(1):68-75. PubMed ID: 22242658
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Stress evaluation of different implant lengths on atrophic edentulous mandibles with fixed full-arch implant-supported prosthesis: a finite element analysis.
    Benevides F; Cimões R; Vajgel A; Wilmersdorf RB; Vajgel BCF
    Comput Methods Biomech Biomed Engin; 2021 Mar; 24(4):358-374. PubMed ID: 34121526
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A finite element analysis of two different dental implants: stress distribution in the prosthesis, abutment, implant, and supporting bone.
    Quaresma SE; Cury PR; Sendyk WR; Sendyk C
    J Oral Implantol; 2008; 34(1):1-6. PubMed ID: 18390236
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Stress Distribution on the Prosthetic Screws in the All-on-4 Concept: A Three-Dimensional Finite Element Analysis.
    Oh JH; Kim YS; Lim JY; Choi BH
    J Oral Implantol; 2020 Feb; 46(1):3-12. PubMed ID: 31647687
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of different design of abutment and implant on stress distribution in 2 implants and peripheral bone: A finite element analysis study.
    Kul E; Korkmaz İH
    J Prosthet Dent; 2021 Nov; 126(5):664.e1-664.e9. PubMed ID: 33573834
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.