264 related articles for article (PubMed ID: 32672662)
1. Evaluation of insertion torque and surface integrity of zirconia-coated titanium mini screw implants.
Giri M; Sabapathy K; Govindasamy B; Rajamurugan H
J World Fed Orthod; 2020 Mar; 9(1):13-17. PubMed ID: 32672662
[TBL] [Abstract][Full Text] [Related]
2. Biomechanical Evaluation of Nano-Zirconia Coatings on Ti-6Al-7Nb Implant Screws in Rabbit Tibias.
Hamad TI; Fatalla AA; Waheed AS; Azzawi ZGM; Cao YG; Song K
Curr Med Sci; 2018 Jun; 38(3):530-537. PubMed ID: 30074223
[TBL] [Abstract][Full Text] [Related]
3. Peri-implant bone formations around (Ti,Zr)O(2) -coated zirconia implants with different surface roughness.
Chung SH; Kim HK; Shon WJ; Park YS
J Clin Periodontol; 2013 Apr; 40(4):404-11. PubMed ID: 23425208
[TBL] [Abstract][Full Text] [Related]
4. Bone tissue responses to surface-modified zirconia implants: A histomorphometric and removal torque study in the rabbit.
Sennerby L; Dasmah A; Larsson B; Iverhed M
Clin Implant Dent Relat Res; 2005; 7 Suppl 1():S13-20. PubMed ID: 16137083
[TBL] [Abstract][Full Text] [Related]
5. Peak insertion torque values of five mini-implant systems under different insertion loads.
Quraishi E; Sherriff M; Bister D
J Orthod; 2014 Jun; 41(2):102-9. PubMed ID: 24521745
[TBL] [Abstract][Full Text] [Related]
6. Screw stability of CAD-CAM titanium and zirconia abutments on different implants: An in vitro study.
Yilmaz B; Çakmak G; Batak B; Johnston WM
Clin Implant Dent Relat Res; 2021 Jun; 23(3):373-379. PubMed ID: 33938119
[TBL] [Abstract][Full Text] [Related]
7. Implant stability and marginal bone level of microgrooved zirconia dental implants: A 3-month experimental study on dogs.
Delgado-Ruiz RA; Marković A; Calvo-Guirado JL; Lazić Z; Piattelli A; Boticelli D; Maté-Sánchez JE; Negri B; Ramírez-Fernández MP; Mišić T
Vojnosanit Pregl; 2014 May; 71(5):451-61. PubMed ID: 26137710
[TBL] [Abstract][Full Text] [Related]
8. Titanium and zirconium release from titanium- and zirconia implants in mini pig maxillae and their toxicity in vitro.
He X; Reichl FX; Milz S; Michalke B; Wu X; Sprecher CM; Yang Y; Gahlert M; Röhling S; Kniha H; Hickel R; Högg C
Dent Mater; 2020 Mar; 36(3):402-412. PubMed ID: 31992485
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of the sealing capability of implants to titanium and zirconia abutments against Porphyromonas gingivalis, Prevotella intermedia, and Fusobacterium nucleatum under different screw torque values.
Smith NA; Turkyilmaz I
J Prosthet Dent; 2014 Sep; 112(3):561-7. PubMed ID: 24656409
[TBL] [Abstract][Full Text] [Related]
10. Mechanical evaluation of orthodontic mini-implants of different lengths.
Pithon MM; Figueiredo DS; Oliveira DD
J Oral Maxillofac Surg; 2013 Mar; 71(3):479-86. PubMed ID: 23273488
[TBL] [Abstract][Full Text] [Related]
11. [Application of plasma sprayed zirconia coating in dental implant: study in implant].
Huang ZF; Wang ZF; Li CH; Hao D; Lan J
Zhonghua Kou Qiang Yi Xue Za Zhi; 2018 Apr; 53(4):264-270. PubMed ID: 29690698
[No Abstract] [Full Text] [Related]
12. Distribution and amount of stresses caused by insertion or removal of orthodontic miniscrews into the maxillary bone: A finite element analysis.
Ghorbanyjavadpour F; Kazemi P; Moradinezhad M; Rakhshan V
Int Orthod; 2019 Dec; 17(4):758-768. PubMed ID: 31494087
[TBL] [Abstract][Full Text] [Related]
13. A torque removal study on the primary stability of orthodontic titanium screw mini-implants in the cortical bone of dog femurs.
Okazaki J; Komasa Y; Sakai D; Kamada A; Ikeo T; Toda I; Suwa F; Inoue M; Etoh T
Int J Oral Maxillofac Surg; 2008 Jul; 37(7):647-50. PubMed ID: 18554870
[TBL] [Abstract][Full Text] [Related]
14. Fracture resistance of orthodontic mini-implants: a biomechanical in vitro study.
Wilmes B; Panayotidis A; Drescher D
Eur J Orthod; 2011 Aug; 33(4):396-401. PubMed ID: 21310766
[TBL] [Abstract][Full Text] [Related]
15. A comparative evaluation of ion release from different commercially-available orthodontic mini-implants - an in-vitro study.
Ananthanarayanan V; Padmanabhan S; Chitharanjan AB
Aust Orthod J; 2016 Nov; 32(2):165-174. PubMed ID: 29509341
[TBL] [Abstract][Full Text] [Related]
16. Analysis of dimensional changes in the screw and the surface topography at the interface of a titanium screw and a zirconia abutment under cyclic loading: an in vitro study.
Dhingra A; Weiner S; Luke AC; Ricci JL
Int J Oral Maxillofac Implants; 2013; 28(3):661-9. PubMed ID: 23748295
[TBL] [Abstract][Full Text] [Related]
17. Histomorphometric and removal torque analysis for TiO2-blasted titanium implants. An experimental study on dogs.
Gotfredsen K; Nimb L; Hjörting-Hansen E; Jensen JS; Holmén A
Clin Oral Implants Res; 1992 Jun; 3(2):77-84. PubMed ID: 15900672
[TBL] [Abstract][Full Text] [Related]
18. Wear and Corrosion Interactions at the Titanium/Zirconia Interface: Dental Implant Application.
Sikora CL; Alfaro MF; Yuan JC; Barao VA; Sukotjo C; Mathew MT
J Prosthodont; 2018 Dec; 27(9):842-852. PubMed ID: 29521461
[TBL] [Abstract][Full Text] [Related]
19. Effect of macrogeometry and bone type on insertion torque, primary stability, surface topography damage and titanium release of dental implants during surgical insertion into artificial bone.
Silva GAF; Faot F; Possebon APDR; da Silva WJ; Del Bel Cury AA
J Mech Behav Biomed Mater; 2021 Jul; 119():104515. PubMed ID: 33932754
[TBL] [Abstract][Full Text] [Related]
20. Analysis of Removal Torque of Injection Molded Zirconia Implants; An Experimental Study on Beagles.
Oh GJ; Ban JS; Lim HP; Yun KD; Lee KM; Vang MS; Yang HS; Kang SS; Shin JH; Kim GH; Ji MK; Park SW; Fisher JG
J Nanosci Nanotechnol; 2015 Jan; 15(1):339-41. PubMed ID: 26328356
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]