These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 32688329)

  • 21. Evaluation of Performance Characteristics of the Aptima HIV-1 Quant Dx Assay for Detection and Quantitation of Human Immunodeficiency Virus Type 1 in Plasma and Cervicovaginal Lavage Samples.
    Sam SS; Kurpewski JR; Cu-Uvin S; Caliendo AM
    J Clin Microbiol; 2016 Apr; 54(4):1036-41. PubMed ID: 26842702
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Performance Evaluation of the New HIV-1 Quantification Assay, Xpert HIV-1 Viral Load, on a Wide Panel of HIV-1 Variants.
    Gueudin M; Baron A; Alessandri-Gradt E; Lemée V; Mourez T; Etienne M; Plantier JC
    J Acquir Immune Defic Syndr; 2016 Aug; 72(5):521-6. PubMed ID: 27007866
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Evaluating the aptima HIV-1 quant Dx, HCV quant Dx and HBV quant assays against the Abbott HIV-1, HCV and HBV RealTime assays.
    May S; Adamska E; Tang JW
    J Clin Virol; 2018 Sep; 106():7-10. PubMed ID: 30007139
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Investigating utilising the Alinity m platform to detect hepatitis C virus RNA in dried blood spot samples.
    Goldstein EJ; Shepherd SJ; Gunson RN
    J Clin Virol; 2020 Nov; 132():104647. PubMed ID: 32979769
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Analytical characteristics and comparative evaluation of Aptima HIV-1 Quant Dx assay with Ampliprep/COBAS TaqMan HIV-1 test v2.0.
    Hatzakis A; Papachristou H; Nair SJ; Fortunko J; Foote T; Kim H; Peling TL; Worlock AJ
    Virol J; 2016 Oct; 13(1):176. PubMed ID: 27769309
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Field evaluation of an open and polyvalent universal HIV-1/SIVcpz/SIVgor quantitative RT-PCR assay for HIV-1 viral load monitoring in comparison to Abbott RealTime HIV-1 in Cameroon.
    Guichet E; Aghokeng A; Eymard-Duvernay S; Vidal N; Ayouba A; Mpoudi Ngole E; Delaporte E; Ciaffi L; Peeters M
    J Virol Methods; 2016 Nov; 237():121-126. PubMed ID: 27609535
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Evaluation of the new LCx HIV RNA quantitative assay: comparison with the Cobas Amplicor HIV Monitor assay.
    Berger A; Rabenau HF; Stief A; Troonen H; Doerr HW
    Med Microbiol Immunol; 2001 Dec; 190(3):129-34. PubMed ID: 11827201
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Performance evaluation of the Aptima HIV-1 RNA Quant assay on the Panther system using the standard and dilution protocols.
    Rossetti R; Smith T; Luo W; Taussig J; Valentine-Graves M; Sullivan P; Ingersoll JM; Kraft CS; Ethridge S; Wesolowski L; Delaney KP; Owen SM; Johnson JA; Masciotra S
    J Clin Virol; 2020 Aug; 129():104479. PubMed ID: 32531665
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Evaluation of performance across the dynamic range of the Abbott RealTime HIV-1 assay as compared to VERSANT HIV-1 RNA 3.0 and AMPLICOR HIV-1 MONITOR v1.5 using serial dilutions of 39 group M and O viruses.
    Swanson P; Huang S; Abravaya K; de Mendoza C; Soriano V; Devare SG; Hackett J
    J Virol Methods; 2007 Apr; 141(1):49-57. PubMed ID: 17184853
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Multicenter study of the LCx HIV RNA quantitative assay--a new competitive reverse transcriptase-PCR which targets pol genomic region of HIV-1 for the measurement of type B, non-type B and group O HIV-1 RNA.
    Troonen H; Grey H; Michel G
    Clin Chem Lab Med; 2002 Jul; 40(7):698-704. PubMed ID: 12241017
    [TBL] [Abstract][Full Text] [Related]  

  • 31. High correlation between the Roche COBAS® AmpliPrep/COBAS® TaqMan® HIV-1, v2.0 and the Abbott m2000 RealTime HIV-1 assays for quantification of viral load in HIV-1 B and non-B subtypes.
    Karasi JC; Dziezuk F; Quennery L; Förster S; Reischl U; Colucci G; Schoener D; Seguin-Devaux C; Schmit JC
    J Clin Virol; 2011 Nov; 52(3):181-6. PubMed ID: 21813320
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Performance of point-of-care Xpert HIV-1 plasma viral load assay at a tertiary HIV care centre in Southern India.
    Swathirajan CR; Vignesh R; Boobalan J; Solomon SS; Saravanan S; Balakrishnan P
    J Med Microbiol; 2017 Oct; 66(10):1379-1382. PubMed ID: 28901908
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Clinical comparison of three SARS-CoV-2 nucleic acid amplification tests for routine diagnostic testing.
    Garmatiuk T; Gränitz-Trisko C; Sochor-Geischläger C; Polsterer T; Caselotto F; Willitsch L; Reinhardt B; Huf W
    Heliyon; 2023 Nov; 9(11):e22112. PubMed ID: 38034696
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Performance evaluation of the Aptima
    Garbuglia AR; Bibbò A; Sciamanna R; Pisciotta M; Capobianchi MR
    J Clin Virol; 2017 Jul; 92():1-6. PubMed ID: 28475925
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Clinical evaluation of the automated Abbott RealTime SARS-CoV-2, Alinity m SARS-CoV-2, and Alinity m Resp-4-Plex assays.
    Ehret R; Breuer S; Dhein J; Reinhardt B; Obermeier M
    J Virol Methods; 2022 Jan; 299():114338. PubMed ID: 34695479
    [TBL] [Abstract][Full Text] [Related]  

  • 36. ARCHITECT® HIV Ag/Ab Combo assay: correlation of HIV-1 p24 antigen sensitivity and RNA viral load using genetically diverse virus isolates.
    Brennan CA; Yamaguchi J; Vallari A; Swanson P; Hackett JR
    J Clin Virol; 2013 Jun; 57(2):169-72. PubMed ID: 23485348
    [TBL] [Abstract][Full Text] [Related]  

  • 37. An in-house assay for BK polyomavirus quantification using the Abbott m2000 RealTime system.
    Muldrew KL; Lovett JL
    J Med Microbiol; 2013 Nov; 62(Pt 11):1714-1720. PubMed ID: 23924663
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Comparative RNA quantification of HIV-1 group M and non-M with the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 v2.0 and Abbott Real-Time HIV-1 PCR assays.
    Sire JM; Vray M; Merzouk M; Plantier JC; Pavie J; Maylin S; Timsit J; Lascoux-Combe C; Molina JM; Simon F; Delaugerre C
    J Acquir Immune Defic Syndr; 2011 Mar; 56(3):239-43. PubMed ID: 21164353
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Comparative evaluation of the Cobas Amplicor HIV-1 Monitor Ultrasensitive Test, the new Cobas AmpliPrep/Cobas Amplicor HIV-1 Monitor Ultrasensitive Test and the Versant HIV RNA 3.0 assays for quantitation of HIV-1 RNA in plasma samples.
    Berger A; Scherzed L; Stürmer M; Preiser W; Doerr HW; Rabenau HF
    J Clin Virol; 2005 May; 33(1):43-51. PubMed ID: 15797364
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Performance characteristics of the QUANTIPLEX HIV-1 RNA 3.0 assay for detection and quantitation of human immunodeficiency virus type 1 RNA in plasma.
    Erice A; Brambilla D; Bremer J; Jackson JB; Kokka R; Yen-Lieberman B; Coombs RW
    J Clin Microbiol; 2000 Aug; 38(8):2837-45. PubMed ID: 10921936
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.