BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 32693440)

  • 1. Incidence and Risk Factors for Implant Failure in Spinal Metastasis Surgery.
    Wong YC; Chau WWJ; Kwok KO; Law SW
    Asian Spine J; 2020 Dec; 14(6):878-885. PubMed ID: 32693440
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Risk factors for implant removal after spinal surgical site infection.
    Tsubouchi N; Fujibayashi S; Otsuki B; Izeki M; Kimura H; Ota M; Sakamoto T; Uchikoshi A; Matsuda S
    Eur Spine J; 2018 Oct; 27(10):2481-2490. PubMed ID: 28913559
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Postoperative wound infection after posterior spinal instrumentation: analysis of long-term treatment outcomes.
    Chen SH; Lee CH; Huang KC; Hsieh PH; Tsai SY
    Eur Spine J; 2015 Mar; 24(3):561-70. PubMed ID: 25351841
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Symptomatic Construct Failure after Metastatic Spine Tumor Surgery.
    Kumar N; Patel R; Tan JH; Song J; Pandita N; Hey DHW; Lau LL; Liu G; Thambiah J; Wong HK
    Asian Spine J; 2021 Aug; 15(4):481-490. PubMed ID: 33108849
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Loss of sagittal plane correction after removal of spinal implants.
    Deckey JE; Court C; Bradford DS
    Spine (Phila Pa 1976); 2000 Oct; 25(19):2453-60. PubMed ID: 11013496
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Avoiding early complications and reoperation during occipitocervical fusion in pediatric patients.
    Mazur MD; Sivakumar W; Riva-Cambrin J; Jones J; Brockmeyer DL
    J Neurosurg Pediatr; 2014 Nov; 14(5):465-75. PubMed ID: 25171720
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Reoperation after in-theater combat spine surgery.
    Formby PM; Wagner SC; Kang DG; Van Blarcum GS; Pisano AJ; Lehman RA
    Spine J; 2016 Mar; 16(3):329-34. PubMed ID: 26639623
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The incidence and patterns of hardware failure after separation surgery in patients with spinal metastatic tumors.
    Amankulor NM; Xu R; Iorgulescu JB; Chapman T; Reiner AS; Riedel E; Lis E; Yamada Y; Bilsky M; Laufer I
    Spine J; 2014 Sep; 14(9):1850-9. PubMed ID: 24216397
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Failure of attempted implant retention in spinal deformity delayed surgical site infections.
    Hedequist D; Haugen A; Hresko T; Emans J
    Spine (Phila Pa 1976); 2009 Jan; 34(1):60-4. PubMed ID: 19077923
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Spinal surgery in patients with Parkinson's disease: construct failure and progressive deformity.
    Babat LB; McLain RF; Bingaman W; Kalfas I; Young P; Rufo-Smith C
    Spine (Phila Pa 1976); 2004 Sep; 29(18):2006-12. PubMed ID: 15371701
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Risk factors for construct/implant related complications following primary posterior hemivertebra resection: Study on 116 cases with more than 2 years' follow-up in one medical center.
    Guo J; Zhang J; Wang S; Wang H; Zhang Y; Yang Y; Yang X; Zhao L
    BMC Musculoskelet Disord; 2016 Sep; 17(1):380. PubMed ID: 27589864
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Basic concepts in metal work failure after metastatic spine tumour surgery.
    Kumar N; Patel R; Wadhwa AC; Kumar A; Milavec HM; Sonawane D; Singh G; Benneker LM
    Eur Spine J; 2018 Apr; 27(4):806-814. PubMed ID: 29204734
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Asymptomatic Construct Failure after Metastatic Spine Tumor Surgery: A New Entity or a Continuum with Symptomatic Failure?
    Kumar N; Patel R; Tan BWL; Tan JH; Pandita N; Sonawane D; Lopez KG; Wai KL; Hey HWD; Kumar A; Liu G
    Asian Spine J; 2021 Oct; 15(5):636-649. PubMed ID: 33108848
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Incidence and Predictors of Hardware Failure After Instrumentation for Spine Metastasis: A Single-Institutional Series.
    Longo M; De la Garza Ramos R; Gelfand Y; Echt M; Kinon MD; Yassari R
    World Neurosurg; 2019 May; 125():e1170-e1175. PubMed ID: 30794977
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison between 4.0-mm stainless steel and 4.75-mm titanium alloy single-rod spinal instrumentation for anterior thoracoscopic scoliosis surgery.
    Yoon SH; Ugrinow VL; Upasani VV; Pawelek JB; Newton PO
    Spine (Phila Pa 1976); 2008 Sep; 33(20):2173-8. PubMed ID: 18794758
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Analysis of reoperations after surgical treatment of degenerative cervical spine disorders: a report on 900 cases.
    Greiner-Perth R; Allam Y; El-Saghir H; Röhl F; Franke J; Böhm H
    Cent Eur Neurosurg; 2009 Feb; 70(1):3-8. PubMed ID: 19191203
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Incidence of complete spinal instrumentation removal following surgery for spinal deformity: a 22-year single institution study.
    Abola MV; Hardesty CK; Knapik DM; Poe-Kochert C; Son-Hing JP; Thompson GH
    J Pediatr Orthop B; 2019 Jul; 28(4):380-384. PubMed ID: 31136374
    [TBL] [Abstract][Full Text] [Related]  

  • 18. What Factors Are Associated With Implant Breakage and Revision After Intramedullary Nailing for Femoral Metastases?
    Willeumier JJ; Kaynak M; van der Zwaal P; Meylaerts SAG; Mathijssen NMC; Jutte PC; Tsagozis P; Wedin R; van de Sande MAJ; Fiocco M; Dijkstra PDS
    Clin Orthop Relat Res; 2018 Sep; 476(9):1823-1833. PubMed ID: 30566108
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Implant survival after deep infection of an instrumented spinal fusion.
    Núñez-Pereira S; Pellisé F; Rodríguez-Pardo D; Pigrau C; Bagó J; Villanueva C; Cáceres E
    Bone Joint J; 2013 Aug; 95-B(8):1121-6. PubMed ID: 23908430
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Postoperative spinal wound infection: a review of 2,391 consecutive index procedures.
    Weinstein MA; McCabe JP; Cammisa FP
    J Spinal Disord; 2000 Oct; 13(5):422-6. PubMed ID: 11052352
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.